The in vitro and in vivo reproducibility of a video-based digital imaging system for tooth colour measurement

被引:6
|
作者
Luo, Wen [1 ]
Naeeni, Mojgan [1 ]
Platten, Suzanne [1 ]
Wang, Jinfang [2 ]
Sun, Jianing N. [2 ]
Westland, Stephen [3 ]
Joiner, Andrew [1 ]
机构
[1] Unilever Oral Care, Quarry Rd East, Wirral CH63 3JW, Merseyside, England
[2] Unilever Oral Care, 66 Linxin Rd, Shanghai 200335, Peoples R China
[3] Univ Leeds, Woodhouse Lane, Leeds LS2 9JT, W Yorkshire, England
关键词
Colour; Tooth whiteness; Repeatability; Reproducibility; Clinical; DENTISTRY; WHITENESS; SPECTRORADIOMETER; CIELAB; STAIN;
D O I
10.1016/j.jdent.2017.09.012
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess the robustness of a new custom built video-based digital imaging system (VDIS) for measuring tooth colour and whiteness under in vitro and in vivo conditions. Methods: The VDIS imaging system was developed for tooth colour measurement and evaluated in vitro and in vivo. The in vitro validation used extracted human teeth (HT, n= 14) stored in water and VITA Classical shade guide tabs (SG, n = 16). These were measured by the VDIS at baseline, 5 min, 2 h, 1 week and 2 weeks to evaluate the system repeatability. For in vivo validation, adult volunteers (male/female, n= 34) with two natural, unrestored central incisors had their teeth imaged using the VDIS at baseline, 5 min and 2 h (3 images each) by two different operators to evaluate time and operator effects. Between taking individual images, subjects moved from the imaging-frame to assess the effect of re-positioning on reproducibility. From the in vitro and in vivo images, the average tooth RGB values were obtained, and the CIELAB values and a tooth whiteness index WIO value were calculated. Repeatability and reproducibility of VDIS imaging system was assessed using appropriate repeated measurement analysis techniques and ANOVA. Results: The measurement variations in vitro were between 1 and 2 units of.WIO and the average colour differences were less than 1 Delta E*(ab) unit. For the in vivo study, analysis of the CIELAB parameters and WIO showed that subject variability accounted for between 82 and 99% of the observed variability in the measurement process. The operator variability was less than 0.5% and the overall measurement error was found to be only 0.3% for WIO. Across assessment times the variability was less than 0.5%. Conclusions: The dental imaging system V-DIS was shown to be a highly reproducible means for tooth colour and whiteness measurement.
引用
收藏
页码:S15 / S19
页数:5
相关论文
共 50 条
  • [21] Video-Based Stress Level Measurement Using
    Mitsuhashi, Ryota
    Iuchi, Kaito
    Goto, Takashi
    Matsubara, Akira
    Hirayama, Takahiro
    Hashizume, Hideki
    Tsumura, Norimichi
    2019 IEEE INTERNATIONAL CONFERENCE ON MULTIMEDIA & EXPO WORKSHOPS (ICMEW), 2019, : 90 - 95
  • [22] Reproducibility of In Vivo Magnetic Resonance Imaging-Based Measurement of Myelin Water
    Levesque, Ives R.
    Chia, Charmaine L. L.
    Pike, G. Bruce
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 32 (01) : 60 - 68
  • [23] Video-based traffic monitoring system
    Chang, ECP
    ENHANCED AND SYNTHETIC VISION 1998, 1998, 3364 : 273 - 277
  • [24] A video-based drowning detection system
    Kam, AH
    Lu, WM
    Yau, WY
    COMPUTER VISION - ECCV 2002, PT IV, 2002, 2353 : 297 - 311
  • [25] Active video-based surveillance system
    Foresti, GL
    Micheloni, C
    Snidaro, L
    Remagnino, P
    Ellis, T
    IEEE SIGNAL PROCESSING MAGAZINE, 2005, 22 (02) : 25 - 37
  • [26] A Video-Based Augmented Reality System
    Motokurumada, Masataka
    Ohta, Masaya
    Yamashita, Katsumi
    2013 IEEE 17TH INTERNATIONAL SYMPOSIUM ON CONSUMER ELECTRONICS (ISCE), 2013, : 213 - 214
  • [27] A video-based theodolite simulation system
    Jian, Zhong
    Zhe, Zheng
    ADVANCES IN APPLIED SCIENCE AND INDUSTRIAL TECHNOLOGY, PTS 1 AND 2, 2013, 798-799 : 272 - 275
  • [28] A LOW-COST VIDEO-BASED MULTIPLE-TARGET DIGITAL TRACKING SYSTEM
    CHELIHI, N
    GAYDECKI, PA
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (04) : 447 - 450
  • [29] Bread crust thickness measurement using digital imaging and L a b colour system
    Jusoh, Y. M. Mohd
    Chin, N. L.
    Yusof, Y. A.
    Rahman, R. Abdul
    JOURNAL OF FOOD ENGINEERING, 2009, 94 (3-4) : 366 - 371
  • [30] Tooth colour measurement by image analysis: system development.
    Guan, YH
    Lath, DL
    Lilley, TH
    Brook, AH
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 530 - 530