Direct driven doubly salient electrical wind generator with exterior rotor

被引:0
|
作者
Wei, Jiadan [1 ]
Zhou, Bo [1 ]
Zhang, Yongshuai [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Key Lab Aeronaut Power Syst Ctr, Nanjing, Peoples R China
关键词
DSEG; DDWP; control strategy; DDDSEWG; finite element analysis;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The doubly salient electrical generator (DSEG) has characteristics of easy control and high reliability, so it has been used in the high speed field. To satisfy the low speed and high power characteristics of direct driven wind power (DDWP), this paper first analyzes the control strategy of DSEG used in DDWP, and then studies the novel direct driven doubly salient electrical wind generator (DDDSEWG) with exterior rotor by the finite element analysis in Ansoft. The DDDSEWG is fitted for the area of wide speed and load range. Simulation results by Matlab demonstrate the positive electrical characteristics of DDDSEWG.
引用
收藏
页码:54 / 59
页数:6
相关论文
共 50 条
  • [41] Rotor power control in doubly fed induction generator wind turbine under grid faults
    Hachicha, Fatma
    Krichen, Lotfi
    ENERGY, 2012, 44 (01) : 853 - 861
  • [42] Modelling and analysis of direct-driven permanent magnet synchronous generator wind turbine based on wind-rotor neural network model
    Dai, J-C
    Hu, Y-P
    Liu, D-S
    Wei, J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2012, 226 (A1) : 62 - 72
  • [43] Research of 0-70 Volts DC Electrical Source Based on Doubly Salient Generator and DSP
    Han Guyong
    Wang Baocheng
    Wang Fengjun
    2010 INTERNATIONAL CONFERENCE ON INFORMATION, ELECTRONIC AND COMPUTER SCIENCE, VOLS 1-3, 2010, : 1190 - +
  • [44] Wind turbine system with Doubly-Fed Induction Generator and rotor power feedback control
    Faculty of Electrical Engineering Mechanical Engineering and Naval Architecture, University in Split, Rudjera Boskovica bb, 21000 Split, Croatia
    WSEAS Trans. Syst., 2006, 12 (2860-2867):
  • [45] A new PD( 1+PI) direct power controller for the variable-speed multi-rotor wind power system driven doubly-fed asynchronous generator
    Benbouhenni, Habib
    Bounadja, Elhadj
    Gasmi, Hamza
    Bizon, Nicu
    Colak, Ilhami
    ENERGY REPORTS, 2022, 8 : 15584 - 15594
  • [46] A new PD(1+PI) direct power controller for the variable-speed multi-rotor wind power system driven doubly-fed asynchronous generator
    Benbouhenni, Habib
    Bounadja, Elhadj
    Gasmi, Hamza
    Bizon, Nicu
    Colak, Ilhami
    Energy Reports, 2022, 8 : 15584 - 15594
  • [47] Improved Direct Power Control of a Wind Turbine Driven Doubly Fed Induction Generator During Transient Grid Voltage Unbalance
    Nian, Heng
    Song, Yipeng
    Zhou, Peng
    He, Yikang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (03) : 976 - 986
  • [48] Electrical & mechanical diagnostic indicators of wind turbine induction generator rotor faults
    Zappala, D.
    Sarma, N.
    Djurovic, S.
    Crabtree, C. J.
    Mohammad, A.
    Tavner, P. J.
    RENEWABLE ENERGY, 2019, 131 : 14 - 24
  • [49] Design Optimization of Outer Rotor Toothed Doubly Salient Permanent Magnet Generator Using Symbiotic Organisms Search Algorithm
    Guerroudj, Cherif
    Karnavas, Yannis L.
    Charpentier, Jean-Frederic
    Chasiotis, Ioannis D.
    Bekhouche, Lemnouer
    Saou, Rachid
    Zaim, Mohammed El-Hadi
    ENERGIES, 2021, 14 (08)
  • [50] Study on dynamic equivalence model of wind farms with wind turbine driven doubly fed induction generator
    Mi, Zengqiang
    Su, Xunwen
    Yu, Yang
    Wang, Yi
    Wu, Tao
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (17): : 72 - 77