Spectroscopic observations of beam and source plasma light and testing Cs-deposition monitor in the large area negative ion source for LHD-NBI

被引:0
|
作者
Oka, Y. [1 ]
Tsumori, K. [1 ]
Ikeda, K. [1 ]
Kaneko, O. [1 ]
Nagaoka, K. [1 ]
Osakabe, M. [1 ]
Takeiri, Y. [1 ]
Asano, E. [1 ]
Komada, S. [1 ]
Kondo, T. [1 ]
Sato, M. [1 ]
Shibuya, M. [1 ]
Grisham, L. R. [2 ]
Ikeda, Y. [3 ]
Hanada, M. [3 ]
Umeda, N. [3 ]
机构
[1] Natl Inst Nat Sci, Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
[2] Princeton Plasma Phys Lab, Princeton, NJ 08543 USA
[3] Japan Atom Energy Agcy, Ibaraki 3190193, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 02期
关键词
D O I
10.1063/1.2819322
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the large area negative ion source for the LHD negative-ion-(H(-))-based neutral beam system, (1) we used the spectrometer to measure caesium lines in the source plasma during beam shots. (11) With Doppler-shifted measurements, the H, line at three different locations along the beam as well as the spectrum profile for cases of different plasma grid areas. (111) Caesium deposition monitor with a high speed shutter was tested to measure the weight of the deposited Cs layer. In the observation, cleaner spectra of Doppler-shifted H, line with only a small level of background light were obtained at a new observation port which viewed the blueshifted light in the drift region after the accelerator of a LHD ion source. Both the amounts of Cs I (852 nm, neutral Cs(0)) and Cs II (522 nm, Cs(+)) in the source plasma light rose sharply when beam acceleration began, and continued rising during a 10 s pulse. It was thought that this was because the cesium was evaporated/sputtered from the source back plate by the back-streaming positive ions. Cs deposition rate to the crystal sensor measured by adjusting the shutter open time was evaluated to be 2.9 nanograms/s cm(2) for preliminary testing. More neutral Cs tended to be evolved in the source after arc discharge. Much Cs could be consumed in a high rate-pulsed operation (such as LHD source). (C) 2008 American Institute of Physics.
引用
收藏
页数:4
相关论文
共 19 条
  • [1] Development of large scale negative ion source for LHD-NBI
    Tsumori, K
    Takanashi, T
    Asano, S
    Osakabe, M
    Takeiri, Y
    Oka, Y
    Asano, E
    Kawamoto, T
    Akiyama, R
    Okuyama, T
    Suzuki, Y
    Kaneko, O
    PRODUCTION AND NEUTRALIZATION OF NEGATIVE IONS AND BEAMS / PRODUCTION AND APPLICATION OF LIGHT NEGATIVE IONS, 1998, 439 : 93 - 104
  • [2] Depth of Influence on the Plasma by Beam Extraction in a Negative Hydrogen Ion Source for NBI
    Geng, Shaofei
    Tsumori, Katsuyoshi
    Nakano, Haruhisa
    Kisaki, Masashi
    Ikeda, Katsunori
    Osakabe, Masaki
    Nagaoka, Ken-ichi
    Takeiri, Yasuhiko
    Shibuya, Masayuki
    Kaneko, Osamu
    PLASMA AND FUSION RESEARCH, 2016, 11 (11):
  • [3] Recent Studies of Hydrogen Negative Ion Source and Beam Production for NBI in Large Helical Device
    Ikeda, Katsunori
    Geng, Shaofei
    Tsumori, Katsuyoshi
    Nakano, Haruhisa
    Kisaki, Masashi
    Nagaoka, Kenichi
    Osakabe, Masaki
    Kaneko, Osamu
    Takeiri, Yasuhiko
    PLASMA AND FUSION RESEARCH, 2016, 11 (11):
  • [4] Plasma And Beam Homogeneity Of The RF-Driven Negative Hydrogen Ion Source For ITER NBI
    Fantz, U.
    Franzen, P.
    Kraus, W.
    Wuenderlich, D.
    Gutser, R.
    Berger, M.
    NEGATIVE IONS, BEAMS AND SOURCES, 2009, 1097 : 265 - 274
  • [5] The origin of beam non-uniformity in a large Cs-seeded negative ion source
    Hanada, M
    Seki, T
    Takado, N
    Inoue, T
    Mizuno, T
    Hatayama, A
    Kashiwagi, M
    Sakamoto, K
    Taniguchi, M
    Watanabe, K
    NUCLEAR FUSION, 2006, 46 (06) : S318 - S323
  • [6] Spatial Distributions of Charged Particles and Plasma Potential before and during Beam Extraction in a Negative Hydrogen Ion Source for NBI*)
    Geng, Shaofei
    Tsumori, Katsuyoshi
    Nakano, Haruhisa
    Kisaki, Masashi
    Takeiri, Yasuhiko
    Osakabe, Masaki
    Ikeda, Katsunori
    Nagaoka, Kenichi
    Kaneko, Osamu
    Shibuya, Masayuki
    Group, Nifs Nbi
    Plasma and Fusion Research, 2015, 10 : 1 - 4
  • [7] Optimization of Cs deposition in the 1/3 scale hydrogen negative ion source for the large helical device-neutral beam injection system
    Oka, Y
    Takeiri, Y
    Belchenko, YI
    Hamabe, M
    Kaneko, O
    Tsumori, K
    Osakabe, M
    Asano, E
    Kawamoto, T
    Akiyama, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1379 - 1384
  • [8] CHARACTERISTICS OF A SHEET PLASMA AND ITS APPLICATION TO A LARGE EXTRACTION AREA NEGATIVE-ION SOURCE
    WADA, M
    TAKESHIMA, S
    TSUDA, H
    SASAO, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (01): : 430 - 432
  • [9] Improvement of beam uniformity by magnetic filter optimization in a Cs-seeded large negative-ion source
    Hanada, M
    Seki, T
    Takado, N
    Inoue, T
    Tobari, H
    Mizuno, T
    Hatayama, A
    Dairaku, M
    Kashiwagi, M
    Sakamoto, K
    Taniguchi, M
    Watanabe, K
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (03):
  • [10] Optimization of a large-area grid electrode for negative ion source in fusion neutral beam injector
    Wang, Jinhong
    Wang, Yan
    Yang, Yuwen
    Gu, Yuming
    Xie, Yahong
    Liang, Lizhen
    Wei, Jianglong
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (02)