Laboratory investigation of GCL hydration from clayey sand subsoil

被引:70
|
作者
Anderson, R. [1 ]
Rayhani, M. T. [1 ]
Rowe, R. K. [2 ]
机构
[1] Carleton Univ, Dept Civil & Environm Engn, Ottawa, ON K1S 5B6, Canada
[2] Queens Univ, GeoEngn Ctr Queens RMC, Kingston, ON K7L 3N6, Canada
关键词
Geosynthetic clay liners (GCL); Hydration; Thermal cycles;
D O I
10.1016/j.geotexmem.2011.10.005
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
The hydration of Geosynthetic Clay Liners (GCLs) from underlying clayey sand subsoil (SC) is studied. The effect of product type and initial subsoil moisture content on GCL hydration is examined for both isothermal conditions at room temperature and for daily thermal cycles over several months. GCL hydration is shown to be highly dependent on the initial moisture content of the subsoil. For a subsoil initial moisture content of 5%, GCLs were only able to reach 12-18% of maximum hydration in over 22 weeks. For a subsoil initial moisture content close to field capacity (20%), GCLs were able to reach 90-91% of maximum hydration over 22 weeks. The method of GCL manufacture is shown to greatly affect the maximum hydration reached as well as the swelling of the respective GCLs. Daily thermal cycles greatly reduced hydration and kept the gravimetric moisture content of the GCLs below 30% of what was reached under isothermal conditions at room temperature. Compared to sand (SP) and silty sand (SM) subsoils, clayey sand (SC) slowed the rate of hydration of the GCLs and reduced the final equilibrium moisture content attained. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [31] Correction to: Experimental investigation of nano‑ZnO effect on mechanical properties of cemented clayey sand
    Abbas Babaei
    Mahmoud Ghazavi
    Navid Ganjian
    Bulletin of Engineering Geology and the Environment, 2022, 81
  • [32] Electrokinetics to Modify Strength Characteristics of Soft Clayey Soils: A Laboratory Based Investigation
    Jayasekera, S.
    ELECTROCHIMICA ACTA, 2015, 181 : 39 - 47
  • [33] Laboratory investigation of flow rate through composite liners consisting of a geomembrane, a GCL and a soil liner
    Barroso, Madalena
    Touze-Foltz, Nathalie
    von Maubeuge, Kent
    Pierson, Patrick
    GEOTEXTILES AND GEOMEMBRANES, 2006, 24 (03) : 139 - 155
  • [34] A Laboratory Investigation on a Mechanical Behavior of Sandy and Clayey Soils with Kraft Paper Fiber
    Paulo Jose Rocha de Albuquerque
    Daphne Rosana León-Mogrovejo
    Transportation Infrastructure Geotechnology, 2021, 8 : 12 - 36
  • [35] A Laboratory Investigation on a Mechanical Behavior of Sandy and Clayey Soils with Kraft Paper Fiber
    Rocha de Albuquerque, Paulo Jose
    Rosana Leon-Mogrovejo, Daphne
    TRANSPORTATION INFRASTRUCTURE GEOTECHNOLOGY, 2021, 8 (01) : 12 - 36
  • [36] Laboratory investigation on liquefaction of sands and cemented sand mixes
    Darisi, Devi Priyanka
    Munaga, Teja
    Gonavaram, Kalyan Kumar
    GEOMECHANICS AND GEOENGINEERING-AN INTERNATIONAL JOURNAL, 2024, 19 (02): : 97 - 109
  • [37] LABORATORY INVESTIGATION OF FROZEN SAND SOIL RADIATION CHARACTERISTICS
    ILYIN, VA
    SLOBODCHIKOVA, SV
    RADIOTEKHNIKA I ELEKTRONIKA, 1994, 39 (05): : 800 - 806
  • [38] A laboratory investigation of temperatrue-induced sand consolidation
    Ross, C. M.
    Rangel-German, E. R.
    Castanier, L. M.
    Hara, P. S.
    Kovscek, A. R.
    SPE JOURNAL, 2006, 11 (02): : 206 - 215
  • [39] A laboratory investigation of temperature-induced sand consolidation
    Dept. of Petroleum Engineering, Stanford University, Mexico, United States
    不详
    不详
    不详
    不详
    不详
    SPE J, 2006, 2 (206-215):
  • [40] A laboratory investigation into the effectiveness of a geocomposite as sand blanket replacement
    Ghataora, G
    Burrow, M
    Matson, N
    Geotechnics in Pavement and Railway Design and Construction, 2004, : 201 - 208