Region-segmentation strategy for Bruch's membrane opening detection in spectral domain optical coherence tomography images

被引:6
|
作者
Chen, Zailiang [1 ]
Peng, Peng [1 ]
Shen, Hailan [1 ]
Wei, Hao [1 ]
Ouyang, Pingbo [2 ]
Duan, Xuanchu [3 ]
机构
[1] Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
[2] Cent S Univ, Xiangya Hosp 2, Changsha 410011, Hunan, Peoples R China
[3] Changsha Aier Eye Hosp, Changsha 410015, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
FIBER LAYER THICKNESS; OPEN-ANGLE GLAUCOMA; LAMINA-CRIBROSA; SD-OCT; AUTOMATED SEGMENTATION; DISC; CUP; QUANTIFICATION; DEPTH;
D O I
10.1364/BOE.10.000526
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bruch's membrane opening (BMO) is an important biomarker in the progression of glaucoma. Bruch's membrane opening minimum rim width (BM-MRW), cup-to-disc ratio in spectral domain optical coherence tomography (SD-OCT) and lamina cribrosa depth based on BMO are important measurable parameters for glaucoma diagnosis. The accuracy of measuring these parameters is significantly affected by BMO detection. In this paper, we propose a method for automatically detecting BMO in SD-OCT volumes accurately to reduce the impact of the border tissue and vessel shadows. The method includes three stages: a coarse detection stage composed by retinal pigment epithelium layer segmentation, optic disc segmentation, and multi-modal registration; a fixed detection stage based on the U-net in which BMO detection is transformed into a region segmentation problem and an area bias component is proposed in the loss function; and a post-processing stage based on the consistency of results to remove outliers. Experimental results show that the proposed method outperforms previous methods and achieves a mean error of 42.38 mu m. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:526 / 538
页数:13
相关论文
共 50 条
  • [11] Repeatability of Spectral Domain Optical Coherence Tomography Measurements of Bruch's Membrane Opening-Minimum Rim Width in Epiretinal Membrane Patients with Peripapillary Involvement
    Nam, Ki Yup
    Kim, Bum Jun
    Lee, Woo Hyuk
    Han, Yong Seop
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (11)
  • [12] Fast retinal layer segmentation of spectral domain optical coherence tomography images
    Zhang, Tianqiao
    Song, Zhangjun
    Wang, Xiaogang
    Zheng, Huimin
    Jia, Fucang
    Wu, Jianhuang
    Jia, Fucang
    Wu, Jianhuang
    Li, Guanglin
    Hu, Qingmao
    JOURNAL OF BIOMEDICAL OPTICS, 2015, 20 (09)
  • [13] Measurement of the Optic Nerve Head Descending Fibers at Bruch's Membrane Opening Level with Spectral Domain Optical Coherence Tomography in Normal and Glaucoma Eyes
    Fagundes Fujihara, Fernanda Mari
    de Arruda Mello, Paulo Augusto
    Benfica, Camila Zanella
    Castoldi, Nedio
    Mendes, Fernanda Miranda
    Finkelstein, Alessandro
    Lindenmeyer, Rodrigo Leivas
    Lavinsky, Daniel
    Pakter, Helena Messinger
    Lavinsky, Fabio
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (11)
  • [14] Spectral-Domain Optical Coherence Tomography-Derived Characteristics of Bruch Membrane Opening in a Young Adult Australian Population REPLY
    Sanfilippo, Paul Gerard
    Huynh, Emily
    Yazar, Seyhan
    Hewitt, Alex William
    Mackey, David Anthony
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 174 : 179 - 179
  • [15] THE OUTER BRUCH MEMBRANE LAYER A Previously Undescribed Spectral-Domain Optical Coherence Tomography Finding
    Bloom, Steven M.
    Singal, Inder P.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (02): : 316 - 323
  • [16] The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs
    Enders, Philip
    Schaub, Friederike
    Adler, Werner
    Nikoluk, Roman
    Hermann, Manuel M.
    Heindl, Ludwig M.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2017, 101 (04) : 530 - 535
  • [17] Segmentation of the Geographic Atrophy in Spectral-Domain Optical Coherence Tomography and Fundus Autofluorescence Images
    Hu, Zhihong
    Medioni, Gerard G.
    Hernandez, Matthias
    Hariri, Amirhossein
    Wu, Xiaodong
    Sadda, SriniVas R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (13) : 8375 - 8383
  • [18] Influence of Bruch's Membrane Opening Area in Diagnosing Glaucoma With Neuroretinal Parameters From Optical Coherence Tomography
    Torres, Lucas A.
    Sharpe, Glen P.
    Hutchison, Donna M.
    Zangalli, Camila S.
    Burk, Reinhard O.
    Reis, Alexandre S. C.
    Costa, Vital P.
    Nicolela, Marcelo T.
    Chauhan, Balwantray C.
    Vianna, Jayme R.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 208 : 94 - 102
  • [19] Reproducibility of Bruch's membrane opening-minimum rim width measurements with Spectralis optical coherence tomography
    Lee, Jiwoong
    Park, Keunheung
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [20] Balanced detection for spectral domain optical coherence tomography
    Kuo, Wen-Chuan
    Lai, Chih-Ming
    Huang, Yi-Shiang
    Chang, Cheng-Yi
    Kuo, Yue-Ming
    OPTICS EXPRESS, 2013, 21 (16): : 19280 - 19291