Comparison between GC-TCD and GC-FID for the determination of propane in gas mixture

被引:13
|
作者
Budiman, Harry [1 ]
Nuryatini [1 ]
Zuas, Oman [1 ]
机构
[1] Kawasan PUSPIPTEK, Indonesian Inst Sci LIPI, Res Ctr Chem, Gas Anal Lab GasAL, Serpong 15314, Banten, Indonesia
关键词
propane; gas chromatography; thermal conductivity detector (TCD); flame ionization detector (FID); QUALITY; TRENDS;
D O I
10.1016/j.proche.2015.12.080
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method comparison between gas chromatography-thermal conductivity detector (GC-TCD) and chromatography-flame ionization detector (GC-FID) for the analysis of propane (C3H8) are reported in this study. To achieve the study purpose for producing valid and reliable result, the method comparison process was conducted by investigating several keys of analytical parameter of both GC-TCD and GC-FID method including method sensitivity, precision, accuracy, and method linearity. Investigation of the GC's parameter were conducted by analyzing the C3H8 (% mol/mol) in nitrogen (N-2) balance (known as C3H8 certified reference material). The results show that the GC-FID method was found to display more sensitive, precise, and accurate than GC-TCD method for the analysis of C3H8. The sensitivity of the GC-FID are 66 times higher than GC-TCD method. In addition, the GC-FID exhibits a wider linear range (0.161-2.18 %mol/mol) than the GC-TCD method (0.242 - 2.18 %mol/mol). (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 50 条
  • [21] Comparison of the Determination of Eight Cholesterol Oxides in Dry-Cured Shoulder by GC-FID, GC-MS, and GC Tandem Mass Spectrometry
    Clariana, Maria
    Diaz, Isabel
    Sarraga, Carmen
    Garcia-Regueiro, Jose A.
    FOOD ANALYTICAL METHODS, 2011, 4 (04) : 465 - 474
  • [22] Rapid method for determination of biogas composition by gas chromatography coupled to a thermal conductivity detector (GC-TCD)
    Araujo, Matheus N.
    Vargas, Sarah R.
    Soares, Lais A.
    Trindade, Liliane F.
    Fuess, Lucas T.
    Adorno, Maria A. T.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2023, 104 (20) : 8690 - 8707
  • [23] Determination of Polycyclic Aromatic Hydrocarbons in Coal from the Kuznetsk Coal Basin by Means of GC/MS and GC/GC-FID
    Zhuravleva, E. V.
    Zhuravleva, N., V
    Mikhaylova, E. S.
    Ismagilov, Z. R.
    Shashkov, M. V.
    Dolgushev, P. A.
    EURASIAN CHEMICO-TECHNOLOGICAL JOURNAL, 2022, 24 (02) : 103 - 114
  • [24] Determination of Trace Levels of Fatty Acid Methyl Esters in Aviation Fuel by GC x GC-FID and Comparison with the Reference GC-MS Method
    Lissitsyna, Kristina
    Huertas, Sonia
    Morales, Rocio
    Carlos Quintero, Luis
    Maria Polo, Luis
    CHROMATOGRAPHIA, 2012, 75 (21-22) : 1319 - 1325
  • [25] Middle distillates hydrogen content via GC x GC-FID
    Vozka, Petr
    Mo, Huaping
    Simacek, Pavel
    Kilaz, Gozdem
    TALANTA, 2018, 186 : 140 - 146
  • [26] DEVELOPMENT AND VALIDATION OF A GC-FID ASSAY FOR DETERMINATION OF FLUVASTATIN IN PHARMACEUTICAL PREPARATIONS
    Aslan, Serap Saglik
    Sagirli, Olcay
    Ersoy, Lale
    QUIMICA NOVA, 2009, 32 (09): : 2347 - 2350
  • [27] Electrolyzer-operated gas-cylinder-free GC-FID
    Frishman, G
    Tzanani, N
    Amirav, A
    FIELD ANALYTICAL CHEMISTRY AND TECHNOLOGY, 2001, 5 (03): : 107 - 115
  • [28] Determination of Tramadol by Capillary GC-FID and a study of postmortem distribution in rats
    Man Liang
    Na Zheng
    Cai Xiangyang
    Liu Liang
    Liu Yan
    Jin Ming
    ROMANIAN JOURNAL OF LEGAL MEDICINE, 2011, 19 (01): : 45 - 50
  • [29] Determination of Camphor and Borneol in Flos Chrysanthemi Indici by UAE and GC-FID
    Ye, Qing
    Deng, Chunhui
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2009, 47 (04) : 287 - 290
  • [30] Method for determination of fatty acids in bovine colostrum using GC-FID
    Yurchenko, S.
    Sats, A.
    Poikalainen, V.
    Karus, A.
    FOOD CHEMISTRY, 2016, 212 : 117 - 122