Flow and Containment Characteristics of an Air-curtain Fume Hood Operated at High Temperatures

被引:5
|
作者
Chen, Jia-Kun [2 ]
Huang, Rong Fung [1 ]
Hsin, Pei-Yi [1 ]
Hsu, Ching Min [2 ]
Chen, Chun-Wann [3 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei, Taiwan
[2] Natl Taiwan Univ Sci & Technol, Grad Inst Appl Sci & Technol, Taipei, Taiwan
[3] Council Labor Affairs, Inst Occupat Safety & Hlth, Shijr City, Taipei County, Taiwan
关键词
Air-curtain fume hood; Flow visualization; Tracer-gas test; High temperature operation; AIRBORNE NANOPARTICLE EXPOSURES; PERFORMANCE; CUPBOARDS;
D O I
10.2486/indhealth.MS1326
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The flow and leakage characteristics of the air-curtain fume hood under high temperature operation (between 100 degrees C and 250 degrees C) were studied. Laser-assisted flow visualization technique was used to reveal the hot plume movements in the cabinet and the critical conditions for the hood-top leakage. The sulfur hexafluoride tracer-gas concentration test method was employed to examine the containment spillages from the sash opening and the hood top. It was found that the primary parameters dominating the behavior of the flow field and hood performance are the sash height and the suction velocity as an air-curtain hood is operated at high temperatures. At large sash height and low suction velocity, the air curtain broke down and accompanied with three-dimensional flow in the cabinet. Since the suction velocity was low and the sash opening was large, the makeup air drawn down from the hood top became insufficient to counter act the rising hot plume. Under this situation, containment leakage from the sash opening and the hood top was observed. At small sash opening and high suction velocity, the air curtain presented robust characteristics and the makeup air flow from the hood top was sufficiently large. Therefore the containment leakages from the sash opening and the hood top were not observed. According to the results of experiments, quantitative operation sash height and suction velocity corresponding to the operation temperatures were suggested.
引用
收藏
页码:103 / 114
页数:12
相关论文
共 50 条
  • [1] Dynamic Effects on Containment of Air-Curtain Fume Hood Operated with Heat Source
    Chen, Jia-Kun
    Huang, Rong Fung
    Hsin, Pei-Yi
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2012, 9 (11) : 640 - 652
  • [2] Influence of high heat load on flow and containment of an inclined air-curtain (IAC) fume hood
    Huang, Rong Fung
    Hsu, Ching Min
    Lin, Kai Ling
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2018, 15 (04) : 322 - 333
  • [3] Flow and Containment Characteristics of a Sash-less, Variable-Height Inclined Air-Curtain Fume Hood
    Huang, Rong Fung
    Chen, Jia-Kun
    Hung, Wei-Lun
    ANNALS OF OCCUPATIONAL HYGIENE, 2013, 57 (07): : 934 - 952
  • [4] Flow characteristics of an inclined air-curtain range hood in a draft
    Chen, Jia-Kun
    INDUSTRIAL HEALTH, 2015, 53 (04) : 346 - 353
  • [5] Development and Characterization of an Inclined Air-Curtain (IAC) Fume Hood
    Huang, Rong Fung
    Chen, Jia-Kun
    Tang, Kun-Chi
    ANNALS OF OCCUPATIONAL HYGIENE, 2015, 59 (05): : 655 - 667
  • [6] AN AIR-CURTAIN FUME CABINET
    ETKIN, B
    MCKINNEY, WD
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1992, 53 (10): : 625 - 631
  • [7] Flow and Leakage Characteristics of a Sashless Inclined Air-Curtain (sIAC) Fume Hood Containing Tall Pollutant-Generation Tanks
    Chen, Jia-Kun
    Huang, Rong Fung
    Hung, Wei-Lun
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2013, 10 (12) : 694 - 704
  • [8] Installation of a flow control device in an inclined air-curtain fume hood to control wake-induced exposure
    Chen, Jia-Kun
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2016, 13 (08) : 588 - 597
  • [9] Static Condition Differences in Conventional and Inclined Air-Curtain Range Hood Flow and Spillage Characteristics
    Huang, Rong Fung
    Nian, You-Cyun
    Chen, Jia-Kun
    ENVIRONMENTAL ENGINEERING SCIENCE, 2010, 27 (06) : 513 - 522
  • [10] Development and evaluation of an air-curtain fume cabinet with considerations of its aerodynamics
    Huang, R. F.
    Wu, Y. D.
    Chen, H. D.
    Chen, C. -C.
    Chen, C. -W.
    Chang, C. -P.
    Shih, T. -S.
    ANNALS OF OCCUPATIONAL HYGIENE, 2007, 51 (02): : 189 - 206