Recent Studies of Hydrogen Negative Ion Source and Beam Production for NBI in Large Helical Device

被引:5
|
作者
Ikeda, Katsunori [1 ]
Geng, Shaofei [2 ]
Tsumori, Katsuyoshi [1 ]
Nakano, Haruhisa [1 ]
Kisaki, Masashi [1 ]
Nagaoka, Kenichi [1 ]
Osakabe, Masaki [1 ]
Kaneko, Osamu [1 ]
Takeiri, Yasuhiko [1 ]
机构
[1] Natl Inst Fus Sci, 322-6 Oroshi, Toki, Gifu 5095292, Japan
[2] SOKENDAI, 322-6 Oroshi, Toki, Gifu 5095292, Japan
来源
PLASMA AND FUSION RESEARCH | 2016年 / 11卷 / 11期
关键词
NBI; negative ion source; extraction region; negative-ion rich plasma; particle flow;
D O I
10.1585/pfr.11.2505038
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The state of hydrogen plasma in the extraction region in a hydrogen negative-ion (H-) source for NBI has been investigated. We clearly observe an improvement of H- density owing to the surface production effect with Cs seeding. H- ions are widely distributed in the extraction region which is obtained by movable cavity ring down (CRD). We confirm a negative ion rich plasma with a few electrons in the extraction region, which state is important for reduction of electron contamination in extracting beam. An extraction area is reached 30 mm from the PG surface, which is measured by a 2D imaging diagnostic for Ha emission. We find the insensitive area for H- extraction at the PG surface between the apertures. Negative ions produced at the surface are considered to have been supplied in the extraction region. The flow velocity of H- ions is obtained by a four-pin Langmuir probe using a photodetachment technique with an Nd:YAG laser. H- ion flows from the plasma grid surface, and its direction drastically changes at 20 mm from the production surface. This flow behavior is considered to be an important characteristic for improving H-density in the extraction region. (C) 2016 The Japan Society of Plasma Science and Nuclear Fusion Research
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Negative hydrogen ion source development for large helical device neutral beam injector (invited)
    Takeiri, Y
    Kaneko, O
    Tsumori, K
    Oka, Y
    Osakabe, M
    Ikeda, K
    Asano, E
    Kawamoto, T
    Akiyama, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (02): : 1225 - 1230
  • [2] Improvement of a large negative ion source for the Large Helical Device neutral beam injector
    Takeiri, Y
    Ikeda, K
    Hamabe, M
    Osakabe, M
    Kaneko, O
    Oka, Y
    Tsumori, K
    Asano, E
    Kawamoto, T
    Sato, M
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (02): : 1087 - 1089
  • [3] Construction of negative-ion-based NBI system in Large Helical Device
    Takeiri, Y
    Kaneko, O
    Oka, Y
    Tsumori, K
    Osakabe, M
    Akiyama, R
    Kawamoto, T
    Asano, E
    [J]. 17TH IEEE/NPSS SYMPOSIUM ON FUSION ENGINEERING, VOLS 1 AND 2, 1998, : 409 - 412
  • [4] IMPROVEMENT OF THE LARGE CURRENT NEGATIVE HYDROGEN-ION SOURCE FOR NEUTRAL INJECTION IN THE LARGE HELICAL DEVICE
    TSUMORI, K
    ANDO, A
    OKUYAMA, T
    SUZUKI, Y
    KANEKO, O
    OKA, Y
    TAKEIRI, Y
    AKIYAMA, R
    KAWAMOTO, T
    SEKO, K
    KURODA, T
    [J]. FUSION ENGINEERING AND DESIGN, 1995, 26 (1-4) : 473 - 483
  • [5] Depth of Influence on the Plasma by Beam Extraction in a Negative Hydrogen Ion Source for NBI
    Geng, Shaofei
    Tsumori, Katsuyoshi
    Nakano, Haruhisa
    Kisaki, Masashi
    Ikeda, Katsunori
    Osakabe, Masaki
    Nagaoka, Ken-ichi
    Takeiri, Yasuhiko
    Shibuya, Masayuki
    Kaneko, Osamu
    [J]. PLASMA AND FUSION RESEARCH, 2016, 11 (11):
  • [6] Improvement of accelerator of negative ion source on the Large Helical Device
    Kisaki, M.
    Ikeda, K.
    Osakabe, M.
    Tsumori, K.
    Nakano, H.
    Geng, S.
    Nagaoka, K.
    Kaneko, O.
    Takeiri, Y.
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [7] Recent Progress in the Negative-Ion-Based Neutral Beam Injectors in Large Helical Device
    Takeiri, Y.
    Tsumori, K.
    Ikeda, K.
    Osakabe, M.
    Nagaoka, K.
    Oka, Y.
    Asano, E.
    Kondo, T.
    Sato, M.
    Shibuya, M.
    Komada, S.
    Kaneko, O.
    [J]. NEGATIVE IONS, BEAMS AND SOURCES, 2009, 1097 : 470 - 479
  • [8] High-current negative-ion beam acceleration with a large negative-ion source for large helical device-neutral beam injection system
    Takeiri, Y
    Osakabe, M
    Tsumori, K
    Oka, Y
    Kaneko, O
    Asano, E
    Kawamoto, T
    Akiyama, R
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (02): : 977 - 979
  • [9] High-current negative-ion beam acceleration with a large negative-ion source for large helical device-neutral beam injection system
    Takeiri, Y.
    Osakabe, M.
    Tsumori, K.
    Oka, Y.
    Kaneko, O.
    Asano, E.
    Kawamoto, T.
    Akiyama, R.
    [J]. Review of Scientific Instruments, 1998, 69 (2 pt 2):
  • [10] Deuterium experiment with large-scale negative ion source for large helical device
    Nakano, H.
    Kisaki, M.
    Ikeda, K.
    Tsumori, K.
    Nagaoka, K.
    Haba, Y.
    Masaki, S.
    Fujiwara, Y.
    Kamio, S.
    Osakabe, M.
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (59)