PHOTO-INDUCED FLOW-INJECTION DETERMINATION OF NITRATE IN WATER

被引:0
|
作者
Mikuska, Pavel [1 ]
Capka, Lukas [1 ]
Vecera, Zbynek [1 ]
Kalinichenko, Ivan [2 ]
Kellner, Josef [3 ]
机构
[1] Acad Sci Czech Republ, Inst Analyt Chem, Brno, Czech Republic
[2] Natl Acad Sci Ukraine, AV Dumansky Inst Colloid & Water Chem, Kiev, Ukraine
[3] Univ Def, Brno, Czech Republic
关键词
NITRITE;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 mu m, o.d. 720 mu m). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 x 10(-10) M (S/N = 3). Linear range of the method is 2 x 10(-9) to 1 x 10(-5) M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column. FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method.
引用
收藏
页码:151 / 154
页数:4
相关论文
共 50 条
  • [31] A green analytical procedure for flow-injection determination of nitrate in natural waters
    Melchert, WR
    Rocha, FRP
    TALANTA, 2005, 65 (02) : 461 - 465
  • [32] FLOW-INJECTION DETERMINATION OF NITRATE IN VEGETABLES USING A TUBULAR POTENTIOMETRIC DETECTOR
    LIMA, JLFC
    RANGEL, AOSS
    SOUTO, MRS
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1995, 43 (03) : 704 - 707
  • [33] SPECTROPHOTOMETRIC OR COULOMETRIC DETERMINATION OF NITRATE WITH AN ELECTROCHEMICAL REDUCTOR USING FLOW-INJECTION
    NAKATA, R
    TERASHITA, M
    NITTA, A
    ISHIKAWA, K
    ANALYST, 1990, 115 (04) : 425 - 430
  • [34] SEQUENTIAL DETERMINATION OF CALCIUM AND NITRATE IONS IN WATERS BY POTENTIOMETRIC FLOW-INJECTION
    ALONSOCHAMARRO, J
    BARTROLI, J
    JUN, S
    LIMA, JLFC
    CONCEICAO, M
    MONTENEGRO, BSM
    ANALYST, 1993, 118 (12) : 1527 - 1532
  • [35] Report on interlaboratory testing for the determination of nitrite and nitrate in river-water samples by flow-injection analysis
    Higuchi, K
    Goto, R
    Kawashima, T
    Oguma, K
    Kawase, A
    Ogura, H
    BUNSEKI KAGAKU, 2000, 49 (01) : 35 - 42
  • [36] Chemiluminometric photo-induced determination of Strychnine in a Multicommutation flow assembly
    Alves Ferreira, A. S.
    Albert-Garcia, J. R.
    Martinez Calatayud, J.
    TALANTA, 2007, 72 (03) : 1223 - 1229
  • [37] Photo-induced chemiluminometric determination of acrolein in a multicommutation flow assembly
    Gamazo Climent, T.
    Albert-Garcia, J. R.
    Martinez Calatayud, J.
    ANALYTICAL LETTERS, 2007, 40 (04) : 629 - 643
  • [38] Determination of nitrate and nitrite in freshwaters using flow-injection with luminol chemiluminescence detection
    Yaqoob, Mohammad
    Biot, Beatriz Folgado
    Nabi, Abdul
    Worsfold, Paul J.
    LUMINESCENCE, 2012, 27 (05) : 419 - 425
  • [39] DETERMINATION OF SULFATE IN NATURAL-WATER BY FLOW-INJECTION ANALYSIS
    NAKASHIMA, S
    YAGI, M
    ZENKI, M
    DOI, M
    TOEI, K
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1984, 317 (01): : 29 - 31
  • [40] DETERMINATION OF CYANIDE IN WASTE-WATER BY FLOW-INJECTION ANALYSIS
    SCHONDORF, G
    ENGELHARDT, H
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 333 (07): : 719 - 720