A precision length measuring system for a variety of linear artefacts

被引:12
|
作者
Eom, TB [1 ]
Han, JW [1 ]
机构
[1] Korea Res Inst Stand & Sci, Length Grp, Yousong 305600, Taejeon, South Korea
关键词
end standard. line standard; Abbe offset; cosine error; plane mirror interferometer; step gauge; monolithic flexure structure;
D O I
10.1088/0957-0233/12/6/307
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To calibrate precision length standards and length measuring transducers, the Korea Research Institute of Standards and Science (KRISS) has built a new linear measuring machine. The main requirement on the machine is to achieve sufficient flexibility to be able to calibrate a variety of standards such as step gauges, long-range linear transducers, industrial line scales and end bars with high accuracy. This system is not designed for calibrating primary standards such as a gauge block or a primary standard line scale. which are usually measured by specially designed precise interferometers. The main parts of the system are a precision stage and a laser interferometer. For smooth motion and precise positioning, we have built double stages, which consist of a global stage with an air bearing and a micro-stage with a flexure structure. Furthermore. two tilting stages are used for compensating for the pitch motion and the yaw motion of the global stage. Two double-pass plane mirror interferometers based on the heterodyne technique measure the displacement of the stage. The Abbe offset error is minimized by two interferometers with double-pass arrangements and two servo-controlled tilting stages. The measuring range of the system is 2500 mm and the expanded uncertainty for 1000 mm end bar calibration is 0.8 mum at the 95% confidence level.
引用
收藏
页码:698 / 701
页数:4
相关论文
共 50 条
  • [31] A PHOTOSENSOR-BASED MEASURING SYSTEM FOR PRECISION MECHANICS
    MAROLA, G
    SCHIAFFINO, M
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1983, 32 (02) : 387 - 388
  • [32] A PRECISION ISOTONIC MEASURING SYSTEM FOR ISOLATED-TISSUES
    MELLOR, PM
    JOURNAL OF PHARMACOLOGICAL METHODS, 1984, 12 (04): : 259 - 264
  • [33] Design of angular displacement measuring system for precision reducer
    Lu Y.
    Qiu Z.
    You Y.
    Xue J.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2021, 42 (07): : 14 - 20
  • [34] A NOVEL PRECISION TYPE LIQUID CONDUCTIVITY MEASURING SYSTEM
    REHMAN, M
    MURTI, VGK
    GUPTA, MR
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1985, 18 (11): : 902 - 903
  • [35] Study on angular measuring system for the precision testing turntable
    School of Astronautics, Harbin Institute of Technology, Harbin 150001, China
    Harbin Gongye Daxue Xuebao, 2006, 2 (167-169+318):
  • [36] Design of the high precision liquid level measuring system
    Ma, Hong
    PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2017), 2017, 143 : 1325 - 1328
  • [37] Tests of a precision tiltmeter system for measuring telescope position
    Kibrick, R
    Robinson, L
    Wallace, V
    Cowley, D
    TELESCOPE CONTROL SYSTEMS III, 1998, 3351 : 342 - 353
  • [38] A Computer Controlled Precision High Pressure Measuring System
    Sadana, S.
    Yadav, S.
    Jha, N.
    Gupta, V. K.
    Agarwal, R.
    Bandyopadhyay, A. K.
    Saxena, T. K.
    MEASUREMENT SCIENCE REVIEW, 2011, 11 (06): : 198 - 202
  • [39] PRECISION DISTANCE MEASURING EQUIPMENT FOR THE MICROWAVE LANDING SYSTEM
    BECKER, K
    MULLER, A
    VOGEL, H
    ELECTRICAL COMMUNICATION, 1984, 58 (03): : 336 - 343
  • [40] Development of Precision Information Measuring System for Ultraviolet Radiation
    Roshchupkin, Oleksiy
    Smid, Radislav
    Sachenko, Anatoliy
    Kochan, Volodymyr
    ADVANCES IN ELECTRICAL AND COMPUTER ENGINEERING, 2014, 14 (03) : 101 - 106