Measured microdosimetric spectra and therapeutic potential of boron neutron capture enhancement of 252Cf brachytherapy

被引:1
|
作者
Burmeister, J
Kota, C
Maughan, RL
机构
[1] Wayne State Univ, Harper Hosp, Gershenson Radiat Oncol Ctr, Karmanos Canc Inst, Detroit, MI 48201 USA
[2] Wayne State Univ, Detroit, MI 48201 USA
[3] Univ Penn, Dept Radiat Oncol, Philadelphia, PA 19104 USA
关键词
D O I
10.1667/RR3409.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Californium-252 is a neutron-emitting radioisotope used as a brachytherapy source for radioresistant tumors. Presented here are microdosimetric spectra measured as a function of simulated site diameter and distance from applicator tube Cf-252 sources. These spectra were measured using miniature tissue-equivalent proportional counters (TEPCs). An investigation of the clinical potential of boron neutron capture (BNC) enhancement of Cf-252 brachytherapy is also provided. The absorbed dose from the BNC reaction was measured using a boron-loaded miniature TEPC. Measured neutron, photon and BNC absorbed dose components are provided as a function of distance from the source. In general, the absorbed dose results show good agreement with results from other measurement techniques. A concomitant boost to Cf-252 brachytherapy may be provided through the use of the BNC reaction. The potential magnitude of this BNC enhancement increases with increasing distance from the source and is capable of providing a therapeutic gain greater than 30% at a distance of 5 cm from the source, assuming currently achievable boron concentrations. (c) 2005 by Radiation Research Society.
引用
收藏
页码:312 / 318
页数:7
相关论文
共 50 条
  • [31] Absolute Ratio 252Cf to 235U Prompt Fission Neutron Spectra
    Kornilov, N.
    Hambsch, F-J.
    NUCLEAR SCIENCE AND ENGINEERING, 2011, 168 (01) : 73 - 74
  • [32] Validation of capture reactions cross sections in 252Cf(s.f.) neutron field
    Schulc, Martin
    Novak, Evzen
    Simon, Jan
    Krechlerova, Alena
    Kostal, Michal
    Capote, Roberto
    APPLIED RADIATION AND ISOTOPES, 2025, 215
  • [33] Measurements and calculations of thermal neutron fluence rate and neutron energy spectra resulting from moderation of 252Cf fast neutrons:: Applications for neutron capture therapy
    Rivard, MJ
    MEDICAL PHYSICS, 2000, 27 (08) : 1761 - 1769
  • [34] Study of neutron spectra near the surfaces of iron and water spheres with 252Cf sources at their centers
    Sevast'yanov, VD
    Jansky, B
    Novak, E
    Turzik, Z
    Koshelev, AS
    Maslov, GN
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2005, 48 (05) : 567 - 581
  • [35] Neutron and gamma spectra measurements and calculations in benchmark spherical iron assemblies with 252Cf neutron source in the centre
    Jansky, B
    Novák, E
    Turzík, Z
    Kyncl, J
    Cvachovec, F
    Trykov, LA
    Volkov, VS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 476 (1-2): : 358 - 364
  • [36] Study of Neutron Spectra Near the Surfaces of Iron and Water Spheres with 252Cf Sources at Their Centers
    V. D. Sevast'yanov
    B. Jansky
    E. Novak
    Z. Turzik
    A. S. Koshelev
    G. N. Maslov
    Instruments and Experimental Techniques, 2005, 48 : 567 - 581
  • [37] Measuring neutron leakage spectra using spherical benchmarks with 252Cf source in its centers
    Schulc, Martin
    Kostal, Michal
    Novak, Evzen
    Rypar, Vojtech
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 914 : 53 - 56
  • [38] A MICRODOSIMETRIC STUDY OF THE DOSE ENHANCEMENT IN A FAST-NEUTRON BEAM DUE TO BORON NEUTRON-CAPTURE
    MAUGHAN, RL
    KOTA, C
    YUDELEV, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (12): : 1957 - 1961
  • [39] Benchmark experiments of thermal neutron and capture gamma-ray distributions in concrete using 252Cf
    Asano, Y
    Sugita, T
    NUCLEAR SCIENCE AND ENGINEERING, 2005, 151 (02) : 251 - 259
  • [40] Clinical brachytherapy with neutron emitting 252Cf sources and adherence to AAPM TG-43 dosimetry protocol
    Rivard, MJ
    Wierzbicki, JG
    Van den Heuvel, F
    Martin, RC
    McMahon, RR
    MEDICAL PHYSICS, 1999, 26 (01) : 87 - 96