Correlation between In Vitro Neutralization Assay and Serological Tests for Protective Antibodies Detection

被引:11
|
作者
Bonifacio, Maria Addolorata [1 ]
Laterza, Riccardo [1 ]
Vinella, Angela [1 ]
Schirinzi, Annalisa [2 ]
Defilippis, Mariangela [3 ]
Di Serio, Francesca [2 ]
Ostuni, Angelo [3 ]
Fasanella, Antonio [4 ]
Mariggio, Maria Addolorata [1 ]
机构
[1] Univ Bari Aldo Moro, Dept Biomed Sci & Human Oncol, Med Sch, I-70124 Bari, Italy
[2] Univ Bari Aldo Moro, Clin Pathol Unit, I-70124 Bari, Italy
[3] Univ Bari Aldo Moro, Azienda Osped Univ Consorziale Policlin Bari, Immunohematol & Transfus Med Serv, I-70124 Bari, Italy
[4] Ist Ist Zooprofilatt Sperimentale Puglia & Basili, I-71121 Foggia, Italy
关键词
SARS-CoV-2; antibodies; diagnostics; serological test; surrogate virus neutralization test (sVNT); plaque reduction neutralization test (PRNT); ELISA; epidemiology; humoral immunity; ROC curve;
D O I
10.3390/ijms23179566
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Serological assays are useful in investigating the development of humoral immunity against SARS-CoV-2 in the context of epidemiological studies focusing on the spread of protective immunity. The plaque reduction neutralization test (PRNT) is the gold standard method to assess the titer of protective antibodies in serum samples. However, to provide a result, the PRNT requires several days, skilled operators, and biosafety level 3 laboratories. Therefore, alternative methods are being assessed to establish a relationship between their outcomes and PRNT results. In this work, four different immunoassays (Roche Elecsys(R) Anti SARS-CoV-2 S, Snibe MAGLUMI(R) SARS-CoV-2 S-RBD IgG, Snibe MAGLUMI(R) 2019-nCoV IgG, and EUROIMMUN(R) SARS-CoV-2 NeutraLISA assays, respectively) have been performed on individuals healed after SARS-CoV-2 infection. The correlation between each assay and the reference method has been explored through linear regression modeling, as well as through the calculation of Pearson's and Spearman's coefficients. Furthermore, the ability of serological tests to discriminate samples with high titers of neutralizing antibodies (>160) has been assessed by ROC curve analyses, Cohen's Kappa coefficient, and positive predictive agreement. The EUROIMMUN(R) NeutraLISA assay displayed the best correlation with PRNT results (Pearson and Spearman coefficients equal to 0.660 and 0.784, respectively), as well as the ROC curve with the highest accuracy, sensitivity, and specificity (0.857, 0.889, and 0.829, respectively).
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Comparison of five commercial serological tests for the detection of anti-Chlamydia trachomatis antibodies
    Baud, D.
    Regan, L.
    Greub, G.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2010, 29 (06) : 669 - 675
  • [32] Sensitivity of serological tests for the detection of anti-CagA antibodies in patients with gastric carcinoma
    Rocha, GA
    Oliveira, AMR
    Queiroz, DMM
    Mendes, EN
    Oliveira, CA
    Magalhaes, PP
    GUT, 1999, 45 : A126 - A126
  • [33] Comparison of different serological tests for detection of bovine herpes virus 1 antibodies in sheep
    Singh, RP
    Bhat, MN
    Sastry, KNV
    INDIAN JOURNAL OF ANIMAL SCIENCES, 2000, 70 (10): : 1047 - 1048
  • [34] COMPARISON AND EVALUATION OF 3 SEROLOGICAL TESTS FOR DETECTION OF ANTIBODIES TO INFECTIOUS BOVINE-RHINOTRACHEITIS
    ZHOU, CF
    OLIVER, RE
    MOTHA, MXJ
    FORBES, SD
    NEW ZEALAND VETERINARY JOURNAL, 1988, 36 (04) : 204 - 205
  • [35] Comparison of five commercial serological tests for the detection of anti-Chlamydia trachomatis antibodies
    D. Baud
    L. Regan
    G. Greub
    European Journal of Clinical Microbiology & Infectious Diseases, 2010, 29 : 669 - 675
  • [36] Detection of neutralization antibodies to primate polyomaviruses using a single-cycle reporter virus assay
    Sheng, Li
    Klutch, Michael
    Lewis, Andrew M.
    Peden, Keith
    JOURNAL OF NEUROVIROLOGY, 2005, 14 : 71 - 71
  • [37] Development of a rapid neutralization assay for the detection of neutralizing antibodies against coxsackievirus B1
    Wu, Yuanyuan
    Yin, Zhichao
    Zhu, Rui
    Xu, Longfa
    Huang, Qiongzi
    Zhang, Dongqing
    Yang, Hongwei
    Zhou, Zhenhong
    Zhang, Jun
    Cheng, Tong
    Xia, Ningshao
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2022, 103 (02)
  • [38] Evaluation of the focus reduction neutralization and ELISA tests compared to the plaque reduction neutralization test for the detection of antibodies against measles virus
    Yaghoobizad, Somayeh
    Norouzbabaei, Zahra
    Jandaghi, Nazanin Zahra Shafiei
    Foroushani, Abbas Rahimi
    Sadeghi, Kaveh
    Izadi, Shahrokh
    Fatemi-Nasab, Ghazal Sadat
    Heidari, Elaheh
    Salimi, Vahid
    Mokhtari-Azad, Talat
    BIOLOGICALS, 2024, 88
  • [39] CORRELATION BETWEEN SERUM NEUTRALIZATION TEST AND INDIRECT IMMUNOFLUORESCENT TEST FOR DETECTION OF SPECIFIC ANTIBODIES TO INFECTIOUS BOVINE-RHINOTRACHEITIS VIRUS
    ASSAF, R
    MARSOLAIS, G
    MAROIS, P
    PAYMENT, P
    CANADIAN JOURNAL OF COMPARATIVE MEDICINE-REVUE CANADIENNE DE MEDECINE COMPAREE, 1975, 39 (02): : 224 - 226
  • [40] A COMPARISON OF NEUTRALIZATION TESTS FOR THE DETECTION OF ANTIBODIES TO HERPESVIRUS-SIMIAE (MONKEY B-VIRUS)
    BOULTER, EA
    KALTER, SS
    HEBERLING, RL
    GUAJARDO, JE
    LESTER, TL
    LABORATORY ANIMAL SCIENCE, 1982, 32 (02): : 150 - 152