Non-invasive assessment of human baroreflex during different body positions

被引:22
|
作者
Iida, R
Hirayanagi, K
Iwasaki, K
Ogawa, S
Suzuki, H
Yajima, K
机构
[1] Surugadai Nihon Univ Hosp, Dept Anesthesiol, Chiyoda Ku, Tokyo 1018309, Japan
[2] Nihon Univ, Sch Med, Dept Hyg, Itabashi Ku, Tokyo 1738610, Japan
来源
关键词
baroreceptor reflex; body position; spectral analysis;
D O I
10.1016/S0165-1838(98)00188-X
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Two techniques for evaluating human baroreflex sensitivity (BRS), i.e. the sequence technique and the cross-spectral technique, were compared during the following four different body positions: 6 degrees head-down tilt (HDT), supine (Sup). 60 degrees head-up tilt (HUT) and upright (Upr). The sequence technique is based on the slope of linear regression between beat-to-beat RR intervals and systolic blood pressures. The cross-spectral technique is based on the cross-spectral analysis of RR interval and systolic blood pressure variabilities, and the estimates of BRS were computed separately for die low-frequency region (0.04-0.15 Hz) and the high-frequency region (0.15-0.5 Hz), The BRS obtained by the sequence technique had a significant correlation to that obtained by the cross-spectral technique for the low-frequency region in HDT, Sup and HUT, but not in Upr. There was a significant correlation between the BRS obtained by the sequence technique and that obtained by the cross-spectral technique for the high-frequency region in every body position. It became clear that the sequence technique is mutually related to the cross-spectral technique for the high-frequency region, but not necessarily identical to the cross-spectral technique for the low-frequency region. Moreover, a comparison was also made between the baroreceptor activating sequence and the deactivating sequence in the sequence technique during the four different body positions. Although the estimates of BRS of the activating sequence and the deactivating sequence were similar in every body position, the numbers of their sequences were progressively separated in the order of HDT, Sup, HUT and Upr. The numbers of the activating sequence and the deactivating sequence in the sequence technique were found to be separated in a sympathetically dominant condition. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:164 / 170
页数:7
相关论文
共 50 条
  • [1] Non-invasive assessment of the vascular baroreflex arm
    Javorka, M.
    Krohova, J.
    Czippelova, B.
    Turianikova, Z.
    Mazgutova, N.
    Wiszt, R.
    Lazarova, Z.
    Faes, L.
    ACTA PHYSIOLOGICA, 2019, 227 : 60 - 60
  • [2] Simple non-invasive assessment of the mechanical baroreflex gain
    Lenard, Z
    Studinger, P
    Mersich, B
    Kocsis, L
    FASEB JOURNAL, 2003, 17 (04): : A111 - A111
  • [3] Non-invasive approach for the assessment of sympathetic baroreflex function: A feasibility study
    Paleczny, Bartlomiej
    Siennicka, Agnieszka
    Ponikowski, Piotr
    Ponikowska, Beata
    AUTONOMIC NEUROSCIENCE-BASIC & CLINICAL, 2017, 203 : 108 - 112
  • [4] NON-INVASIVE METHODS FOR ASSESSMENT OF BODY-COMPOSITION
    FOSTER, MA
    FOWLER, PA
    FULLER, MF
    KNIGHT, CH
    PROCEEDINGS OF THE NUTRITION SOCIETY, 1988, 47 (03) : 375 - &
  • [5] Are baroreflex events detected by invasive and non-invasive techniques coincident?
    Smith, Stephen M.
    Potter, John F.
    Samani, Nilesh J.
    Sammons, Emily L.
    Rathbone, Wendy E.
    Bentley, Stephen
    Panerai, Ronney B.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2008, 28 (04) : 262 - 269
  • [6] Non-invasive measurement of iron overload in the human body
    Marinelli, Mauro
    Cuneo, Stefano
    Gianesin, Barbara
    Lavagetto, Antonella
    Lamagna, Martina
    Oliveri, Eraldo
    Sobrero, Giuliano
    Terenzani, Laura
    Forni, Gian Luca
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2006, 16 (02) : 1513 - 1518
  • [7] Variations in Non-invasive Radial Artery Pulse Waveform at Different Measuring Positions
    Lee, Jeon
    Jeon, Young-Ju
    Lee, Hae-Jung
    Kim, Jong-Yeol
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 1415 - +
  • [8] Non-invasive assessment of baroreflex sensitivity and relation to measures of heart rate variability in man
    Pellizzer, AM
    Kamen, PW
    Jackman, G
    Brazzale, D
    Krum, H
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 1996, 23 (6-7) : 621 - 624
  • [9] Baroreflex function assesstment by a non-invasive pressor test
    Duarte, M.
    Grana, D. R.
    Bellido, C. A.
    Milei, J.
    CIRCULATION, 2008, 118 (12) : E242 - E242
  • [10] Assesstment of baroreflex function by a non-invasive pressor test
    Duarte, M.
    Grana, D. R.
    Bellido, C. A.
    Milei, J.
    JOURNAL OF HYPERTENSION, 2008, 26 : S408 - S408