Dosimetric Assessment of Using Brass Mesh Bolus with High Energy X-Ray Beams

被引:0
|
作者
Manger, R. [1 ]
Yock, A. [1 ]
Soultan, D. [1 ]
Harry, T. [1 ]
Cervino, L. [1 ]
机构
[1] Univ Calif San Diego, San Diego, CA 92103 USA
关键词
D O I
10.1118/1.4924659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:3401 / 3401
页数:1
相关论文
共 50 条
  • [21] Experimental determination of the dose kernel in high-energy x-ray beams
    Ceberg, CP
    Bjarngard, BE
    Zhu, TC
    MEDICAL PHYSICS, 1996, 23 (04) : 505 - 511
  • [22] PERCENTAGE DEPTH DOSE FOR HIGH-ENERGY X-RAY BEAMS IN RADIOTHERAPY
    RAWLINSON, JA
    JOHNS, HE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1973, 118 (04) : 919 - 922
  • [23] Fabrication of high energy X-ray compound kinoform lenses using X-ray lithography
    Liu, Jing
    Zhang, Weiwei
    Chang, Guangcai
    Yi, Futing
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2017, 23 (05): : 1553 - 1562
  • [24] MATRIX DOSIMETER TO STUDY UNIFORMITY OF HIGH-ENERGY X-RAY BEAMS
    JOHNS, HE
    RAWLINSON, JA
    TAYLOR, WB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1974, 120 (01) : 192 - 201
  • [25] Fabrication of high energy X-ray compound kinoform lenses using X-ray lithography
    Jing Liu
    Weiwei Zhang
    Guangcai Chang
    Futing Yi
    Microsystem Technologies, 2017, 23 : 1553 - 1562
  • [26] Penumbra width correction of clinical high-energy X-ray beams
    Kazi, A
    Sahoo, N
    Hoffman, M
    MEDICAL PHYSICS, 2004, 31 (06) : 1908 - 1908
  • [27] Dosimetric application of a special pencil ionization chamber in radiotherapy X-ray beams
    Neves, Lucio P.
    Perini, Ana P.
    Fernandez-Varea, Jose M.
    Cassola, Vagner F.
    Kramer, Richard
    Khoury, Helen J.
    Caldas, Linda V. E.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 98 - 100
  • [28] Experimental determination of the dose kernel in high-energy x-ray beams
    Department of Radiation Oncology, Roger Williams Medical Center, Brown University, Providence, RI 02908-4735, United States
    不详
    MED. PHYS., 4 (505-511):
  • [29] DOSIMETRIC ASPECTS OF 4 MV X-RAY BEAMS FLATTENED WITH A URANIUM FILTER
    NAIR, R
    KARTHA, M
    MENON, NS
    BAUER, C
    BATLEY, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1977, 22 (03): : 567 - 567
  • [30] Dosimetric effects of brass mesh bolus on skin dose and dose at depth for postmastectomy chest wall irradiation
    Al-Rahbi, Zakiya S.
    Cutajar, Dean L.
    Metcalfe, Peter
    Rosenfeld, Anatoly B.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 54 : 84 - 93