A phantom-based analysis for tracking intra-fraction pancreatic tumor motion by ultrasound imaging during radiation therapy

被引:1
|
作者
Ji, Tianlong [1 ,2 ]
Feng, Ziwei [2 ,3 ]
Sun, Edward [2 ]
Ng, Sook Kien [2 ]
Su, Lin [2 ]
Zhang, Yin [2 ]
Han, Dong [2 ]
Han-Oh, Sarah [2 ]
Iordachita, Iulian [4 ]
Lee, Junghoon [2 ]
Kazanzides, Peter [5 ]
Bell, Muyinatu A. Lediju [3 ]
Wong, John [2 ]
Ding, Kai [2 ]
机构
[1] First Hosp China Med Univ, Dept Radiat Oncol, Shenyang, Peoples R China
[2] Johns Hopkins Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD USA
[4] Johns Hopkins Univ, Dept Mech Engn, Baltimore, MD USA
[5] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD USA
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
基金
美国国家卫生研究院;
关键词
ultrasound image tracking; radiation therapy; respiratory motion; ultrasound image; abdominal; 4-DIMENSIONAL COMPUTED-TOMOGRAPHY; GUIDED RADIOTHERAPY; SPECKLE TRACKING; GUIDANCE; MANAGEMENT; CANCER; ADENOCARCINOMA; FEASIBILITY; HYDROGEL; LIVER;
D O I
10.3389/fonc.2022.996537
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PurposeIn this study, we aim to further evaluate the accuracy of ultrasound tracking for intra-fraction pancreatic tumor motion during radiotherapy by a phantom-based study. MethodsTwelve patients with pancreatic cancer who were treated with stereotactic body radiation therapy were enrolled in this study. The displacement points of the respiratory cycle were acquired from 4DCT and transferred to a motion platform to mimic realistic breathing movements in our phantom study. An ultrasound abdominal phantom was placed and fixed in the motion platform. The ground truth of phantom movement was recorded by tracking an optical tracker attached to this phantom. One tumor inside the phantom was the tracking target. In the evaluation of the results, the monitoring results from the ultrasound system were compared with the phantom motion results from the infrared camera. Differences between infrared monitoring motion and ultrasound tracking motion were analyzed by calculating the root-mean-square error. ResultsThe 82.2% ultrasound tracking motion was within a 0.5 mm difference value between ultrasound tracking displacement and infrared monitoring motion. 0.7% ultrasound tracking failed to track accurately (a difference value > 2.5 mm). These differences between ultrasound tracking motion and infrared monitored motion do not correlate with respiratory displacements, respiratory velocity, or respiratory acceleration by linear regression analysis. ConclusionsThe highly accurate monitoring results of this phantom study prove that the ultrasound tracking system may be a potential method for real-time monitoring targets, allowing more accurate delivery of radiation doses.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Analysis of Intra-Fraction Chest Wall Motion during Breath Hold Treatment for Left Sided Breast Cancer
    Nelson, C.
    Gifford, K.
    Kirsner, S.
    Shah, S.
    Bloom, E.
    Mason, B.
    Arzu, I.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [42] Intra-fraction patient displacement during image-guided stereotactic body radiation therapy (IGSBRT) for lung treatment
    Olivier, K.
    Chung, H.
    Jin, H.
    Yang, H.
    Kim, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S489 - S489
  • [43] Analysis of response time delays in an adaptive feedback system: Considerations for a real-time intra-fraction motion tracking couch
    D'Souza, W
    Naqvi, S
    Yu, C
    Suntha, M
    Regine, W
    MEDICAL PHYSICS, 2005, 32 (06) : 1920 - 1921
  • [44] The use of a 3D surface based imaging system to assess intra-fraction motion for breast cancer patients
    Wright, S.
    Lau, Y. G. J.
    Naisbit, M.
    Needham, A.
    Artschan, R. E. R.
    Sykes, J. R.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S231 - S231
  • [45] Intra-Fraction Motion and Dosimetric Effects of Liver Stereotactic Body Radiation Therapy During Free-Breathing, Exhale and Inhale Active Breath-Hold
    Nano, T. F.
    Feng, M.
    Capaldi, D. Pi
    Sharma, M.
    Hirata, E.
    Lim, S.
    Anwar, M.
    Hira, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E429 - E429
  • [46] Dosimetric Impact of Intra-Fraction Lung Tumor Rotation in Real-Time Tumor-Tracking Radiotherapy Using a Developed 6DoF Robotic Phantom System
    Shiinoki, T.
    Fujii, F.
    Yuasa, Y.
    Nonomura, T.
    Fujimoto, K.
    Sera, T.
    Tanaka, H.
    MEDICAL PHYSICS, 2020, 47 (06) : E757 - E757
  • [47] Intra-Fraction Motion Analysis for Frameless Linac-Based Stereotactic Radiosurgery with Three-Dimension (3D) Optical Surface Imaging for Intra-Fractional Motion Management
    Chen, S.
    Agyepong, B.
    Poirier, Y.
    Lamichhane, N.
    Becker, S. J.
    Zhang, B.
    Gopal, A.
    Yi, B. Y.
    Mohindra, P.
    Nichols, E. M.
    Molitoris, J. K.
    Mishra, M. V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E759 - E759
  • [48] Feasibility of Using Ultrasound to Monitor Intrafraction Motion During Radiation Therapy for Pancreatic Cancer
    Noid, G.
    Paulson, E. S.
    Prah, D.
    Li, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S837 - S837
  • [49] Improving the intra-fraction update efficiency of a correlation model used for internal motion estimation during real-time tumor tracking for SBRT patients: Fast update or no update?
    Poels, Kenneth
    Depuydt, Tom
    Verellen, Dirk
    Gevaert, Thierry
    Dhont, Jennifer
    Duchateau, Michael
    Burghelea, Manuela
    Boussaer, Marlies
    Steenbeke, Femke
    Collen, Christine
    Engels, Benedikt
    Storme, Guy
    De Ridder, Mark
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (03) : 352 - 359
  • [50] Evaluation of inter- and intra-fraction 6D motion for stereotactic body radiation therapy of spinal metastases: influence of treatment time
    Ahmed Hadj Henni
    David Gensanne
    Maximilien Roge
    Chantal Hanzen
    Guillaume Bulot
    Elyse Colard
    Sebastien Thureau
    Radiation Oncology, 16