Validity and Reliability of a Novel Smartphone Tele-Assessment Solution for Quantifying Hip Range of Motion

被引:7
|
作者
Marshall, Charlotte J. [1 ]
El-Ansary, Doa [1 ,2 ]
Pranata, Adrian [1 ]
Ganderton, Charlotte [1 ]
O'Donnell, John [3 ]
Takla, Amir [3 ]
Tran, Phong [1 ,2 ,4 ]
Wickramasinghe, Nilmini [1 ]
Tirosh, Oren [1 ,4 ]
机构
[1] Swinburne Univ Technol, Sch Hlth Sci, Hawthorn, Vic 3122, Australia
[2] Univ Melbourne, Sch Med, Dept Surg, Parkville, Vic 3052, Australia
[3] Hip Arthroscopy Australia, Richmond, Vic 3121, Australia
[4] Footscray Hosp, Dept Orthopaed Surg, Western Hlth, Footscray, Vic 3011, Australia
关键词
tele-assessment; smartphone; hip range of motion; FEMOROACETABULAR IMPINGEMENT; JOINT RANGE; AGREEMENT; KNEE;
D O I
10.3390/s22218154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Tele-health has become a major mode of delivery in patient care, with increasing interest in the use of tele-platforms for remote patient assessment. The use of smartphone technology to measure hip range of motion has been reported previously, with good to excellent validity and reliability. However, these smartphone applications did not provide real-time tele-assessment functionality. We developed a novel smartphone application, the TelePhysio app, which allows the clinician to remotely connect to the patient's device and measure their hip range of motion in real time. The aim of this study was to investigate the concurrent validity and between-sessions reliability of the TelePhysio app. In addition, the study investigated the concurrent validity, between-sessions, and inter-rater reliability of a second tele-assessment approach using video analysis. Methods: Fifteen participants (nfemales = 6) were assessed in our laboratory (session 1) and at their home (session 2). We assessed maximum voluntary active hip flexion in supine and hip internal and external rotation, in both prone and sitting positions. TelePhysio and video analysis were validated against the laboratory's 3-dimensional motion capture system in session 1, and evaluated for between-sessions reliability in session 2. Video analysis inter-rater reliability was assessed by comparing the analysis of two raters in session 2. Results: The TelePhysio app demonstrated high concurrent validity against the 3D motion capture system (ICCs 0.63-0.83) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.48, p = 0.99). The video analysis demonstrated almost perfect concurrent validity against the 3D motion capture system (ICCs 0.85-0.94) for all hip movements in all positions, with the exception of hip internal rotation in prone (ICC = 0.44, p = 0.01). The TelePhysio and video analysis demonstrated good between-sessions reliability for hip external rotation and hip flexion, ICC 0.64 and 0.62, respectively. The between-sessions reliability of hip internal and external rotation for both TelePhysio and video analysis was fair (ICCs 0.36-0.63). Inter-rater reliability ICCs for the video analysis were 0.59 for hip flexion and 0.87-0.95 for the hip rotation range. Conclusions: Both tele-assessment approaches, using either a smartphone application or video analysis, demonstrate good to excellent concurrent validity, and moderate to substantial between-sessions reliability in measuring hip rotation and flexion range of motion, but less in internal hip rotation in the prone position. Thus, it is recommended that the seated position be used when assessing hip internal rotation. The use of a smartphone to remotely assess hip range of motion is an appropriate, effective, and low-cost alternative to the face-to-face assessments. This method provides a simple, cost effective, and accessible patient assessment tool with no additional cost. This study validates the use of smartphone technology as a tele-assessment tool for remote hip range of motion assessment.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] A Study of Validity and Satisfaction of Tele-assessment
    Kim, Sung Jin
    Kang, Jin Kyong
    Kim, Young Tae
    Hong, Ki Hyung
    COMMUNICATION SCIENCES AND DISORDERS-CSD, 2023, 28 (02): : 372 - 385
  • [2] Validity of range of motion, muscle strength, sensitivity, and Tinel sign tele-assessment in adults with traumatic brachial plexus injury
    Andreia Gushikem
    Rodrigo Rodrigues Gomes Costa
    Ana Lucia Lima Cabral
    Luis Fernando Lopes Bomtempo
    Marcio de Mendonça Cardoso
    Acta Neurochirurgica, 2022, 164 : 1317 - 1328
  • [3] Validity of range of motion, muscle strength, sensitivity, and Tinel sign tele-assessment in adults with traumatic brachial plexus injury
    Gushikem, Andreia
    Gomes Costa, Rodrigo Rodrigues
    Lima Cabral, Ana Lucia
    Lopes Bomtempo, Luis Fernando
    Cardoso, Marcio de Mendonca
    ACTA NEUROCHIRURGICA, 2022, 164 (05) : 1317 - 1328
  • [4] Tele-Assessment of Functional Capacity: Validity, Intra- and Inter-rater Reliability
    Asliyüce, Yasemin Ozel
    Fanuscu, Aybuke
    Asliyüce, Abdurahim
    Ülger, Ozlem
    WORKPLACE HEALTH & SAFETY, 2023, 71 (10) : 476 - 483
  • [5] Tele-assessment of core performance and functional capacity: Reliability, validity, and feasibility in healthy individuals
    Gungor, Feray
    Ovacik, Ugur
    Harputlu, Ozge Ertan
    Yekdaneh, Ayse Asena
    Kurt, Irem
    Uzunoglu, Gamze Erturk
    Ilguz, Basak Polat
    Akuzum, Funda
    Akbaba, Yildiz Analay
    JOURNAL OF TELEMEDICINE AND TELECARE, 2024, 30 (06) : 1017 - 1025
  • [6] VALIDITY AND RELIABILITY OF A SMARTPHONE GONIOMETER APPLICATION FOR MEASURING HIP RANGE OF MOTION IN PATIENTS WITH HIP OSTEOARTHRITIS: A PILOT STUDY
    Sarac, D. C.
    Yalcinkaya, G.
    Unver, B.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 1531 - 1531
  • [7] Evidence for the reliability and validity of a Spanish translation of the Medication Management Ability Assessment administered via tele-assessment
    Garcia, Joshua M.
    Mejia, Yenifer L. Morales
    Lopez, Andrea P. Ochoa
    Woods, Steven Paul
    Valier, Helen
    Medina, Luis D.
    APPLIED NEUROPSYCHOLOGY-ADULT, 2024, 31 (06) : 1192 - 1204
  • [8] Reliability and concurrent validity of a Smartphone, bubble inclinometer and motion analysis system for measurement of hip joint range of motion
    Charlton, Paula C.
    Mentiplay, Benjamin F.
    Pua, Yong-Hao
    Clark, Ross A.
    JOURNAL OF SCIENCE AND MEDICINE IN SPORT, 2015, 18 (03) : 262 - 267
  • [9] Validity and Reliability of Inertial Measurement Units in Active Range of Motion Assessment in the Hip Joint
    Stolowski, Lukasz
    Niedziela, Maciej
    Lubiatowski, Bartlomiej
    Lubiatowski, Przemyslaw
    Piontek, Tomasz
    SENSORS, 2023, 23 (21)
  • [10] Validity and reliability of a smartphone goniometer application for measuring hip range of motions
    Sarac, Devrim Can
    Yalcinkaya, Gamze
    Unver, Bayram
    WORK-A JOURNAL OF PREVENTION ASSESSMENT & REHABILITATION, 2022, 71 (01): : 275 - 280