Data acquisition system for Doppler radar vital-sign monitor

被引:4
|
作者
Vergara, Alexander M. [1 ]
Lubecke, Victor M. [2 ]
机构
[1] Univ Hawaii Manoa, Honolulu, HI 96822 USA
[2] Univ Hawaii Manoa, Dept Elect Engn, Honolulu, HI 96822 USA
关键词
D O I
10.1109/IEMBS.2007.4352777
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic gain control (AGC) units increase the dynamic range of a system to compensate for the limited dynamic range of analog to digital converters. This problem is compounded in wireless systems in which large changes in signal strength are effects of a changing environment. These issues are evident in the direct-conversion Doppler radar vital-sign monitor. Utilizing microwave radar signals reflecting off a human subject, a two-channel quadrature receiver can detect periodic movement resulting from cardio-pulmonary activity. The quadrature signal is analyzed using an arctangent demodulation that extracts vital phase information. A data acquisition (DAQ) system is proposed to deal with issues inherent in arctangent demodulation of a quadrature radar signal.
引用
收藏
页码:2269 / +
页数:2
相关论文
共 50 条
  • [31] A Broadband MFCW Agile Radar Concept for Vital-Sign Detection Under Various Thoracic Movements
    Lin, Yi-Hsien
    Cheng, Jen-Hao
    Chang, Li-Chi
    Lin, Wen-Jie
    Tsai, Jeng-Han
    Huang, Tian-Wei
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2022, 70 (08) : 4056 - 4070
  • [32] Understanding vital-sign abnormalities in critical care patients
    S Hugueny
    DA Clifton
    M Hravnak
    MR Pinsky
    L Tarassenko
    Critical Care, 14 (Suppl 1):
  • [33] Data acquisition module of radar condition monitor and fault diagnosis system
    Xue, J
    Cai, JY
    Ma, SS
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 7699 - 7702
  • [34] A Portable 24GHz Doppler Radar System for Distant Human Vital Sign Monitoring
    Li, Po
    Huo, Nan
    2018 5TH INTERNATIONAL CONFERENCE ON INFORMATION SCIENCE AND CONTROL ENGINEERING (ICISCE 2018), 2018, : 1050 - 1052
  • [35] DIRECT CONVERSION DOPPLER RADAR VITAL SIGN DETECTION SYSTEM USING POWER MANAGEMENT TECHNIQUE
    Lee, Chie-In
    Lin, Yan-Ting
    Chen, Jhih-Jie
    Lin, Wei-Cheng
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2014, 56 (09) : 2167 - 2174
  • [36] Vital-Sign Characteristics of an Elderly Person during Walking
    Oyabu, Takashi
    Kajiwara, Yusuke
    Kimura, Haruhiko
    SENSORS AND MATERIALS, 2016, 28 (04) : 379 - 388
  • [37] IR-UWB Radar Demonstrator for Ultra-Fine Movement Detection and Vital-Sign Monitoring
    Schleicher, Bernd
    Nasr, Ismail
    Trasser, Andreas
    Schumacher, Hermann
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (05) : 2076 - 2085
  • [38] Vital-sign monitoring and spatial tracking of multiple people using a contactless radar-based sensor
    Mercuri, Marco
    Lorato, Ilde Rosa
    Liu, Yao-Hong
    Wieringa, Fokko
    Van Hoof, Chris
    Torfs, Tom
    NATURE ELECTRONICS, 2019, 2 (06) : 252 - +
  • [39] Real-Time & Autonomous Data Transmission for Vital-Sign Telemonitoring: Requirements & Conceptualization
    Schweitzer, Marco
    Huber, Lukas
    Gorfer, Thilo
    Hoerbst, Alexander
    GERMAN MEDICAL DATA SCIENCES: SHAPING CHANGE - CREATIVE SOLUTIONS FOR INNOVATIVE MEDICINE (GMDS 2019), 2019, 267 : 28 - 36
  • [40] Wearable Doppler Radar with Integrated Antenna for Patient Vital Sign Monitoring
    Ebrahimian, Homayoun
    ELECTROMAGNETICS, 2017, 37 (04) : 240 - 256