Inter-operator and inter-device agreement and reliability of the SEM Scanner

被引:31
|
作者
Clendenin, Marta [1 ]
Jaradeh, Kindah [1 ]
Shamirian, Anasheh [1 ]
Rhodes, Shannon L. [1 ]
机构
[1] Bruin Biometr LLC, Los Angeles, CA 90024 USA
关键词
Pressure ulcer; Reproducibility; Medical device; NURSING-HOME RESIDENTS; RISK-ASSESSMENT-SCALES; PRESSURE ULCER CLASSIFICATION; SPINAL-CORD-INJURY; SUBEPIDERMAL MOISTURE; BRADEN SCALE; ELECTRICAL-PROPERTIES; ACUTE-CARE; PREVENTION; ERYTHEMA;
D O I
10.1016/j.jtv.2015.01.003
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Objective: The SEM Scanner is a medical device designed for use by healthcare providers as part of pressure ulcer prevention programs. The objective of this study was to evaluate the inter-rater and inter-device agreement and reliability of the SEM Scanner. Methods: Thirty-one (31) volunteers free of pressure ulcers or broken skin at the sternum, sacrum, and heels were assessed with the SEM Scanner. Each of three operators utilized each of three devices to collect readings from four anatomical sites (sternum, sacrum, left and right heels) on each subject for a total of 108 readings per subject collected over approximately 30 min. For each combination of operator-device-anatomical site, three SEM readings were collected. Interoperator and inter-device agreement and reliability were estimated. Results: Over the course of this study, more than 3000 SEM Scanner readings were collected. Agreement between operators was good with mean differences ranging from -0.01 to 0.11. Inter-operator and inter-device reliability exceeded 0.80 at all anatomical sites assessed. Conclusion: The results of this study demonstrate the high reliability and good agreement of the SEM Scanner across different operators and different devices. Given the limitations of current methods to prevent and detect pressure ulcers, the SEM Scanner shows promise as an objective, reliable tool for assessing the presence or absence of pressure-induced tissue damage such as pressure ulcers. (C) 2015 Bruin Biometrics, LLC. Published by Elsevier Ltd.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [31] On inter-operator data transfers in query processing
    Deshmukh, Harshad
    Sundarmurthy, Bruhathi
    Patel, Jignesh M.
    2022 IEEE 38TH INTERNATIONAL CONFERENCE ON DATA ENGINEERING (ICDE 2022), 2022, : 820 - 832
  • [32] Inter-operator radio interface based synchronization
    Linlin, Feng
    Zhizhong, Zhang
    Haonan, Hu
    Fang, Cheng
    Journal of China Universities of Posts and Telecommunications, 2015, 22 (01): : 31 - 41
  • [33] Inter-device variation in dual oximetry for polysomnography
    Jamieson, Patrick
    Burns, Paul
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40
  • [34] Association Between the Quantity of Subcutaneous Fat and the Inter-Device Agreement of 2 Tissue Oximeters
    Cournoyer, Alexis
    Cossette, Sylvie
    Paquet, Jean
    Daoust, Raoul
    Marquis, Martin
    Notebaert, Eric
    Iseppon, Massimiliano
    Chauny, Jean-Marc
    Denault, Andre
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (11) : 2989 - 2994
  • [35] Inter-operator radio interface based synchronization
    Linlin, Feng (fenglin0815@163.com), 1600, Beijing University of Posts and Telecommunications (22):
  • [36] Inter-device reproducibility of transcutaneous bilirubin meters
    Alida J. Dam-Vervloet
    Marlijn D. van Erk
    Nina Doorn
    Stefan G. J. Lip
    Nienke A. Timmermans
    Leen Vanwinsen
    Foky-Anna de Boer
    Henrica L. M. van Straaten
    Nienke Bosschaart
    Pediatric Research, 2021, 89 : 770 - 775
  • [37] Regulating Freeriding in Inter-Operator Spectrum Sharing
    Rahman, Mostafizur
    Yuksel, Murat
    Quint, Thomas
    2018 IEEE INTERNATIONAL SYMPOSIUM ON DYNAMIC SPECTRUM ACCESS NETWORKS (DYSPAN), 2018,
  • [38] Inter-device reliability of wearable technology for quantifying jump height in collegiate athletes
    Nickerson, Brett S.
    Medrano, Noel F.
    Perez, Gabriel L.
    Narvaez, Samantha, V
    Carrillo, Joshua
    Duque, Misael
    BIOLOGY OF SPORT, 2020, 37 (04) : 383 - 387
  • [39] Inter-device reliability of the NPi-200 and NPi-300 pupillometers
    Stutzman, Sonja
    Iype, Phebe
    Marshall, Jade
    Speir, Kinley
    Schneider, Nathan
    Tran, Conny
    Laird, Shannon
    Aiyagari, Venkatesh
    Olson, DaiWai
    JOURNAL OF CLINICAL NEUROSCIENCE, 2022, 100 : 180 - 183
  • [40] Inter-device reproducibility of transcutaneous bilirubin meters
    Dam-Vervloet, Alida J.
    van Erk, Marlijn D.
    Doorn, Nina
    Lip, Stefan G. J.
    Timmermans, Nienke A.
    Vanwinsen, Leen
    de Boer, Foky-Anna
    van Straaten, Henrica L. M.
    Bosschaart, Nienke
    PEDIATRIC RESEARCH, 2021, 89 (04) : 770 - 775