Barley (Hordeum vulgare L. cv Doriru) leaf samples were collected from a field comprising three plots, plot F chemical fertilizer treated, plot S receiving sewage sludge and sawdust mixed compost, and plot H receiving sewage sludge and rice husk mixed compost. Relative concentrations of selected elements, potassium (K), calcium (Ca), and chloride (C1) of young, mature, and old barley leaves were determined by microscopic energy dispersing X-ray fluorescence (EDXRF). The objective of this investigation was to verify the applicability of EDXRF for rapid nutrient element diagnosis of plants. Typically whole leaves were washed in deionized-distilled water and dried by ironing for analysis. Intact dried barley leaf sample irradiation was accomplished with X-rays obtained from an X-ray tube focused on an area <100 mu m of the respective sample specimen surface. The EDXRF provided sufficient sensitivity for relative concentrations of K, Ca, and Cl. Element content data of all the elements investigated, specifically K, resulted in adequate plant nutrient element values to diagnose K insufficiency in barley leaves taken from plants in the sewage sludge receiving plots. Potassium was more densely accumulated in the new leaf than in mature and old leaves in case of plants from the S and H plots. In contrast, such K accumulation was more dense in old and mature leaves than young leaves in case of plants from the F plot. However, Cl and Ca coupling in barley leaves from all of the F, S, and H plots had shown the similar pattern of distribution and followed the order: old > mature > young. Therefore, EDXRF can be an easy, rapid, and practical method for diagnosing the elemental content of plant tissues and thereby help to aid plant growth and development through timely supplements of the required element(s).
引用
收藏
页码:229 / 235
页数:7
相关论文
共 50 条
  • [31] Position dispersive X-ray fluorescence
    Webster J.L.V.
    Mcllquham J.D.
    Ganly B.
    Radiat. Phys. Chem., 2022,
  • [32] ENERGY DISPERSIVE-X-RAY FLUORESCENCE ANALYSIS OF CHLORIDE IN REFORMING CATALYSTS
    SINGH, RP
    KHATRI, RP
    PAMBID, ER
    ABBAS, NM
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1990, 142 (02): : 499 - 504
  • [33] Energy-dispersive vs wavelength-dispersive X-ray fluorescence spectrometry
    Brill, M
    METALL, 1996, 50 (7-8): : 504 - 511
  • [34] Rapid quantification of iron, copper and zinc in food premixes using energy dispersive X-ray fluorescence
    Perring, L
    Andrey, D
    Basic-Dvorzak, M
    Hammer, D
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2005, 18 (07) : 655 - 663
  • [35] Determination of calcium and iodine in gall bladder stone using energy dispersive X-ray fluorescence spectrometry
    Ekinci, N
    Sahin, Y
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2002, 57 (01) : 167 - 171
  • [36] X-ray fluorescence and energy dispersive x-ray diffraction for the quantification of elemental concentrations in breast tissue
    Geraki, K
    Farquharson, MJ
    Bradley, DA
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (01): : 99 - 110
  • [37] Determination of potassium content in potassium perchlorate used for fireworks and firecrackers based on Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF)
    Wu Jun-yi
    Xiao Huan-xin
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND COMPUTING TECHNOLOGY (ICMMCT 2017), 2017, 126 : 54 - 58
  • [38] Determination of potassium content in potassium chlorate used for fireworks and firecrackers based on Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF)
    Wu Jun-yi
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND COMPUTING TECHNOLOGY (ICMMCT 2017), 2017, 126 : 69 - 73
  • [39] Determination of potassium content in potassium nitrate used for fireworks and firecrackers based on Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF)
    Wu Jun-yi
    PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND COMPUTING TECHNOLOGY (ICMMCT 2017), 2017, 126 : 79 - 83
  • [40] The suppression of fluorescence peaks in energy-dispersive X-ray diffraction
    Hansford, G. M.
    Turner, S. M. R.
    Staab, D.
    Vernon, D.
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2014, 47 : 1708 - 1715