Intratracheal pressure monitoring during synchronized intermittent mandatory ventilation and pressure controlled inverse ratio ventilation

被引:8
|
作者
Warters, RD
Allen, SJ
Tonnesen, AS
机构
[1] Department of Anesthesiology, University of Texas Medical School, Houston, TX
[2] Department of Anesthesiology, University of Texas Medical School, MSB 5.020, Houston, TX 77030
关键词
airway pressure; alveolar pressure; airway resistance; monitoring techniques; peak inspiratory pressure; positive end expiratory pressure; mean airway pressure; intermittent mandatory ventilation; pressure controlled-inverse ratio ventilation;
D O I
10.1097/00003246-199702000-00005
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: To directly measure airway pressures proximal and distal to endotracheal tubes during conventional synchronized intermittent mandatory ventilation (SIMV) and pressure con trolled-inverse ratio Ventilation (PC IRV), and to compare them with these values measured by the ventilator. Design: Prospective, nonrandomized study. Setting: Surgical intensive care unit at a trauma center. Patients: Group 1: Eight intubated adult patients connected to mechanical ventilators in the SIMV mode were studied. All patients required mechanical Ventilation following traumatic injuries. Group 2: Five intubated adult patients with adult respiratory distress syndrome connected to mechanical ventilators were studied. Interventions: A small polyethylene catheter was threaded through each endotracheal tube such that it could be positioned to measure pressures proximal and distal to the tubes. Measurements and Main Results: During SIMV, a significant pressure gradient exists across endotracheal tubes. In addition, although initiation of PC-IRV did lead to a lower peak airway pressure measured proximally, intratracheal peak airway pressure was unchanged. Conclusions: A pressure gradient exists during inspiration from the ventilator to the trachea in mechanically ventilated patients. Tracheal pressures cannot be predicted from proximal airway pressure monitors because of marked variation in endotra cheal tube resistance in vivo. Initiation of PC-IRV does not result in a decrease in peak airway pressure when measured intratracheally.
引用
收藏
页码:227 / 230
页数:4
相关论文
共 50 条
  • [41] INSPIRATORY WORK OF BREATHING DURING SYNCHRONIZED INTERMITTENT MANDATORY VENTILATION (SIMV)
    MARINI, JJ
    SMITH, TC
    RODRIGUEZ, RM
    LAMB, VJ
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1986, 133 (04): : A120 - A120
  • [42] The Comparison of Synchronized Intermittent Mandatory Ventilation with Nonsynchronised Intermittent Mandatory Ventilation in Newborn with Respiratory Failure and Transient Tachypnea
    Cosar, Hese
    Bulut, Yasin
    Yilmaz, Ozgur
    Temur, Muzaffer
    JOURNAL OF PEDIATRIC RESEARCH, 2016, 3 (03) : 154 - 158
  • [43] Respiratory monitoring during pressure controlled ventilation (PCV)
    Volta, CA
    Alvisi, V
    Marangoni, E
    Bertacchini, S
    Romanello, A
    Ragazzi, R
    Verri, M
    Alvisi, R
    INTENSIVE CARE MEDICINE, 2003, 29 : S85 - S85
  • [44] Pressure-controlled inverse ratio ventilation after cardiac surgery
    Smith, RPR
    Fletcher, R
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2001, 18 (06) : 401 - 406
  • [45] Pressure-regulated volume control ventilation vs synchronized intermittent mandatory ventilation for very low-birth-weight infants - A randomized controlled trial
    D'Angio, CT
    Chess, PR
    Kovacs, SJ
    Sinkin, RA
    Phelps, DL
    Kendig, JW
    Myers, GJ
    Reubens, L
    Ryan, RM
    ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 2005, 159 (09): : 868 - 875
  • [46] Randomized, controlled trial comparing pressure support (PS) plus synchronized intermittent mandatory ventilation (SIMV) with SIMV in preterm infants
    Reyes, Z
    Tauscher, M
    Claure, N
    D'Ugard, C
    Bancalari, E
    PEDIATRIC RESEARCH, 2004, 55 (04) : 466A - 466A
  • [47] Comparison of synchronized and conventional intermittent mandatory ventilation in neonates
    Chen, JY
    Ling, UP
    Chen, JH
    ACTA PAEDIATRICA JAPONICA, 1997, 39 (05): : 578 - 583
  • [48] Outcomes of Patients Ventilated With Synchronized Intermittent Mandatory Ventilation With Pressure Support A Comparative Propensity Score Study
    Ortiz, Guillermo
    Frutos-Vivar, Fernando
    Ferguson, Niall D.
    Esteban, Andres
    Raymondos, Konstantinos
    Apezteguia, Carlos
    Hurtado, Javier
    Gonzalez, Marco
    Tomicic, Vinko
    Elizalde, Jose
    Abroug, Fekri
    Arabi, Yaseen
    Pelosi, Paolo
    Anzueto, Antonio
    CHEST, 2010, 137 (06) : 1265 - 1277
  • [49] Synchronized intermittent mandatory ventilation with volume guarantee and pressure support in neonates: Detailed analysis of ventilator parameters
    Balajthy, Andras
    Balazs, Gergely
    Kovacs, Tamas
    Belteki, Gusztav
    PEDIATRIC PULMONOLOGY, 2023, 58 (06) : 1703 - 1710
  • [50] Mechanical Ventilation During Cardiopulmonary Resuscitation With Intermittent Positive-Pressure Ventilation, Bilevel Ventilation, or Chest Compression Synchronized Ventilation in a Pig Model
    Kill, Clemens
    Hahn, Oliver
    Dietz, Florian
    Neuhaus, Christian
    Schwarz, Stefan
    Mahling, Robert
    Wallot, Pascal
    Jerrentrup, Andreas
    Steinfeldt, Thorsten
    Wulf, Hinnerk
    Dersch, Wolfgang
    CRITICAL CARE MEDICINE, 2014, 42 (02) : E89 - E95