Surface plasmon resonance sensor for heparin measurements in blood plasma

被引:58
|
作者
Gaus, K [1 ]
Hall, EAH [1 ]
机构
[1] Univ Cambridge, Inst Biotechnol, Cambridge CB2 1QT, England
来源
BIOSENSORS & BIOELECTRONICS | 1998年 / 13卷 / 12期
关键词
anticoagulant; polyethylene imine (PEI); protamine;
D O I
10.1016/S0956-5663(98)00094-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Surface plasmon resonance (SPR) was used as an affinity biosensor to determine absolute heparin concentrations in human blood plasma samples. Protamine and polyethylene imine (PEI) were evaluated as heparin affinity surfaces. Heparin adsorption onto protamine in blood plasma was specific with a lowest detection limit of 0.2 U/ml and a linear window of 0.2-2 U/ml. Although heparin adsorption onto PEI in buffer solution had indicated superior sensitivity to that on protamine, in blood plasma it was not specific for heparin and adsorbed plasma species to a steady-state equilibrium. By reducing the incubation time and diluting the plasma samples with buffer to 50%, the non-specific adsorption of plasma could be controlled and a PEI pre-treated with blood plasma could be used successfully for heparin determination. Heparin adsorption in 50% plasma was linear between 0.05 and 1 U/ml so that heparin plasma levels of 0.1-2 U/ml could be determined within a relative error of 11% and an accuracy of 0.05 U/ml. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:1307 / 1315
页数:9
相关论文
共 50 条
  • [31] Evaluating Heparin Products for Heparin-Induced Thrombocytopenia Using Surface Plasmon Resonance
    Zhang, Fuming
    Datta, Payel
    Dordick, Jonathan S.
    Linhardt, Robert J.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2020, 109 (02) : 975 - 980
  • [32] Measurements of refractive index change due to positive ions using a surface plasmon resonance sensor
    Ko, Hyungduk
    Kameoka, Jun
    Su, Chin B.
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 143 (01) : 381 - 386
  • [33] Surface plasmon resonance biosensor for parallelized detection of protein biomarkers in diluted blood plasma
    Piliarik, Marek
    Bockova, Marketa
    Homola, Jiri
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1656 - 1661
  • [34] A Portable Surface Plasmon Resonance Sensor for a Diagnostic Tool
    Sohn, Young-Soo
    SENSOR LETTERS, 2011, 9 (01) : 272 - 275
  • [35] Characterisation of gold surface plasmon resonance sensor substrates
    Sexton, B. A.
    Feltis, B. N.
    Davis, T. J.
    SENSORS AND ACTUATORS A-PHYSICAL, 2008, 141 (02) : 471 - 475
  • [36] Miniaturization of fiber optic surface plasmon resonance sensor
    Acad of Sciences of the Czech, Republic, Prague, Czech Republic
    Sens Actuators, B Chem, 1-3 (311-315):
  • [37] DESIGN OF LOW COST SURFACE PLASMON RESONANCE SENSOR
    Kusko, Mihai
    2012 INTERNATIONAL SEMICONDUCTOR CONFERENCE (CAS), VOLS 1 AND 2, 2012, 2 : 251 - 254
  • [38] Encoded and multiplexed surface plasmon resonance sensor platform
    Kastl, Katja F.
    Lowe, Christopher R.
    Norman, Carl E.
    ANALYTICAL CHEMISTRY, 2008, 80 (20) : 7862 - 7869
  • [39] A surface plasmon resonance based integrated optical sensor
    Homola, J
    Ctyroky, J
    Skalsky, M
    Hradilova, J
    Kolarova, P
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 39 (1-3) : 286 - 290
  • [40] Surface Plasmon Resonance Biosensors: Sensor Response Modeling
    Caglayan, Mustafa Oguzhan
    Atar, Necip
    Ustundag, Zafer
    JOURNAL OF COMPUTATIONAL AND THEORETICAL NANOSCIENCE, 2013, 10 (05) : 1248 - 1251