Full-scale experimental and numerical studies on compartment fire under low ambient temperature

被引:41
|
作者
Bystrom, Alexandra [1 ]
Cheng, Xudong [1 ,2 ]
Wickstrom, Ulf [1 ,3 ]
Veljkovic, Milan [1 ]
机构
[1] Lulea Univ Technol, Div Struct & Construct Engn, SE-97187 Lulea, Sweden
[2] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Peoples R China
[3] Swedish Natl Testing & Res Inst SP, Boras, Sweden
关键词
Compartment fire; Temperature distribution; FDS; Low ambient temperature; SIMULATION; FDS;
D O I
10.1016/j.buildenv.2011.11.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A fire experiment with wood crib was conducted in a concrete building under low ambient temperature of -10 degrees C to explore fire development and temperature distribution. The concrete building consists of a two-storey compartment with the size of 9.0 m by 5.0 m by 4.8 m high and a four-storey stairwell with the size of 5.0 m by 2.4 m by 10.0 m high. The fuel mass loss rate and temperatures at different positions were measured. Two fire cases, with different assumed ambient temperatures of -10 degrees C and 20 degrees C respectively, were then simulated by using FDS software to investigate the effect of ambient temperature and compare with the experimental results. The numerical results show that the calculated heat release rate is in reasonably good agreement with the measured full-scale result before water suppression. The calculated temperatures in the hot combustion gas layer at different positions agree also very well with the measured values. However, the measured fresh air temperature at the floor level near the fire source is higher than the calculated value. This discrepancy may partly depend on measuring errors as analyzed in the paper. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:255 / 262
页数:8
相关论文
共 50 条
  • [31] Temperature measurement errors in full-scale tunnel fire experiments
    Chen J.
    Cheng H.
    Wei X.
    Wen Q.
    Wu L.
    Liu C.
    Zhong M.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2022, 62 (10): : 1618 - 1625
  • [32] Flame spread and smoke temperature of full-scale fire test of car fire
    Li, Dayan
    Zhu, Guoqing
    Zhu, Hui
    Yu, Zhichao
    Gao, Yunji
    Jiang, Xiaohui
    CASE STUDIES IN THERMAL ENGINEERING, 2017, 10 : 315 - 324
  • [33] Full-scale Experimental Study on Smoke Temperature and Fire Characteristics Occurred at Deflected Positions in Tunnels
    Hu J.-W.
    Mao J.
    Liu B.
    Lin Z.-Y.
    Xi Y.-H.
    Li G.-Q.
    Guo R.-J.
    Mao, Jun (jmao@bjtu.edu.cn), 1600, Chang'an University (33): : 205 - 214
  • [34] Experimental study on safety full-scale of tunnel fire disaster under different blocking conditions
    Tian X.
    Zhong M.
    Liu C.
    Li Q.
    Meitan Kexue Jishu/Coal Science and Technology (Peking), 2021, 49 (02): : 93 - 101
  • [35] Experimental and numerical investigation of a full-scale multistorey RC building under dynamic loading
    Iskhakov, I
    Ribakov, Y
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2005, 14 (04): : 299 - 313
  • [36] Structural Failure of Reinforced Concrete Bearing Walls under Fire: A Full-Scale Experimental Investigation
    Mueller, Kevin A.
    Kurama, Yahya C.
    RESPONSE OF STRUCTURES UNDER EXTREME LOADING, 2015, : 677 - 685
  • [37] Thermal and structural behaviour of a full-scale composite building subject to a severe compartment fire
    Foster, Samantha
    Chladna, Magdalena
    Hsieh, Christina
    Burgess, Ian
    Plank, Roger
    FIRE SAFETY JOURNAL, 2007, 42 (03) : 183 - 199
  • [38] Experimental Study on Jatropha Oil Pool Fire in Full Scale Compartment
    Chaudhary, Avinash
    Gupta, Akhilesh
    Kumar, Surendra
    Kumar, Ravi
    BIOFUELS AND BIOENERGY (BICE2016), 2017, : 191 - 201
  • [39] Experimental and numerical studies on predicting and improving the full-scale wastewater treatment plant hydrodynamics
    Sibil, Rahim
    Aras, Egemen
    Kankal, Murat
    DESALINATION AND WATER TREATMENT, 2021, 237 : 1 - 17
  • [40] Numerical and theoretical evaluations of the propagation of smoke and fire in a full-scale tunnel
    Wang, H. Y.