Non-invasive assessment of human baroreflex during different body positions

被引:22
|
作者
Iida, R
Hirayanagi, K
Iwasaki, K
Ogawa, S
Suzuki, H
Yajima, K
机构
[1] Surugadai Nihon Univ Hosp, Dept Anesthesiol, Chiyoda Ku, Tokyo 1018309, Japan
[2] Nihon Univ, Sch Med, Dept Hyg, Itabashi Ku, Tokyo 1738610, Japan
来源
关键词
baroreceptor reflex; body position; spectral analysis;
D O I
10.1016/S0165-1838(98)00188-X
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Two techniques for evaluating human baroreflex sensitivity (BRS), i.e. the sequence technique and the cross-spectral technique, were compared during the following four different body positions: 6 degrees head-down tilt (HDT), supine (Sup). 60 degrees head-up tilt (HUT) and upright (Upr). The sequence technique is based on the slope of linear regression between beat-to-beat RR intervals and systolic blood pressures. The cross-spectral technique is based on the cross-spectral analysis of RR interval and systolic blood pressure variabilities, and the estimates of BRS were computed separately for die low-frequency region (0.04-0.15 Hz) and the high-frequency region (0.15-0.5 Hz), The BRS obtained by the sequence technique had a significant correlation to that obtained by the cross-spectral technique for the low-frequency region in HDT, Sup and HUT, but not in Upr. There was a significant correlation between the BRS obtained by the sequence technique and that obtained by the cross-spectral technique for the high-frequency region in every body position. It became clear that the sequence technique is mutually related to the cross-spectral technique for the high-frequency region, but not necessarily identical to the cross-spectral technique for the low-frequency region. Moreover, a comparison was also made between the baroreceptor activating sequence and the deactivating sequence in the sequence technique during the four different body positions. Although the estimates of BRS of the activating sequence and the deactivating sequence were similar in every body position, the numbers of their sequences were progressively separated in the order of HDT, Sup, HUT and Upr. The numbers of the activating sequence and the deactivating sequence in the sequence technique were found to be separated in a sympathetically dominant condition. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 50 条
  • [41] NON-INVASIVE ASSESSMENT OF HEART IN HYPERTENSIVE
    WIKSTRAND, J
    BERGLUND, G
    WILHELMSEN, L
    WALLENTIN, I
    OROURKE
    BAUER
    DUSTAN
    HUNYOR
    VARNAUSKAS
    ASTROM
    BROD
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1976, 6 : 1 - 7
  • [42] Non-invasive assessment of endothelial function
    Mullen, MJ
    Thorne, SA
    Deanfield, JE
    Jones, CJH
    HEART, 1997, 77 (04) : 297 - 298
  • [43] The non-invasive assessment of hepatic fibrosis
    Gheorghe, Gina
    Bungau, Simona
    Ceobanu, Gabriela
    Ilie, Madalina
    Bacalbasa, Nicolae
    Bratu, Ovidiu Gabriel
    Vesa, Cosmin Mihai
    Gaman, Mihnea-Alexandru
    Diaconu, Camelia Cristina
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2021, 120 (02) : 794 - 803
  • [44] Non-invasive assessment of coronary calcification
    Vliegenthart, R
    EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2004, 19 (12) : 1063 - 1072
  • [45] Non-invasive assessment of MASH resolution
    Dufour, Jean-Francois
    Wong, Vincent Wai-Sun
    GUT, 2024, 73 (08) : 1227 - 1228
  • [46] Non-invasive Assessment of Liver Fibrosis
    Joseph Redman
    Richard K. Sterling
    Current Treatment Options in Gastroenterology, 2020, 18 (2) : 255 - 269
  • [47] NON-INVASIVE ASSESSMENT OF THE VENTRICULAR-FUNCTION DURING ACUTE HIPOXEMIA
    CURIEL, R
    OSTOJIC, K
    CONDADO, J
    GOMEZ, J
    OCTAVIO, J
    ACTA CIENTIFICA VENEZOLANA, 1980, 31 (03): : 281 - 286
  • [48] An instrument for the non-invasive objective assessment of velar function during speech
    McLean, CC
    Kelly, SW
    Christopher, M
    Manley, G
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (01) : 7 - 14
  • [49] Toward Non-Invasive Pressure Assessment
    Bijnens, Nathalie
    Beulen, Bart
    Brands, Peter
    Rutten, Marcel
    van de Vosse, Frans
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, 2010, 2010, : 215 - 216
  • [50] Non-invasive intracranial pressure assessment
    Padayachy, Llewellyn C.
    CHILDS NERVOUS SYSTEM, 2016, 32 (09) : 1587 - 1597