Measurement of the homogeneous velocity of inclined oil-in-water flows using a resistance cross correlation flow meter

被引:29
|
作者
Lucas, GP [1 ]
Jin, ND
机构
[1] Univ Huddersfield, Huddersfield HD1 3DH, W Yorkshire, England
[2] Daqing Petr Inst, Anda 151400, Peoples R China
关键词
intermittent Kelvin-Helmholtz structures; cross correlation velocity measurement; inclined oil-in-water flows;
D O I
10.1088/0957-0233/12/9/320
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes an investigation into a cross correlation flow meter, using 'global' resistance sensors, for measuring the homogeneous velocity of inclined oil-in-water flows. The cross correlation flow meter measures the axial propagation speed U-cc of intermittent Kelvin-Helmholtz structures in the flow. It is shown that, for inclination angles in the range 15 degrees to 45 degrees from the vertical, the measured velocity U-cc is dependent only upon the homogeneous velocity and is independent both of the inclination angle theta of the flow and of the oil volume fraction alpha. For an angle of inclination to the vertical of 60 degrees, U-cc is dependent both upon the homogeneous velocity and upon the oil volume fraction alpha. For inclination angles in the range 15 degrees less than or equal to theta less than or equal to 45 degrees predictions of the homogeneous velocity were obtained using only the measured cross correlation velocity U-cc. For 15 degrees less than or equal to theta less than or equal to 45 degrees, the mean percentage error (E) over bar in the predicted homogeneous velocity was 0.1% whilst the standard deviation (S) over bar of the percentage error in the predicted values of the homogeneous velocity was found to be 4.0%. For the angle of inclination to the vertical of 60 degrees predictions of the homogeneous velocity were obtained using the measured cross correlation velocity U-cc and the measured oil volume fraction alpha. For theta = 60 degrees the mean percentage error (E) over bar in the predicted homogeneous velocity was -0.39% whilst the standard deviation (S) over bar of the percentage error in the predicted values of the homogeneous velocity was 5.2%.
引用
收藏
页码:1529 / 1537
页数:9
相关论文
共 50 条
  • [21] Measurement of water holdup in vertical upward high water-cut oil-in-water flows using a high frequency sensor
    Ma, Jing
    Jin, Ning-De
    Wang, Da-Yang
    Liu, Dong-Yang
    Liu, Wei-Xin
    SENSORS AND ACTUATORS A-PHYSICAL, 2019, 289 : 165 - 179
  • [22] Velocity and turbulence measurements of oil-water flow in horizontal and slightly inclined pipes using PIV
    Kumara, W. A. S.
    Halvorsen, B. M.
    Melaaen, M. C.
    COMPUTATIONAL METHODS IN MULTIPHASE FLOW V, 2009, : 277 - 292
  • [23] Flow Velocity Measurement by Cross-correlation with Tailored Modulation
    Cui, Ziqiang
    Wang, Huaxiang
    Yin, Wuliang
    Yang, Wuqiang
    2015 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2015, : 1906 - 1909
  • [24] Cross-flow microfiltration of oil-in-water emulsions using low cost ceramic membranes
    Vasanth, D.
    Pugazhenthi, G.
    Uppaluri, R.
    DESALINATION, 2013, 320 : 86 - 95
  • [25] Reconstruction of velocity profiles in axisymmetric and asymmetric flows using an electromagnetic flow meter
    Kollar, Laszlo E.
    Lucas, Gary P.
    Meng, Yiqing
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2015, 26 (05) : 1 - 12
  • [26] Velocity and Flow-rate Measurement in Single-phase Flows by Cross-correlation Methods.
    Koppermann, Claus
    Fortschritt-Berichte der VDI-Zeitschriften, Reihe 8: Mess- , Steuerungs-und Regelungstechnik, 1983, (63):
  • [27] Cross Correlation Velocity of Oil-water Two-Phase Flow by a Dual-Plane Electrical Resistance Tomography System
    Tan, Chao
    Dong, Feng
    2010 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE I2MTC 2010, PROCEEDINGS, 2010,
  • [28] Measurement of Interfacial Characteristics of Horizontal and Inclined Oil-Water Flows by Using Wire-Mesh Sensor
    Zhai, Lusheng
    Qiao, Jiawei
    Wang, Wenhao
    Wang, Yuqing
    ENERGIES, 2022, 15 (18)
  • [29] A two-phase flow meter for determining water and solids volumetric flow rates in stratified, inclined solids-in-water flows
    Muhamedsalih, Y.
    Lucas, G. P.
    Meng, Y. Q.
    FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 45 : 207 - 217
  • [30] A Modified Adaptive Cross Correlation Method for Flow Rate Measurement of High-Water-Cut Oil-Water Flow Using Planar Flowmeter
    Zhang, Xiaokai
    Sun, Jiangtao
    Hu, Jinhai
    Liu, Xiaolei
    Liu, Xingbin
    Xie, Ronghua
    Cai, Bing
    Sun, Liang
    Xu, Lijun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71