High performance computing for deformable image registration:: Towards a new paradigm in adaptive radiotherapy

被引:88
|
作者
Samant, Sanjiv S. [1 ]
Xia, Junyi [1 ]
Muyan-Oezcelilk, Pinar [2 ]
Owens, John D. [2 ]
机构
[1] Univ Florida, Dept Nucl & Radiol Engn, Gainesville, FL 32611 USA
[2] Univ Calif Davis, Dept Elect & Comp Engn, Davis, CA 95616 USA
关键词
high performance computing; deformable image registration; demons; graphics processing unit; general purpose computation; GPU; GPGPU;
D O I
10.1118/1.2948318
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The advent of readily available temporal imaging or time series volumetric (4D) imaging has become an indispensable component of treatment planning and adaptive radiotherapy (ART) at many radiotherapy centers. Deformable image registration (DIR) is also used in other areas of medical imaging, including motion corrected image reconstruction. Due to long computation time, clinical applications of DIR in radiation therapy and elsewhere have been limited and consequently relegated to offline analysis. With the recent advances in hardware and software, graphics processing unit (GPU) based computing is an emerging technology for general purpose computation, including DIR, and is suitable for highly parallelized computing. However, traditional general purpose computation on the GPU is limited because the constraints of the available programming platforms. As well, compared to CPU programming, the GPU currently has reduced dedicated processor memory, which can limit the useful working data set for parallelized processing. We present an implementation of the demons algorithm using the NVIDIA 8800 GTX GPU and the new CUDA programming language. The GPU performance will be compared with single threading and multithreading CPU implementations on an Intel dual core 2.4 GHz CPU using the C programming language. CUDA provides a C-like language programming interface, and allows for direct access to the highly parallel compute units in the GPU. Comparisons for volumetric clinical lung images acquired using 4DCT were carried out. Computation time for 100 iterations in the range of 1.8-13.5 s was observed for the GPU with image size ranging from 2.0x10(6) to 14.2x10(6) pixels. The GPU registration was 55-61 times faster than the CPU for the single threading implementation, and 34-39 times faster for the multithreading implementation. For CPU based computing, the computational time generally has a linear dependence on image size for medical imaging data. Computational efficiency is characterized in terms of time per megapixels per iteration (TPMI) with units of seconds per megapixels per iteration (or spmi). For the demons algorithm, our CPU implementation yielded largely invariant values of TPMI. The mean TPMIs were 0.527 spmi and 0.335 spmi for the single threading and multithreading cases, respectively, with < 2% variation over the considered image data range. For GPU computing, we achieved TPMI=0.00916 spmi with 3.7% variation, indicating optimized memory handling under CUDA. The paradigm of GPU based real-time DIR opens up a host of clinical applications for medical imaging. (c) 2008 American Association of Physicists in Medicine.
引用
收藏
页码:3546 / 3553
页数:8
相关论文
共 50 条
  • [21] A Contour-guided Demons Deformable Image Registration Algorithm For Adaptive Radiotherapy
    Gu, X.
    Jia, X.
    Dong, B.
    Gautier, Q.
    Jiang, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S803 - S804
  • [22] ADAPTIVE RADIOTHERAPY USING DEFORMABLE IMAGE REGISTRATION - A CONCEPT FOR INDIVIDUALISED RADIATION TREATMENTS
    Winkler, P.
    Jakse, G.
    Lodron, G.
    Uray, M.
    Mayer, H.
    Kapp, K. S.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [23] A QA method for evaluation of deformable image registration in head and neck adaptive radiotherapy
    Cagni, E.
    Botti, A.
    Orlandi, M.
    Galaverni, M.
    Sghedoni, R.
    Iotti, C.
    Spezi, E.
    Iori, M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1101 - S1101
  • [24] Dosimetric Study of the Deformable Image Registration based Lung Cancer Adaptive Radiotherapy
    Wang, Linjing
    Zhang, Shuxu
    Yuan, Kehong
    Zhou, Lu
    Wang, Ruihao
    2015 8TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI), 2015, : 402 - 406
  • [25] Quality Assurance of Deformable Image Registration in Radiotherapy
    Watkins, W. T.
    Bzdusek, K.
    Siebers, J. V.
    MEDICAL PHYSICS, 2014, 41 (06) : 399 - 399
  • [26] The ANACONDA algorithm for deformable image registration in radiotherapy
    Weistrand, Ola
    Svensson, Stina
    MEDICAL PHYSICS, 2015, 42 (01) : 40 - 53
  • [27] Deformable Image Registration in the Radiotherapy of Breast Cancer
    Duma, M. N.
    Pargmann, L.
    Volkel-Beltran, S.
    Boehm, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2022, 198 (SUPPL 1) : S101 - S101
  • [28] Deformable image registration for breast cancer radiotherapy
    Duma, M. N.
    Pargmann, L.
    Boehm, M.
    Wittig, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1043 - S1044
  • [29] High-performance computing in image registration
    Zanin, Michele
    Remondino, Fabio
    Dalla Mura, Mauro
    HIGH-PERFORMANCE COMPUTING IN REMOTE SENSING II, 2012, 8539
  • [30] Assessing the feasibility of adaptive planning for prostate radiotherapy using Smartadapt deformable image registration
    Anaya, Virginia Marin
    Fairfoul, Jamie
    MEDICAL ENGINEERING & PHYSICS, 2019, 64 : 65 - 73