Carotid stenosis measurement on colour Doppler ultrasound: Agreement of ECST, NASCET and CCA methods applied to ultrasound with intra-arterial angiographic stenosis measurement

被引:31
|
作者
Wardlaw, JA [1 ]
Lewis, S [1 ]
机构
[1] Western Gen Hosp, Div Clin Neurosci, Edinburgh EH4 2XU, Midlothian, Scotland
关键词
carotid stenosis; stroke; Doppler ultrasound; angiography; cerebral infarction;
D O I
10.1016/j.ejrad.2005.04.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Carotid stenosis is usually determined on Doppler ultrasound from velocity readings. We wondered if angiography-style stenosis measurements applied to ultrasound images improved accuracy over velocity readings alone, and if so, which measure correlated best with angiography. Materials and methods: We studied prospectively patients undergoing colour Doppler ultrasound (CDU) for TIA or minor stroke. Those with 50%+ symptomatic internal carotid artery (ICA) stenosis had intra-arterial angiography (IAA). We measured peak systolic ICA velocity, and from the ultrasound image, the minimal residual lumen, the original lumen (ECST), ICA diameter distal (NASCET) and CCA diameter proximal (CCA method) to the stenosis. The IAAs were measured by ECST, NASCET and CCA methods also, blind to CDU. Results: Amongst 164 patients (328 arteries), on CDU the ECST, NASCET and CCA stenosis measures were similarly related to each other (ECST = 0.54 NASCET + 46) as on IAA (ECST = 0.6 NASCET + 40). Agreement between CDU- and IAA-measured stenosis was similar for ECST (r = 0.51), and CCA (r = 0.48) methods, and slightly worse for NASCET (r = 0.41). Adding IAA-style stenosis to the peak systolic ICA velocity did not improve agreement with IAA over peak systolic velocity alone. Conclusion: Angiography-style stenosis measures have similar inter-relationships when applied to CDU, but do not improve accuracy of ultrasound over peak systolic ICA velocity alone. (C) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
下载
收藏
页码:205 / 211
页数:7
相关论文
共 40 条
  • [31] IDENTIFICATION OF PATIENTS WITH AORTIC-STENOSIS IN WHOM DOPPLER ULTRASOUND MAY REPLACE THE INVASIVE MEASUREMENT OF PRESSURE-GRADIENTS
    HOFFMANN, A
    BURCKHARDT, D
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 42 - 43
  • [32] Assessment of peripheral skeletal muscle microperfusion in a porcine model of peripheral arterial stenosis by steady-state contrast-enhanced ultrasound and Doppler flow measurement
    Naehle, Claas P.
    Steinberg, Verena A.
    Schild, Hans
    Mommertz, Gottfried
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (05) : 1312 - 1320
  • [33] COMPARISON OF 2 METHODS OF MEASURING ARTERIAL DEFICIT (DOPPLER ULTRASOUND VELOCIMETRY WITH IMPULSES AND ELECTROMAGNETIC DEFICIT MEASUREMENT) IN THE DOG
    CHAUVEAU, M
    DESSANGES, JF
    SAVIN, E
    BAILLIART, O
    MARTINEAUD, JP
    JOURNAL DE PHYSIOLOGIE, 1981, 77 (09): : A63 - A63
  • [34] MEASUREMENT OF THE END-DIASTOLIC PRESSURE-GRADIENT AND MITRAL-VALVE AREA IN MITRAL-STENOSIS BY DOPPLER ULTRASOUND
    ROBSON, DJ
    FLAXMAN, JC
    EUROPEAN HEART JOURNAL, 1984, 5 (08) : 660 - 667
  • [35] Sensitivity and specificity of color duplex ultrasound measurement in the estimation of internal carotid artery stenosis:: A systematic review and meta-analysis
    Jahromi, AS
    Cinà, CS
    Liu, Y
    Clase, CM
    JOURNAL OF VASCULAR SURGERY, 2005, 41 (06) : 962 - 972
  • [36] New Technologies in the Assessment of Carotid Stenosis: Beyond the Color-Doppler Ultrasound-High Frame Rate Vector-Flow and 3D Arterial Analysis Ultrasound
    David, Emanuele
    Martinelli, Ombretta
    Pacini, Patrizia
    Di Serafino, Marco
    Huang, Pintong
    Dolcetti, Vincenzo
    Del Gaudio, Giovanni
    Barr, Richard G.
    Renda, Maurizio
    Lucarelli, Giuseppe T.
    Di Marzo, Luca
    Clevert, Dirk A.
    Solito, Carmen
    Di Bella, Chiara
    Cantisani, Vito
    DIAGNOSTICS, 2023, 13 (08)
  • [37] MultiNet 2.0: A lightweight attention-based deep learning network for stenosis measurement in carotid ultrasound scans and cardiovascular risk assessment
    Biswas, Mainak
    Saba, Luca
    Kalra, Mannudeep
    Singh, Rajesh
    Fernandes, J. Fernandes e
    Viswanathan, Vijay
    Laird, John R.
    Mantella, Laura E.
    Johri, Amer M.
    Fouda, Mostafa M.
    Suri, Jasjit S.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2024, 117
  • [38] Comparative study of normal dose contrast-enhanced MR angiography, color duplex ultrasound and intra-arterial DSA in the diagnosis of stenosis of aorta and iliac arteries
    Korst, MB
    Van der Vliet, JA
    Heijstraten, FM
    Klemm, PL
    Van Langen, H
    Barentsz, JO
    RADIOLOGY, 1999, 213P : 354 - 355
  • [39] ACCURACY OF ULTRASOUND DOPPLER VELOCITY-MEASUREMENT FOR PREDICTING GRADIENTS ACROSS STENOTIC VALVES - VALIDATION USING LASER DOPPLER IN AN INVITRO PULSATILE FLOW MODEL OF PULMONIC STENOSIS
    SAHN, DJ
    VALDESCRUZ, LM
    YOGANATHAN, AJ
    TOMIZUKA, F
    MAIN, J
    SWENSSON, RE
    PEDIATRIC CARDIOLOGY, 1984, 5 (03) : 239 - 239
  • [40] PRECISION OF MITRAL-VALVE AREA MEASUREMENT BY CARDIAC-CATHETERIZATION AND DOPPLER ULTRASOUND IN PATIENTS WITH MITRAL-STENOSIS - A BASIS FOR ASSESSMENT OF THE RESULTS OF CATHETER BALLOON COMMISSUROTOMY
    KAWANISHI, DT
    REID, CL
    STELLAR, W
    RAHIMTOOLA, SH
    CLINICAL RESEARCH, 1991, 39 (01): : A120 - A120