Comparative evaluation of harmonic extraction techniques for three-phase three-wire active power filter

被引:0
|
作者
Chudamani, R. [1 ]
Vasudevan, Krishna [1 ]
Ramalingam, C. S. [1 ]
机构
[1] Indian Inst Technol, Madras 600036, Tamil Nadu, India
关键词
nonlinear least squares; harmonic elimination; compensation lag;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper the performance of four harmonic extraction algorithms for active power filters are evaluated based on their steady state and dynamic performance. The techniques which are considered for comparative study are (i) filtering approach using the conventional low pass filter, (ii) instantaneous real and imaginary power (pq) theory, (iii) instantaneous active and reactive currents method (dq), and (iv) nonlinear least squares (NLS) estimation method. Comparison is based on simulation studies carried out in SABER It is shown through simulation results that the dynamic behaviour of the harmonic extraction approach has an effect on the active power filter ratings. The simulation study reveals the superiority of the nonlinear least squares approach. This method provides good dynamic response and also extracts the load current harmonics explicitly.
引用
收藏
页码:1827 / +
页数:3
相关论文
共 50 条
  • [41] Modelling and comparative evaluation of control techniques applied to a PWM three-phase four-wire shunt active power filter
    Kanaan, H. Y.
    Georges, S.
    Hayek, A.
    Al-Haddad, K.
    [J]. 2006 1ST IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOLS 1-3, 2006, : 300 - +
  • [42] Determination of Power Losses in a Three-phase Three-wire Shield.
    Szendzielorz, Aleksander
    Zaczek, Jerzy
    [J]. Archiwum Elektrotechniki, 1983, 32 (1-2): : 261 - 268
  • [43] LQR with integral action to enhance dynamic performance of three-phase three-wire shunt active filter
    Kedjar, Bachir
    Al-Haddad, Karnal
    [J]. 2007 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, 2007, : 1138 - 1144
  • [44] Shunt active power filter control for compensating current power quality problems in three-phase three-wire systems based on an adaptive notch filter
    Tabatabaei, Seyed Hossein
    Moslehi Bajestan, Mehran
    Jalilian, Alireza
    [J]. TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2016, 24 (04) : 2539 - 2555
  • [45] OTA & CCII-Based Control System of Shunt Active Power Filter Using in Three-Phase Three-wire System
    Vanichprapa, Sombat
    Prapanavarat, Cherdchai
    Chipipop, Boonruk
    [J]. INTERNATIONAL CONFERENCE ON POWER CONTROL AND OPTIMIZATION, 2008, 1052 : 30 - +
  • [46] A three-phase active power filter for harmonic and reactive power compensation
    Singh, B
    Chandra, A
    AlHaddad, K
    [J]. 1996 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING - CONFERENCE PROCEEDINGS, VOLS I AND II: THEME - GLIMPSE INTO THE 21ST CENTURY, 1996, : 838 - 841
  • [47] Adaptive Control of DC Voltage in Three-Phase Three-Wire Shunt Active Power Filters Systems
    Popescu, Mihaela
    Bitoleanu, Alexandru
    Suru, Constantin Vlad
    Linca, Mihaita
    Subtirelu, Gheorghe Eugen
    [J]. ENERGIES, 2020, 13 (12)
  • [48] Third Harmonic Injection on Sliding Mode Control for a Three-Phase, Three-Wire Inverter
    Alarcon-Gallo, Eduardo
    [J]. 39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 1910 - 1915
  • [49] Reduction of Dc-Link Capacitance for Three-Phase Three-Wire Shunt Active Power Filters
    Jin, Chi
    Tang, Yi
    Wang, Peng
    Liu, Xiong
    Zhu, Dexuan
    Blaabjerg, Frede
    [J]. 39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 1203 - 1208
  • [50] Fault tolerant control of a three-phase three-wire shunt active filter system based on reliability analysis
    Poure, P.
    Weber, P.
    Theilliol, D.
    Saadate, S.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (02) : 325 - 334