Differentiation Between Benign and Metastatic Breast Lymph Nodes Using Apparent Diffusion Coefficients

被引:8
|
作者
Fardanesh, Reza [1 ]
Thakur, Sunitha B. [1 ,2 ]
Sevilimedu, Varadan [3 ]
Horvat, Joao V. [1 ]
Gullo, Roberto Lo [1 ]
Reiner, Jeffrey S. [1 ]
Eskreis-Winkler, Sarah [1 ]
Thakur, Nikita [1 ,4 ]
Pinker, Katja [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Radiol, 1275 York Ave, New York, NY 10021 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10021 USA
[3] Mem Sloan Kettering Canc Ctr, Dept Epidemiol & Biostat, 1275 York Ave, New York, NY 10021 USA
[4] Touro Coll Osteopath Med, Middletown, NY USA
来源
FRONTIERS IN ONCOLOGY | 2022年 / 12卷
基金
美国国家卫生研究院;
关键词
breast cancer; prognostic factors; lymph nodes; diffusion-weighted imaging; apparent diffusion coefficient; MRI; DIAGNOSTIC-ACCURACY; FROZEN-SECTION; WEIGHTED MRI; INTRAOPERATIVE EVALUATION; IMAGING IMPROVES; IMPRINT CYTOLOGY; CANCER; BIOPSY; MAMMOGRAPHY; PERFORMANCE;
D O I
10.3389/fonc.2022.795265
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The aim of this study was to determine the range of apparent diffusion coefficient (ADC) values for benign axillary lymph nodes in contrast to malignant axillary lymph nodes, and to define the optimal ADC thresholds for three different ADC parameters (minimum, maximum, and mean ADC) in differentiating between benign and malignant lymph nodes. This retrospective study included consecutive patients who underwent breast MRI from January 2017-December 2020. Two-year follow-up breast imaging or histopathology served as the reference standard for axillary lymph node status. Area under the receiver operating characteristic curve (AUC) values for minimum, maximum, and mean ADC (min ADC, max ADC, and mean ADC) for benign vs malignant axillary lymph nodes were determined using the Wilcoxon rank sum test, and optimal ADC thresholds were determined using Youden's Index. The final study sample consisted of 217 patients (100% female, median age of 52 years (range, 22-81), 110 with benign axillary lymph nodes and 107 with malignant axillary lymph nodes. For benign axillary lymph nodes, ADC values (x10(-3) mm(2)/s) ranged from 0.522-2.712 for mean ADC, 0.774-3.382 for max ADC, and 0.071-2.409 for min ADC; for malignant axillary lymph nodes, ADC values (x10(-3) mm(2)/s) ranged from 0.796-1.080 for mean ADC, 1.168-1.592 for max ADC, and 0.351-0.688 for min ADC for malignant axillary lymph nodes. While there was a statistically difference in all ADC parameters (p<0.001) between benign and malignant axillary lymph nodes, boxplots illustrate overlaps in ADC values, with the least overlap occurring with mean ADC, suggesting that this is the most useful ADC parameter for differentiating between benign and malignant axillary lymph nodes. The mean ADC threshold that resulted in the highest diagnostic accuracy for differentiating between benign and malignant lymph nodes was 1.004x10(-3) mm(2)/s, yielding an accuracy of 75%, sensitivity of 71%, specificity of 79%, positive predictive value of 77%, and negative predictive value of 74%. This mean ADC threshold is lower than the European Society of Breast Imaging (EUSOBI) mean ADC threshold of 1.300x10(-3) mm(2)/s, therefore suggesting that the EUSOBI threshold which was recently recommended for breast tumors should not be extrapolated to evaluate the axillary lymph nodes.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] DIFFERENTIATION BETWEEN BENIGN AND MALIGNANT HUMAN LYMPH-NODES BY MEANS OF IMMUNOLOGICAL MARKERS
    BRUBAKER, DB
    WHITESIDE, TL
    CANCER, 1979, 43 (04) : 1165 - 1176
  • [42] Comparison between malignant and benign abdominal lymph nodes on diffusion-weighted imaging
    Akduman, E. Isin
    Momtahen, Amir Javad
    Balci, N. Cem
    Mahajann, Namit
    Havlioglu, Necat
    Wolverson, Michael K.
    ACADEMIC RADIOLOGY, 2008, 15 (05) : 641 - 646
  • [43] Apparent diffusion coefficient cannot discriminate metastatic and non-metastatic lymph nodes in rectal cancer: a meta-analysis
    Surov, Alexey
    Meyer, Hans-Jonas
    Pech, Maciej
    Powerski, Maciej
    Omari, Jasan
    Wienke, Andreas
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2021, 36 (10) : 2189 - 2197
  • [44] Apparent diffusion coefficient cannot discriminate metastatic and non-metastatic lymph nodes in rectal cancer: a meta-analysis
    Alexey Surov
    Hans-Jonas Meyer
    Maciej Pech
    Maciej Powerski
    Jasan Omari
    Andreas Wienke
    International Journal of Colorectal Disease, 2021, 36 : 2189 - 2197
  • [45] Apparent diffusion coefficients for differentiation of cerebellar tumors in children
    Rumboldt, Z
    Camacho, DLA
    Lake, D
    Welsh, CT
    Castillo, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (06) : 1362 - 1369
  • [46] Endobronchial ultrasound elastography for the differentiation of benign and malignant lymph nodes
    Mittal, Saurabh
    Mohan, Anant
    Madan, Karan
    RESPIROLOGY, 2017, 22 (05) : 1037 - 1038
  • [47] Correlation study between apparent diffusion coefficients and the prognostic factors in breast cancer
    Dai, X.
    Shen, Y.
    Gao, Y.
    Huang, G.
    Lin, B.
    Liu, Y.
    CLINICAL RADIOLOGY, 2023, 78 (05) : 347 - 355
  • [48] SONOGRAPHIC FEATURES OF ENDOBRONCHIAL ULTRASOUND IN DIFFERENTIATION OF BENIGN LYMPH NODES
    Wang, Lei
    Wu, Weihua
    Teng, Jiajun
    Zhong, Runbo
    Han, Baohui
    Sun, Jiayuan
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (12): : 2785 - 2793
  • [49] The role of diffusion-weighted MR imaging in discrimination between benign and malignant axillary lymph nodes in breast cancer patients
    Amany Mohammed Hussein Zahran
    Rania Aly Maarouf
    Ahmed Hussein
    Aliaa Sayed Sheha
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [50] The role of diffusion-weighted MR imaging in discrimination between benign and malignant axillary lymph nodes in breast cancer patients
    Zahran, Amany Mohammed Hussein
    Maarouf, Rania Aly
    Hussein, Ahmed
    Sheha, Aliaa Sayed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01):