DEVELOPMENT AND VALIDATION OF A QUANTITATIVE HS-GC/FID METHOD FOR ALCOHOL ANALYSIS IN BIOLOGICAL SAMPLES: STABILITY ASSESMENT

被引:0
|
作者
Bujaroska, Marija [1 ,5 ]
Bozhinoska, Zorica [1 ]
Vujovic, Maja [3 ,4 ]
Milosavljevic, Biljana [4 ]
Stankov, Aleksandar [1 ]
Ivanovska, Tanja Petreska [2 ]
Poposka, Verica [1 ]
Tozi, Lidija Petrushevska [2 ]
机构
[1] Ss Cyril & Methodius Univ, Inst Forens Med Criminol & Med Deontol, Med Fac, Skopje, North Macedonia
[2] Ss Cyril & Methodius Univ, Fac Pharm, Inst Appl Biochem, Dept Toxicol, Skopje, North Macedonia
[3] Univ Nis, Med Fac, Dept Pharm, Nish, Serbia
[4] Inst Forens Med, Nish, Serbia
[5] Ss Cyril & Methodius Univ, Med Fac, Inst Forens Med Criminol & Med Deontol, 19 Vodnjanska Majka Tereza, Skopje 1000, North Macedonia
来源
ROMANIAN JOURNAL OF LEGAL MEDICINE | 2022年 / 30卷 / 01期
关键词
ethyl alcohol; blood; validation; stability; HEADSPACE GAS-CHROMATOGRAPHY; POSTMORTEM BLOOD; FLAME-IONIZATION; VITREOUS-HUMOR; ETHANOL; ACETALDEHYDE; ANTEMORTEM; METHANOL; ACETONE;
D O I
10.4323/rjlm.2022.53
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Determination of blood alcohol concentration is one of the most common analyses in forensic toxicology laboratory practice. With reference to this, the aim of the present work was to develop a method for quantitative analysis of ethyl alcohol in blood by head space gas chromatography, with n-propanol as an internal standard and at the same time ensuring good resolution of ethyl alcohol and acetone using one capillary column. Validation parameters comprising selectivity, specificity, linearity, accuracy and precision have indicated that the method could be applied in routine analysis of ethyl alcohol in post-mortem and ante-mortem blood samples as well as in other biological fluids, in line with the set criteria based on the revised international guidelines. In post-mortem samples there are many interfering substances due to various reasons (as a result of acidosis, produced in vitro on account of an improper storage of the samples or during the autolysis / putrefaction phase of the body). Because of this occurrence, within the validation procedure, more attention was imparted to the stability of the samples, including processed sample, freeze-thaw and long-term stability estimation. The results of the additional stability tests have shown that applying of preservative significantly improved the stability of the samples by inhibiting the in vitro ethyl alcohol production.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [31] Method development and validation for the GC-FID assay of tributyl phosphate in a phospholipid emulsion
    Kesslen, E
    Thomas, B
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (01) : 155 - 160
  • [32] Development of a GC-FID method for the quantitative determination of polyglycerol polyricinoleate (PGPR) in foods
    Su, Chunxia
    Van der Meeren, Paul
    De Meulenaer, Bruno
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (11): : 1853 - 1866
  • [33] Development, validation and application of a fast GC-FID method for the analysis of volatile compounds in spirit drinks and wine
    Paolini, Mauro
    Tonidandel, Loris
    Larcher, Roberto
    FOOD CONTROL, 2022, 136
  • [34] HS-GC–MS analysis of volatile organic compounds after hyperoxia-induced oxidative stress: a validation study
    Thijs A. Lilien
    Dominic W. Fenn
    Paul Brinkman
    Laura A. Hagens
    Marry R. Smit
    Nanon F. L. Heijnen
    Job B. M. van Woensel
    Lieuwe D. J. Bos
    Reinout A. Bem
    Intensive Care Medicine Experimental, 12
  • [35] Determination of ethanol in blood using headspace gas chromatography with flameionization detector (HS-GC-FID): Validation of a method
    Mihretu, Libargachew Demlie
    Gebru, Asfaw Gebretsadik
    Mekonnen, Kebede Nigussie
    Asgedom, Abraha Gebrekidan
    Desta, Ykalo Hadush
    COGENT CHEMISTRY, 2020, 6 (01):
  • [36] Optimization and Validation of HS-GC/MS Method for the Controlled Release Study of Microencapsulated Specific Bioattractants for Target-Plaguicide Production
    Alonso, Maria Luz
    Gonzalez, Oskar
    Alonso, Rosa Maria
    MOLECULES, 2021, 26 (04):
  • [37] A Quantitative Method of Analysis for Sterol Glycosides in Biodiesel and FAME Using GC-FID
    Montpetit, A.
    Tremblay, A. Y.
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 2016, 93 (04) : 479 - 487
  • [38] HS-GC/MS method development and exposure assessment of volatile organic compounds from food packaging into food simulants
    Hwang, Joung Boon
    Lee, Subi
    Yeum, Jinhwa
    Kim, MeeKyung
    Choi, Jae Chun
    Park, Se-Jong
    Kim, Jeongkwon
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2019, 36 (10): : 1574 - 1583
  • [39] Development and Validation of Novel GC-FID Method for Simultaneous Quantification of Paracetamol and Caffeine in Formulations
    Hussain, Imtiaz
    Baig, Yawar
    Naveed, Sara
    Khan, Muhammad Imran
    Samar, Hafiz Shoaib
    Madni, Asad Ullah
    Sohail, Muhammad Farhan
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2020, 42 (04): : 581 - 590
  • [40] Development and Validation of a GC-FID Method for the Quantitation of 20 Different Acidic and Neutral Cannabinoids
    Gul, Waseem
    Ibrahim, Elsayed A.
    Gul, Sharjeel W.
    Shahzadi, Iram
    Radwan, Mohamed M.
    Chandra, Suman
    Lata, Hemant
    ElSohly, Mahmoud A.
    PLANTA MEDICA, 2023, 89 (06) : 683 - 696