Serum amyloid A does not affect high-density lipoprotein cholesterol measurement by a homogeneous assay

被引:3
|
作者
Sato, Megumi [1 ,2 ]
Ohkawa, Ryunosuke [1 ]
Low, Hann [3 ]
Nishimori, Madoka [2 ]
Okubo, Shigeo [4 ]
Yoshimoto, Akira [1 ,2 ]
Yano, Kouji [5 ]
Kameda, Takahiro [6 ]
Yatomi, Yutaka [2 ]
Tozuka, Minoru [1 ]
机构
[1] TMDU, Grad Sch Med & Dent Sci, Dept Analyt Lab Chem, Bunkyo Ku, 1-5-45 Yushima, Tokyo 1138510, Japan
[2] Univ Tokyo Hosp, Dept Clin Lab, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138655, Japan
[3] Baker Heart & Diabet Inst, Dept Lipoprot & Atherosclerosis, 75 Commercial Rd, Melbourne, Vic 3004, Australia
[4] Bunkyo Gakuin Univ, Fac Hlth Sci Technol, Bunkyo Ku, 1-19-1 Mukogaoka, Tokyo 1138668, Japan
[5] Juntendo Univ, Ctr Genom & Regenerat Med, Grad Sch Med, Bunkyo Ku, 2-1-1 Hongo, Tokyo 1138421, Japan
[6] TokyoUniv Technol, Sch Hlth Sci, Dept Med Technol, Ota Ku, 5-23-22 Nishikamata, Tokyo 1448535, Japan
基金
日本学术振兴会;
关键词
Ultracentrifugation; Inflammation; High-density lipoprotein; Particle size; Serum amyloid A; Laboratory test; HDL FORMATION; APOE;
D O I
10.1016/j.clinbiochem.2018.10.008
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Serum amyloid A (SAA), which is one of the acute phase proteins, alters the structure of HDL by associating with it during circulation. We focused on whether SAA influences the values of HDL-cholesterol (HDL-C) measurements when using a homogeneous assay. Methods: HDLs were isolated by ultracentrifugation from serum samples of 248 patients that were stratified into three groups based on their serum SAA concentrations (low: SAA <= 8 mu g/mL; middle: 8 < SAA <= 100 mu g/mL; and high: SAA > 100 mu g/mL). HDL-C concentrations of the serum samples measured by the homogeneous assay were compared with the total cholesterol concentrations of HDL fractions isolated by ultracentrifugation. Results: HDLs obtained from patients with low SAA concentrations were separated into their general particle sizes and classified as HDL2 and HDL3 by native-gel electrophoresis. On the other hand, HDLs obtained from patients with high SAA concentrations occasionally showed distributions different from the typical sizes of HDL2 and HDL3, such as extremely small or large particles. Nevertheless, HDL-C concentrations measured using the homogeneous assay were strongly correlated with those measured using the ultracentrifugation method, regardless of the SAA concentrations. However, the ratios of HDL-C concentrations obtained by the homogeneous assay to those obtained by the ultracentrifugation method for patients with high SAA concentrations were significantly lower than those of patients with low SAA concentrations. Conclusions: A large amount of SAA attached to HDL altered the HDL particle size but did not essentially affect HDL-C measurement by homogeneous assay.
引用
收藏
页码:97 / 101
页数:5
相关论文
共 50 条
  • [41] Comparison of three methods for measurement of serum high-density lipoprotein cholesterol (HDL-C).
    Costello, R
    Lee, V
    Chesler, R
    Csako, G
    CLINICAL CHEMISTRY, 1996, 42 (06) : 808 - 808
  • [42] Immunochromatographic membrane strip assay system for a single-class plasma lipoprotein cholesterol, exemplified by high-density lipoprotein cholesterol measurement
    Paek, SH
    Jang, MR
    Mok, RS
    Kim, SC
    Kim, HB
    BIOTECHNOLOGY AND BIOENGINEERING, 1999, 62 (02) : 145 - 154
  • [43] MEASUREMENT OF HIGH-DENSITY LIPOPROTEIN CHOLESTEROL IN SERUM - COMPARISON OF 6 ISOLATION METHODS COMBINED WITH ENZYMIC CHOLESTEROL ANALYSIS
    DEMACKER, PNM
    VOSJANSSEN, HE
    HIJMANS, AGM
    VANTLAAR, A
    JANSEN, AP
    CLINICAL CHEMISTRY, 1980, 26 (13) : 1780 - 1786
  • [44] Simple high-density lipoprotein cholesterol assay based on dry chemistry
    Yamada, T
    Nishino, S
    Takubo, T
    Hino, M
    Kitagawa, S
    Tatsumi, N
    CLINICA CHIMICA ACTA, 2002, 320 (1-2) : 79 - 88
  • [45] A two-step homogeneous assay for apolipoprotein E-containing high-density lipoprotein-cholesterol
    Takahashi, Yuji
    Ito, Yasuki
    Sakurai, Toshihiro
    Wada, Norio
    Nagasaka, Atsushi
    Fujikawa, Masato
    Chiba, Hitoshi
    Hui, Shu-Ping
    ANNALS OF CLINICAL BIOCHEMISTRY, 2019, 56 (01) : 123 - 132
  • [46] SERUM TRIGLYCERIDES AND CHOLESTEROL AND SERUM HIGH-DENSITY LIPOPROTEIN CHOLESTEROL IN HIGHLY PHYSICALLY ACTIVE MEN
    LEHTONEN, A
    VIIKARI, J
    ACTA MEDICA SCANDINAVICA, 1978, 204 (1-2): : 111 - 114
  • [47] Effects of serum amyloid A on the structure and antioxidant ability of high-density lipoprotein
    Sato, Megumi
    Ohkawa, Ryunosuke
    Yoshimoto, Akira
    Yano, Kouji
    Ichimura, Naoya
    Nishimori, Madoka
    Okubo, Shigeo
    Yatomi, Yutaka
    Tozuka, Minoru
    BIOSCIENCE REPORTS, 2016, 36
  • [48] High-density Lipoprotein Inhibits Serum Amyloid a -Mediated Inflammasome Activation
    Shridas, Preetha
    de Beer, Maria C.
    Webb, Nancy R.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2018, 38
  • [49] Impact of Serum Amyloid A on High-Density Lipoprotein Composition, Levels, and Function
    De Beer, Maria C.
    Webb, Nancy R.
    Wroblewski, Joanne M.
    Rateri, Debra L.
    Ji, Ailing
    Van der Westhuyzen, Deneys R.
    De Beer, Frederick C.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2009, 29 (07) : E104 - E104
  • [50] SIGNIFICANCE OF HIGH-DENSITY LIPOPROTEIN CHOLESTEROL
    THOMPSON, P
    BORTZ, WM
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 1978, 26 (10) : 440 - 442