Combined spin- and gradient-echo perfusion-weighted imaging

被引:82
|
作者
Schmiedeskamp, Heiko [1 ]
Straka, Matus [1 ]
Newbould, Rexford D. [2 ]
Zaharchuk, Greg [1 ]
Andre, Jalal B. [1 ]
Olivot, Jean-Marc [3 ]
Moseley, Michael E. [1 ]
Albers, Gregory W. [3 ]
Bammer, Roland [1 ]
机构
[1] Stanford Univ, Lucas Ctr, Dept Radiol, Stanford, CA 94305 USA
[2] Hammersmith Hosp, GSK Clin Imaging Ctr, London, England
[3] Stanford Univ, Med Ctr, Dept Neurol & Neurol Sci, Stanford Stroke Ctr, Stanford, CA 94305 USA
关键词
spin-echo EPI; gradient-echo EPI; multiecho acquisition; dynamic susceptibility-weighted perfusion-weighted imaging; SAGE PWI; DYNAMIC-SUSCEPTIBILITY-CONTRAST; CEREBRAL BLOOD-VOLUME; ARTERIAL INPUT FUNCTION; HIGH-RESOLUTION MEASUREMENT; TRACER BOLUS PASSAGES; TRANSVERSE RELAXATION; PULSE DESIGN; ACUTE STROKE; ENHANCED MR; TUMOR GRADE;
D O I
10.1002/mrm.23195
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this study, a spin- and gradient-echo echo-planar imaging (SAGE EPI) MRI pulse sequence is presented that allows simultaneous measurements of gradient-echo and spin-echo dynamic susceptibility-contrast perfusion-weighted imaging data. Following signal excitation, five readout trains were acquired using spin- and gradient-echo echo-planar imaging, all of them with echo times of less than 100 ms. Contrast agent concentrations in brain tissue were determined based on absolute R?2* and R2 estimates rather than relative changes in the signals of individual echo trains, producing T1-independent dynamic susceptibility-contrast perfusion-weighted imaging data. Moreover, this acquisition technique enabled vessel size imaging through the simultaneous quantification of R?2* and R2, without an increase in acquisition time. In this work, the concepts of SAGE EPI pulse sequence and results in stroke and tumor imaging are presented. Overall, SAGE EPI combined the advantages of higher sensitivity to contrast agent passage of gradient-echo perfusion-weighted imaging with better microvascular selectivity of spin-echo perfusion-weighted imaging. Magn Reson Med, 2012. (C) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:30 / 40
页数:11
相关论文
共 50 条
  • [1] Simultaneous multi-slice spin- and gradient-echo dynamic susceptibility-contrast perfusion-weighted MRI of gliomas
    Han, Misung
    Yang, Baolian
    Fernandez, Brice
    Lafontaine, Marisa
    Alcaide-Leon, Paula
    Jakary, Angela
    Burns, Brian L.
    Morrison, Melanie A.
    Villanueva-Meyer, Javier E.
    Chang, Susan M.
    Banerjee, Suchandrima
    Lupo, Janine M.
    NMR IN BIOMEDICINE, 2021, 34 (01)
  • [2] Simultaneous perfusion and permeability measurements using combined spin- and gradient-echo MRI
    Schmiedeskamp, Heiko
    Andre, Jalal B.
    Straka, Matus
    Christen, Thomas
    Nagpal, Seema
    Recht, Lawrence
    Thomas, Reena P.
    Zaharchuk, Greg
    Bammer, Roland
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2013, 33 (05): : 732 - 743
  • [3] Compensation of slice profile mismatch in combined spin- and gradient-echo echo-planar imaging pulse sequences
    Schmiedeskamp, Heiko
    Straka, Matus
    Bammer, Roland
    MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (02) : 378 - 388
  • [4] Evaluation of a multiple spin- and gradient-echo (SAGE) EPI acquisition with SENSE acceleration: Applications for perfusion imaging in and outside the brain
    Skinner, Jack T.
    Robison, Ryan K.
    Elder, Christopher P.
    Newton, Allen T.
    Damon, Bruce M.
    Quarles, C. Chad
    MAGNETIC RESONANCE IMAGING, 2014, 32 (10) : 1171 - 1180
  • [5] Assessment of a combined spin- and gradient-echo (SAGE) DSC-MRI method for preclinical neuroimaging
    Stokes, Ashley M.
    Skinner, Jack T.
    Quarles, C. Chad
    MAGNETIC RESONANCE IMAGING, 2014, 32 (10) : 1181 - 1190
  • [6] SUSCEPTIBILITY ARTIFACTS IN SPIN-ECHO AND GRADIENT-ECHO IMAGING
    POSSE, S
    AUE, WP
    JOURNAL OF MAGNETIC RESONANCE, 1990, 88 (03): : 473 - 492
  • [7] Inflow effect correction in fast gradient-echo perfusion imaging
    Ivancevic, MK
    Zimine, I
    Montet, X
    Hyacinthe, JN
    Lazeyras, F
    Foxall, D
    Vallée, JP
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (05) : 885 - 891
  • [8] Characterization of Focal Brain Lesions by Gradient-Echo Arterial Spin-Tagging Perfusion Imaging
    Chai, Jyh-Wen
    Yang, Ming-Shiang
    Chen, Clayton Chi-Chang
    Chiang, Chih-Ming
    Chu, Woei-Chyn
    NEURORADIOLOGY JOURNAL, 2007, 20 (02): : 149 - 158
  • [9] Tumefactive demyelinating lesions by combined perfusion-weighted and diffusion weighted imaging
    Tsui, EYK
    Leung, WH
    Chan, JH
    Cheung, YK
    Ng, SH
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (05) : 343 - 346
  • [10] Perfusion-sensitive MR imaging of gliomas: Comparison between gradient-echo and spin-echo echo-planar imaging techniques
    Sugahara, T
    Korogi, Y
    Kochi, M
    Ushio, Y
    Takahashi, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (07) : 1306 - 1315