Experimental study of source of background noise in muon radiography using emulsion film detectors

被引:24
|
作者
Nishiyama, R. [1 ]
Miyamoto, S. [1 ]
Naganawa, N. [2 ]
机构
[1] Univ Tokyo, Earthquake Res Inst, Tokyo 113, Japan
[2] Nagoya Univ, Dept Phys, Grad Sch Sci, Nagoya, Aichi 464, Japan
关键词
CLOUD CHAMBER; TEV; VOLCANOS; SPECTRA; SYSTEM; LEVEL;
D O I
10.5194/gi-3-29-2014
中图分类号
P [天文学、地球科学];
学科分类号
07 ;
摘要
The aim of this study is to ascertain and confirm the source of background noise in cosmic-ray muon radiography (muography) using emulsion film detectors. For this, we build two types of emulsion detectors with different momentum thresholds and perform test measurements of an actual geoscientific target. This experiment reveals that contamination of nonsignal particles with momenta of less than 2 GeV c(-1) cause significant systematic errors for the density estimation of muography. Utilizing the results of precedent studies, we conclude that the origin of these low-momentum particles is either electromagnetic components of air showers or cosmic-ray muons scattered in topographic material. In this paper, we analyze the emulsion data in detail, including the film-inefficiency compensation and momentum selection by applying an upper bound to the chi-square distribution for the data.
引用
收藏
页码:29 / 39
页数:11
相关论文
共 50 条
  • [41] An experimental study of reducing narrowband noise of a slat using chevrons
    M. Yu. Zaitsev
    I. V. Belyaev
    V. F. Kopiev
    M. A. Mironov
    Acoustical Physics, 2012, 58 : 411 - 419
  • [42] Experimental Study on Thickness Reduction of Noise Suppression Sheet by Attaching Periodic Metal Film
    Otsuka, Kyota
    Suzuki, Sho
    Kiyomi, Kota
    Tomizuka, Yusuke
    Ohno, Takanobu
    Tanii, Kosei
    2014 ASIA-PACIFIC MICROWAVE CONFERENCE (APMC), 2014, : 396 - 398
  • [43] Experimental and analytical study of a loop heat pipe at a positive elevation using neutron radiography
    Chuang, Po-Ya Abel
    Cimbala, John M.
    Brenizer, Jack S.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 77 : 84 - 95
  • [44] An experimental study on using a diagnostic computed radiography system as a quality assurance tool in radiotherapy
    T. Peace
    B. Subramanian
    P. Ravindran
    Australasian Physics & Engineering Sciences in Medicine, 2008, 31 : 226 - 234
  • [45] An experimental study on using a diagnostic computed radiography system as a quality assurance tool in radiotherapy
    Peace, T.
    Subramanian, B.
    Ravindran, P.
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2008, 31 (03) : 226 - 234
  • [46] SIGNAL TO NOISE ENHANCEMENT AND ELIMINATION OF BACKGROUND SIGNAL USING PHASE LOCKED SOURCE MODULATION TECHNIQUES WITH MICHELSON INTERFEROMETERS
    DURANA, JF
    MANTZ, AW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 32 - 32
  • [47] Preliminary experimental study of a positioning system using multiple radiation spectroscopy detectors
    Seung-Jae Lee
    Cheol-Ha Baek
    Journal of the Korean Physical Society, 2021, 79 : 168 - 172
  • [48] Preliminary experimental study of a positioning system using multiple radiation spectroscopy detectors
    Lee, Seung-Jae
    Baek, Cheol-Ha
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2021, 79 (02) : 168 - 172
  • [49] Study of excess noise in MWIR photovoltaic detectors fabricated using a new junction formation technology
    Rais, MH
    Musca, CA
    Dell, JM
    Antoszewski, J
    Nener, BD
    Faraone, L
    DEVICE AND PROCESS TECHNOLOGIES FOR MEMS AND MICROELECTRONICS, 1999, 3892 : 221 - 232
  • [50] Low-Noise Low-Mass Front End Electronics for Low-Background Physics Experiments Using Germanium Detectors
    Barton, Paul
    Luke, Paul
    Amman, Mark
    Chan, Yuen-Dat
    Detwiler, Jason
    Loach, James
    Martin, Ryan
    Poon, Alan
    Tindall, Craig
    Vetter, Kai
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1976 - 1979