Comparison between GC-TCD and GC-FID for the determination of propane in gas mixture

被引:13
|
作者
Budiman, Harry [1 ]
Nuryatini [1 ]
Zuas, Oman [1 ]
机构
[1] Kawasan PUSPIPTEK, Indonesian Inst Sci LIPI, Res Ctr Chem, Gas Anal Lab GasAL, Serpong 15314, Banten, Indonesia
关键词
propane; gas chromatography; thermal conductivity detector (TCD); flame ionization detector (FID); QUALITY; TRENDS;
D O I
10.1016/j.proche.2015.12.080
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A method comparison between gas chromatography-thermal conductivity detector (GC-TCD) and chromatography-flame ionization detector (GC-FID) for the analysis of propane (C3H8) are reported in this study. To achieve the study purpose for producing valid and reliable result, the method comparison process was conducted by investigating several keys of analytical parameter of both GC-TCD and GC-FID method including method sensitivity, precision, accuracy, and method linearity. Investigation of the GC's parameter were conducted by analyzing the C3H8 (% mol/mol) in nitrogen (N-2) balance (known as C3H8 certified reference material). The results show that the GC-FID method was found to display more sensitive, precise, and accurate than GC-TCD method for the analysis of C3H8. The sensitivity of the GC-FID are 66 times higher than GC-TCD method. In addition, the GC-FID exhibits a wider linear range (0.161-2.18 %mol/mol) than the GC-TCD method (0.242 - 2.18 %mol/mol). (C) 2015 Published by Elsevier B.V.
引用
收藏
页码:465 / 472
页数:8
相关论文
共 50 条
  • [1] Sensitivity comparison of GC-MS and GC-FID/ECD
    Salske, Shawn
    Molter, Kent
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253
  • [2] Determination of Residual Solvents in Perampanel by GC-FID
    Tang, Lu
    Liu, Xuyan
    Wang, Weiwei
    Wang, Wei
    Ni, Feng
    Li, Jianqi
    Chinese Journal of Pharmaceuticals, 2023, 54 (11) : 1660 - 1662
  • [3] CAPILLARY GC-FID AND GC-MS DETERMINATION OF ETHYLDICHLOROSILANE IN METHYLCHLOROSILANES
    DUDDING, GF
    SORENSON, GT
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1980, 18 (12) : 670 - 673
  • [4] Comparison of Methylation Methods for the Determination of Fatty Acids in Meat by GC-FID
    Ferreira, Cintia S. R.
    Santos, Patricia D. S.
    Sinosaki, Nayane B. M.
    Senes, Carlos E. R.
    Visentainer, Jesui V.
    Santos, Oscar O.
    REVISTA VIRTUAL DE QUIMICA, 2020, 12 (06) : 1575 - 1585
  • [5] Determination of jet fuel system icing inhibitor by GC x GC-FID
    Vozka, Petr
    Kilaz, Gozdem
    TALANTA, 2020, 218
  • [6] Cholesterol Determination Automated Determination by using LC/GC-FID
    Kresse, Michael
    Biederbick, Thomas
    Zoost, Christiane
    DEUTSCHE LEBENSMITTEL-RUNDSCHAU, 2019, 115 (02) : 50 - 56
  • [7] Determination of elaidic and vaccenic acids in foods using GC x GC-FID and GC x GC-TOFMS
    Ha, Jaeho
    Seo, Dongwon
    Shin, Dongbin
    TALANTA, 2011, 85 (01) : 252 - 258
  • [8] A GC-FID method for analysis of Lysinoalanine
    Montilla, Antonia
    Gomez-Ruiz, Jose Angel
    Olano, Agustin
    del Castillo, Maria Dolores
    MOLECULAR NUTRITION & FOOD RESEARCH, 2007, 51 (04) : 415 - 422
  • [9] Determination of carbamazepine in pharmaceutical dosage form using GC-FID
    Kadioglu, Yucel
    Demirkaya, Fatma
    CHROMATOGRAPHIA, 2007, 66 (Suppl 1) : S169 - S172
  • [10] Determination of Vitamin E in Cereal Products and Biscuits by GC-FID
    Pasias, Ioannis N.
    Kiriakou, Ioannis K.
    Papakonstantinou, Lila
    Proestos, Charalampos
    FOODS, 2018, 7 (01):