Signal to noise ratio in simulations of time-of-flight positron emission tomography

被引:0
|
作者
Harrison, RL [1 ]
Alessio, AM [1 ]
Kinahan, PE [1 ]
Lewellen, TK [1 ]
机构
[1] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Time-of-flight (TOF) positron emission tomography (PET) can improve signal-to-noise ratio (SNR) relative to conventional PET by improving coincidence localization and reducing random coincidences. Several time-of-flight positron emission tomographs were developed in the 1980s and early 1990s. However, interest in time-of-flight waned because of the low stopping power and light yield of the scintillators available at that time. Now newly discovered scintillators with greater light yield and/or stopping power, along with advances in photomultiplier tubes and electronics, are rekindling interest in TOR To facilitate investigations into the utility of TOF, we have modified the SimSET simulation to track and bin TOF differences between coincidence photons. Images were reconstructed from simulated data using confidence-weighted backprojection and filtered backprojection. These images were used to investigate the effect of TOF on SNR. SNR improves dramatically with improved TOF resolution. However, the improvement is somewhat less than that predicted by a widely used theoretical model.
引用
收藏
页码:4080 / 4083
页数:4
相关论文
共 50 条
  • [21] SOME SIGNAL-PROCESSING ASPECTS OF TIME-OF-FLIGHT POSITRON EMISSION TOMOGRAPHY (TOFPET) SYSTEM IMPLEMENTATION
    PHILIPPE, EA
    MULLANI, N
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (01) : 715 - 719
  • [22] Time-of-flight positron emission tomography using liquid xenon scintillation
    Doke, T.
    Kikuchi, J.
    Nishikido, F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 569 (03): : 863 - 871
  • [23] Relationship between the image quality and noise-equivalent count in time-of-flight positron emission tomography
    Maebatake, Akira
    Akamatsu, Go
    Miwa, Kenta
    Tsutsui, Yuji
    Himuro, Kazuhiko
    Baba, Shingo
    Sasaki, Masayuki
    ANNALS OF NUCLEAR MEDICINE, 2016, 30 (01) : 68 - 74
  • [24] Evaluation of Image Signal-to-Noise Ratio in Time-of-flight PET
    Clementel, Enrico
    Vandenberghe, Stefaan
    Karp, Joel S.
    Surti, Suleman
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3917 - 3921
  • [25] Event-Time Determination by Waveform Analysis for Time-of-Flight Positron Emission Tomography
    Kao, Chien-Min
    Kim, Heejong
    Chen, Chin-Tu
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3874 - 3879
  • [26] Single Channel Optimization for an Endoscopic Time-of-Flight Positron Emission Tomography Detector
    Garutti, Erika
    Gadow, Karsten
    Goettlich, Martin
    Silenzi, Alessandro
    Xu, Chen
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 54 - 58
  • [27] Image quality improvements with time-of-flight positron emission tomography for molecular imaging
    Manjeshwar, RM
    Shao, YP
    Jansen, FP
    2005 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1-5: SPEECH PROCESSING, 2005, : 853 - 856
  • [28] HRFlexToT: A High Dynamic Range ASIC for Time-of-Flight Positron Emission Tomography
    Sanchez, David
    Gomez, Sergio
    Mauricio, Joan
    Freixas, Lluis
    Sanuy, Andreu
    Guixe, Gerard
    Lopez, Albert
    Manera, Rafel
    Marin, Jesus
    Perez, Jose M.
    Picatoste, Eduardo
    Pujol, Carolina
    Sanmukh, Anand
    Rato, Pedro
    Vela, Oscar
    Gascon, David
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2022, 6 (01) : 51 - 67
  • [29] Pilot study of timing performance for time-of-flight positron emission tomography detector
    Liu, Jun-Hui
    Li, Dao-Wu
    Zhang, Zhi-Ming
    Liao, Yan-Fei
    Huang, Xian-Chao
    Wang, Pei-Lin
    Chen, Yan
    Yun, Ming-Kai
    Feng, Bao-Tong
    Shuai, Lei
    Wang, Bao-Yi
    Zhang, Tian-Bao
    Wei, Long
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (12): : 1522 - 1526
  • [30] TIME-OF-FLIGHT POSITRON-EMISSION TOMOGRAPHY STATUS RELATIVE TO CONVENTIONAL PET
    TERPOGOSSIAN, MM
    FICKE, DC
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (01) : 136 - 137