Validity and Reliability of a Novel Smartphone Tele-Assessment Solution for Quantifying Hip Range of Motion

被引:7
|
作者
Marshall, Charlotte J. [1 ]
El-Ansary, Doa [1 ,2 ]
Pranata, Adrian [1 ]
Ganderton, Charlotte [1 ]
O'Donnell, John [3 ]
Takla, Amir [3 ]
Tran, Phong [1 ,2 ,4 ]
Wickramasinghe, Nilmini [1 ]
Tirosh, Oren [1 ,4 ]
机构
[1] Swinburne Univ Technol, Sch Hlth Sci, Hawthorn, Vic 3122, Australia
[2] Univ Melbourne, Sch Med, Dept Surg, Parkville, Vic 3052, Australia
[3] Hip Arthroscopy Australia, Richmond, Vic 3121, Australia
[4] Footscray Hosp, Dept Orthopaed Surg, Western Hlth, Footscray, Vic 3011, Australia
关键词
tele-assessment; smartphone; hip range of motion; FEMOROACETABULAR IMPINGEMENT; JOINT RANGE; AGREEMENT; KNEE;
D O I
10.3390/s22218154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory's 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63-0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85-0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36-0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87-0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Validity and intra- and inter-rater reliability of the Tinetti performance-oriented mobility assessment balance subscale using different tele-assessment methods in patients with chronic stroke
    Onal, Birol
    Kose, Nezire
    Onal, Seyma Nur
    Zengin, Hatice Yagmur
    TOPICS IN STROKE REHABILITATION, 2024, 31 (06) : 547 - 555
  • [42] Reliability and Validity of a Novel Approach to Measure Hip Rotation
    Aefsky, Brett
    Fleet, Niles
    Myers, Heather
    Butler, Robert J.
    JOURNAL OF SPORT REHABILITATION, 2016, 25 (04) : 330 - 337
  • [43] Reliability and Validity of Cervical Range of Motion and Muscle Strength Testing
    Kubas, Christian
    Chen, Yi-Wen
    Echeverri, Silvana
    McCann, Stephanie L.
    Denhoed, Marcia J.
    Walker, Catherine J.
    Kennedy, Carol N.
    Reid, W. Darlene
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2017, 31 (04) : 1087 - 1096
  • [44] Within-day reliability of shoulder range of motion measurement with a smartphone
    Shin, Seung Han
    Ro, Du Hyun
    Lee, O-Sung
    Oh, Joo Han
    Kim, Sae Hoon
    MANUAL THERAPY, 2012, 17 (04) : 298 - 304
  • [45] Feasibility and validity of the push-up test for synchronous and asynchronous strength tele-assessment in spinal cord injury individuals with paraplegia
    Gomes Costa, Rodrigo Rodrigues
    Dorneles, Jefferson Rodrigues
    Carneiro Leao Veloso, Joao Henrique
    Passos Goncalves, Carlos Wellington
    Neto, Frederico Ribeiro
    JOURNAL OF SPINAL CORD MEDICINE, 2024, 47 (04): : 530 - 539
  • [46] Reliability of Hip Rotation Range of Motion in Supine and Seated Positions
    Gradoz, Marissa C.
    Bauer, Lauren E.
    Grindstaff, Terry L.
    Bagwell, Jennifer J.
    JOURNAL OF SPORT REHABILITATION, 2018, 27 (04) : 1 - 4
  • [47] Reliability of the Thomas test for assessing range of motion about the hip
    Peeler, J.
    Anderson, J. E.
    PHYSICAL THERAPY IN SPORT, 2007, 8 (01) : 14 - 21
  • [48] Reliability of the EasyAngle® for Assessing Hip Range of Motion in Healthy Children
    Duffy, Elana
    Wells, Maria
    Miller, Alan
    Tondra, Megan
    Doty, Antonette
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2024, 19 (01): : 1484 - 1493
  • [49] Novel Assessment of Isometric Hip Extensor Function: Reliability, Joint Angle Sensitivity, and Concurrent Validity
    Goodwin, Jon E.
    Bull, Anthony M. J.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2022, 36 (10) : 2762 - 2770
  • [50] Validity and reliability of two Smartphone applications to measure the lower and upper cervical spine range of motion in subjects with chronic cervical pain
    Rodriguez-Sanz, Jacobo
    Carrasco-Uribarren, Andoni
    Cabanillas-Barea, Sara
    Hidalgo-Garcia, Cesar
    Fanlo-Mazas, Pablo
    Orosia Lucha-Lopez, Maria
    Miguel Tricas-Moreno, Jose
    JOURNAL OF BACK AND MUSCULOSKELETAL REHABILITATION, 2019, 32 (04) : 619 - 627