Effect of mechanical dry particle coating on the improvement of powder flowability for lactose monohydrate: A model cohesive pharmaceutical powder

被引:52
|
作者
Zhou, Qi [1 ]
Qu, Li [1 ]
Larson, Ian [1 ]
Stewart, Peter J. [1 ]
Morton, David A. V. [1 ]
机构
[1] Monash Univ, Monash Inst Pharmaceut Sci, Parkville, Vic 3052, Australia
关键词
Mechanical dry coating; Mechanofusion; Lactose; Cohesive powder; Powder flowability; FLOW PROPERTIES; FINE; SIZE;
D O I
10.1016/j.powtec.2010.11.028
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The aim of this study was to evaluate the effect of an intensive dry coating process on the improvement in flow behaviours for fine cohesive lactose powders as a function of size distribution and coating process parameters. Various commercial fine lactose powders with particle size range from approximately 4 to 120 mu m were dry coated with magnesium stearate using a recently optimised mechanofusion approach. The bulk densities for all cohesive powders increased and flow behaviours were improved substantially except for the already free-flowing powder of R010 (with VMD approximately 120 mu m). Of particular note, the originally non-flowing cohesive powder P450 with VMD approximately 20 mu m achieved free-flowing characteristics and was as flowable as R010 after mechanofusion. The improvement in powder flow behaviours was shown to be dependent on coating parameters such as coating speed and coating time duration. At an appropriate coating speed, optimal coating can be achieved after processing for 5 min for P450. This study demonstrated that an optimised mechanofusion process is an efficient and effective approach for substantially improving flow of fine cohesive powders to achieve equivalent flow behaviours of much larger sized powders. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:414 / 421
页数:8
相关论文
共 50 条
  • [41] The effect of the particle shape and structure on the flowability of electrolytic copper powder. IV. The internal structure of the powder particles
    Popov, KI
    Krstic, SB
    Pavlovic, MG
    Pavlovic, LJ
    Maksimovic, VM
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2004, 69 (10) : 817 - 825
  • [42] The effect of the particle shape and structure on the flowability of electrolytic copper powder. IV. the internal structure of the powder particles
    Popov, Konstantin I.
    Krstić, Snezana B.
    Pavlović, Miomir G.
    Pavlović, Ljubica J.
    Maksimović, Vesna M.
    J. Serb. Chem. Soc., 10 (817-825):
  • [43] Functionalised particles using dry powder coating in pharmaceutical drug delivery: promises and challenges
    Dahmash, Eman Z.
    Mohammed, Afzal R.
    EXPERT OPINION ON DRUG DELIVERY, 2015, 12 (12) : 1867 - 1879
  • [44] Effect of compression pressure on inhalation grade lactose as carrier for dry powder inhalations
    Raut, Neha Sureshrao
    Jamaiwar, Swapnil
    Umekar, Milind Janrao
    Kotagale, Nandkishor Ramdas
    INTERNATIONAL JOURNAL OF PHARMACEUTICAL INVESTIGATION, 2016, 6 (01) : 39 - 46
  • [45] The Effect of Engineered Mannitol-Lactose Mixture on Dry Powder Inhaler Performance
    Waseem Kaialy
    Hassan Larhrib
    Gary P. Martin
    Ali Nokhodchi
    Pharmaceutical Research, 2012, 29 : 2139 - 2156
  • [46] The Effect of Engineered Mannitol-Lactose Mixture on Dry Powder Inhaler Performance
    Kaialy, Waseem
    Larhrib, Hassan
    Martin, Gary P.
    Nokhodchi, Ali
    PHARMACEUTICAL RESEARCH, 2012, 29 (08) : 2139 - 2156
  • [47] Effect of carrier particle shape on dry powder inhaler performance
    Kaialy, Waseem
    Alhalaweh, Amjad
    Velaga, Sitaram P.
    Nokhodchi, Ali
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2011, 421 (01) : 12 - 23
  • [48] Improved properties of fine active pharmaceutical ingredient powder blends and tablets at high drug loading via dry particle coating
    Kunnath, Kuriakose
    Huang, Zhonghui
    Chen, Liang
    Zheng, Kai
    Dave, Rajesh
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2018, 543 (1-2) : 288 - 299
  • [49] Method Development for Analysis of Lactose Aerodynamic Particle Size Distributions in Dry Powder Inhaler Products
    Heath, Victoria
    Lu, Wenan
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2010, 62 (10) : 1210 - 1211
  • [50] Influence of lactose carrier particle size on the aerosol performance of budesonide from a dry powder inhaler
    Kaialy, Waseem
    Alhalaweh, Amjad
    Velaga, Sitaram P.
    Nokhodchi, Ali
    POWDER TECHNOLOGY, 2012, 227 : 74 - 85