Adaptive Control Algorithm for DSTATCOM in three phase four wire distribution systems for Power Quality Improvement

被引:0
|
作者
Ram, Atma [1 ]
Sharma, Paras Ram [1 ]
Ahuja, Rajesh Kr [1 ]
机构
[1] YMCA Univ Sci & Tech, Dept Elect Engn, Faridabad, India
关键词
Nonlinear load; four leg VSC; Power quality; neutral current compensation; INJECTION;
D O I
10.1109/rdcape47089.2019.8979019
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
this adaptive control technique has been developed for four-leg VSC based DSTATCOM using MATLAB Simulink environment and implemented in three phase four wire distribution systems. In this technique three reference currents are estimated from fundamental active power component of three distorted load currents. The performance of DSTATCOM found satisfactory in terms of load balancing, power factor improvement, source current harmonic elimination, and selfregulated DC bus voltage using adaptive control technique under steady state and dynamic condition using nonlinear load.
引用
收藏
页码:622 / 627
页数:6
相关论文
共 50 条
  • [41] DSTATCOM with Reduced Switches Using Two-Leg VSC and a Zig-Zag Transformer for Power Quality Improvement in Three-Phase Four-Wire Distribution System
    Singh, Bhim
    Jayaprakash, P.
    Somayajulu, T. R.
    Kothari, D. P.
    2008 IEEE REGION 10 CONFERENCE: TENCON 2008, VOLS 1-4, 2008, : 97 - +
  • [42] Simple algorithm for current and voltage control of LCL DSTATCOM for power quality improvement
    Myneni, Hareesh
    Kumar, Ganjikunta Siva
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (03) : 423 - 434
  • [43] Back-Propagation Control Algorithm for Power Quality Improvement Using DSTATCOM
    Singh, Bhim
    Arya, Sabha Raj
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (03) : 1204 - 1212
  • [44] Performance Analysis of DSTATCOM for Three Phase Three Wire Distribution System
    Aseem, K.
    Vanitha, V.
    Kumar, Selva S.
    INTERNATIONAL ENERGY JOURNAL, 2020, 20 : 271 - 278
  • [45] Performance analysis of DSTATCOM for three phase three wire distribution system
    Aseem, K.
    Vanitha, V.
    Selva Kumar, S.
    Aseem, K. (azieee@gmail.com), 1600, Regional Energy Resources Information Center (RERIC), Asian Institute of Technology (20): : 271 - 277
  • [46] Adaptive Interval Type II Fuzzy Logic Controller with Interface Inductor Bank Pulse Generator Based Three-Phase Four-Wire DSTATCOM Device for Power Quality Improvement
    Alsebai M.D.
    Narayanan K.
    Pedapenki K.K.
    Periodica polytechnica Electrical engineering and computer science, 2023, 67 (02): : 113 - 135
  • [47] Three-phase four switch DSTATCOM topologies with special transformers for neutral current compensation and power quality improvement
    Kumar, Alladi Pranay
    Kumar, Ganjikunta Siva
    Sreenivasarao, Dharmavarapu
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (03) : 368 - 379
  • [48] A Versatile Unified Power Quality Conditioner Applied to Three-Phase Four-Wire Distribution Systems Using a Dual Control Strategy
    Modesto, Rodrigo Augusto
    Oliveira da Silva, Sergio Augusto
    de Oliveira, Azauri Albano
    Bacon, Vinicius Dario
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (08) : 5503 - 5514
  • [49] Mitigation of Voltage Unbalance by DSTATCOM in a Three Phase Four Wire System
    Patel, Dhairya
    Venkatraman, K.
    Rudraraju, Venkata Rama Raju
    JOURNAL OF POWER TECHNOLOGIES, 2019, 99 (04): : 237 - 244
  • [50] Hybrid 3P4W DSTATCOM for Three Phase Four Wire Distribution System
    Suresh, Dhanavath
    Rao, Dharavath Mohan
    Sukumar, G. Durga
    PROCEEDINGS OF THE FIRST IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, INTELLIGENT CONTROL AND ENERGY SYSTEMS (ICPEICES 2016), 2016,