Development and characterization of a handheld radiation detector for radio-guided surgery

被引:2
|
作者
Bedir, M. E. [1 ,2 ]
Thomadsen, B. R. [1 ]
Bednarz, B. P. [1 ]
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Wisconsin Inst Med Res 1005, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[2] Karamanoglu Mehmetbey Univ, Coll Tech Sci, Dept Elect & Energy, TR-70100 Karaman, Turkey
关键词
Lanthanum bromide crystal; MCNPX simulations; Handheld gamma detector; Surgical localization; Breast cancer; Silicon photomultipliers; TECHNOLOGY; NAI(TL);
D O I
10.1016/j.radmeas.2020.106362
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The current state-of-the-art breast surgery uses radioactive brachytherapy sources to indicate the center of the tumor and possibly a few points on the periphery as seen on mammography. Since such guidance is very coarse, tumor free margins are not achievable in many cases and a re-excision procedure is often required. Better radiation guidance (radio-guidance) could come from labelling cancer cells directly with a radionuclide, such as the agent CLR1404. The agent CLR1404 is taken up by breast cancer cells but not normal cells and, labelled with radioactive I-123, could image the whole tumor, not just points. Tc-99m-labelled nanoparticles are used to locate sentinel lymph nodes. Simultaneous detection and differentiation of the photon energies 159 keV from I-123 and 141 keV from Tc-99m requires a radiation detector with high energy resolution and sufficient efficiency. This report involves the design, development and characterization of such a handheld radiation detector. Following the design and integration of the detector, the main characteristics of the detector, such as energy resolution, photopeak efficiency and response at different source-to-detector distances were investigated experimentally. Energy resolution of the detector was found to be less than 10 keV (FWHM) at energies below 159 keV, which allowed discerning the radiation from the two radionuclides. Energy spectra of the radioactive sources acquired experimentally were compared to those simulated in Monte Carlo N-Particle Transport Code (MCNP6X). The detector developed was found to be promising for radiation-guided surgery applications.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Radio-guided thoracoscopic surgery (RGTS) of small pulmonary nodules
    Marcello Carlo Ambrogi
    Franca Melfi
    Carmelina Zirafa
    Marco Lucchi
    Annalisa De Liperi
    Giuliano Mariani
    Olivia Fanucchi
    Alfredo Mussi
    Surgical Endoscopy, 2012, 26 : 914 - 919
  • [32] An Intraoperative β- Detecting Probe for Radio-Guided Surgery in Tumour Resection
    Russomando, Andrea
    Bellini, Fabio
    Bocci, Valerio
    Collamati, Francesco
    De Lucia, Erika
    Faccini, Riccardo
    Marafini, Michela
    Mattei, Ilaria
    Chiodi, Giacomo
    Patera, Vincenzo
    Recchia, Luigi
    Sarti, Alessio
    Sciubba, Adalberto
    Camillocci, Elena Solfaroli
    Paramatti, Riccardo
    Voena, Cecilia
    Donnarumma, Raffaella
    Mancini-Terracciano, Carlo
    Morganti, Silvio
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (05) : 2533 - 2539
  • [33] Use of bremsstrahlung radiation to identify hidden weak β- sources: feasibility and possible use in radio-guided surgery
    Carlotti, D.
    Collamati, F.
    Faccini, R.
    Fresch, P.
    Iacoangeli, F.
    Mancini-Terracciano, C.
    Marafini, M.
    Mirabelli, R.
    Recchia, L.
    Russomando, A.
    Camillocci, E. Solfaroli
    Toppi, M.
    Traini, G.
    Bocci, V.
    JOURNAL OF INSTRUMENTATION, 2017, 12
  • [34] Experienced radio-guided surgery teams can successfully perform minimally invasive radio-guided parathyroidectomy without Intraoperative parathyroid hormone assays
    Caudle, Abigail S.
    Brier, Sarah E.
    Calvo, Benjamin F.
    Kim, Hong Jin
    Meyers, Michael O.
    Ollila, David W.
    AMERICAN SURGEON, 2006, 72 (09) : 785 - 789
  • [35] Radio-Guided Lung Surgery: A Feasible Approach for a Cancer Precision Medicine
    Conte, Miriam
    De Feo, Maria Silvia
    Frantellizzi, Viviana
    Tomaciello, Miriam
    Marampon, Francesco
    Evangelista, Laura
    Filippi, Luca
    De Vincentis, Giuseppe
    DIAGNOSTICS, 2023, 13 (16)
  • [36] Multidisciplinary radio-guided surgery team: Alternative to change the current paradigm
    Ribera-Perianes, J.
    Vega, M.
    Moreno, X. Cases
    Cordon, J.
    Gracia, J. Cortes
    Paredes, P.
    Sanchez-Izquierdo, N.
    Perissinotti, A.
    Pelfort, D. Fuster
    Vidal-Sicart, S.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2024, 43 (02): : 91 - 99
  • [37] First Experiences with Navigated Radio-Guided Surgery Using Freehand SPECT
    Rieger, A.
    Saeckl, J.
    Belloni, B.
    Hein, R.
    Okur, A.
    Scheidhauer, K.
    Wendler, T.
    Traub, J.
    Friess, H.
    Martignoni, M. E.
    CASE REPORTS IN ONCOLOGY, 2011, 4 (02): : 420 - 425
  • [38] PSMA-PET-MRI and radio-guided surgery in cervical lymphadenectomy
    Lingl, Julia P.
    Boehm, Felix
    Wiegel, Thomas
    Beer, Ambros J.
    Hoffmann, Thomas K.
    HNO, 2022, 70 (12) : 907 - 910
  • [39] Radio-guided Surgery for Lymph Node Recurrences of Differentiated Thyroid Cancer
    Massimo Salvatori
    Vittoria Rufini
    Francesca Reale
    Ana Maria Samanes Gajate
    Maria Lodovica Maussier
    Luca Revelli
    Luigi Troncone
    Guglielmo Ardito
    World Journal of Surgery, 2003, 27 : 770 - 775
  • [40] Radio-guided surgery in differentiated thyroid cancer: Report of four cases
    Kallel, F.
    Hamza, F.
    Charfeddine, S.
    Ghorbel, A.
    Guermazi, F.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2009, 33 (10): : 646 - 649