Influence of mounting on the optical surface figure in optical reference surfaces

被引:3
|
作者
Ledl, V. [1 ]
Fortmeier, I. [2 ]
Psota, P. [1 ]
Schulz, M. [2 ]
Matousek, O. [1 ]
Dolecek, R. [1 ]
机构
[1] Inst Plasma Phys ASCR, TOPTEC, Vvi, Sobotecka 1660, Turnov 51101, Czech Republic
[2] Phys Tech Bundesanstalt, Form & Wavefront Metrol WG 4 21, Bundesallee 100, D-38116 Braunschweig, Germany
基金
欧盟地平线“2020”;
关键词
Optics; Overall mechanics design (support structures and materials; vibration; analysis etc); Manufacturing; Interferometry;
D O I
10.1088/1748-0221/15/01/P01005
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The paper presents the effect of mechanical mounting of optical reference elements on their surface shape. Optical reference surfaces are key elements when traceable, highly accurate and precise optical surface measurements are required. In order to calibrate measuring instruments and compare the metrological capabilities of different metrology institutes, universities and other stakeholders, the reference artefacts were developed. Different measurement instruments require a different way of mounting and the reference artefacts are supposed to be useful for reliable and repeatable calibration of a great majority of the instruments worldwide. However, not only their shape was critical, but also the way of mounting was crucial. FEM analyses followed by experiments have revealed an unacceptable surface shape error in the order of hundreds of nanometres in the case of the commonly used screw mount, even for low applied torques. Other mounting options, such as the collet chuck or the Morse taper, are examined by means of FEM analysis and verified by interferometric measurements. It is shown that only the Morse taper can fulfil the strict criterion of less than 30 nm for surface shape deviation due to mounting, which is required in optical surface shape metrology.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] The Simulation Study of the Influence of Surface Error on Optical Properties for Optical Part
    Liu, Taoran
    Qiu, Xing
    Li, He
    Li, Yanli
    Xu, Chao
    Hu, Yong
    Zhou, Xiaoqin
    MATERIAL DESIGN, PROCESSING AND APPLICATIONS, PARTS 1-4, 2013, 690-693 : 3027 - +
  • [32] Influence of implantation on the optical and magneto-optical properties of garnet surface
    Kalandadze, Lali
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2015, 373 : 160 - 163
  • [33] Analysis of optical surfaces by means of surface plasmon spectroscopy
    Fontana, E
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1996, 45 (02) : 399 - 405
  • [34] Characterization of freeform optical surfaces based on surface slope
    Zhao, Xing
    Zheng, Yi
    Zhang, Zan
    Zhang, Juan
    Wang, Ling-Jie
    Wu, Yan-Xiong
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (07): : 1957 - 1964
  • [35] Influence of the number of passes on the quality of reflective optical surfaces
    Duduch, J.
    Porto, A.
    Jasinevicius, R.
    Campos, J.
    2000, CIT, La Serena, Chile (11):
  • [36] Figure error of optical elements induced aberrations of optical system
    Pang Zhihai
    He Tianbin
    10TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: ADVANCED OPTICAL MANUFACTURING AND METROLOGY TECHNOLOGIES, 2021, 12071
  • [37] Gravity induced deflection of a reference plate and tested plane surfaces and its influence on optical measurement with the Fizeau interferometer
    Pokorny, Petr
    Miks, Antonin
    Novak, Pavel
    OPTICS AND MEASUREMENT CONFERENCE 2014, 2015, 9442
  • [38] Measuring optical freeform surfaces using a coupled reference data method
    Kong, L. B.
    Cheung, C. F.
    To, S.
    Lee, W. B.
    Cheng, K. W.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (07) : 2252 - 2260
  • [39] USE OF POWDER FOR MOUNTING OPTICAL-COMPONENTS
    VERKHOVSKII, EB
    SOVIET JOURNAL OF OPTICAL TECHNOLOGY, 1982, 49 (06): : 399 - 400
  • [40] Book review: mounting lenses in optical instruments
    Opt Photonics News, 5 (46):