The neutron component of two high-energy photon reference fields

被引:1
|
作者
Roettger, S. [1 ]
Schaeler, K. [2 ]
Behrens, R. [1 ]
Nolte, R. [1 ]
Wissmann, F. [2 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
[2] Univ Halle Wittenberg, D-06108 Halle, Germany
关键词
D O I
10.1093/rpd/ncm083
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The 4.4 MeV photon reference field described in ISO 4037 is produced by the C-12(P,P',)C-12 (E-x = 4.4389 MeV) reaction using a thick elemental carbon target and a proton beam with an energy of 5.7 MeV. The relative abundance of the isotope C-13 in elemental carbon is 1.10%. Therefore, the 4.4 MeV photon field is contaminated by neutrons produced by the C-13( p,n) N-13 reaction (Q = -3.003 MeV). The ambient dose equivalent H*(10) produced by these neutrons is of the same order of magnitude as the ambient dose equivalent produced by the 4.4 MeV photons. For the calibration of dosemeters, especially those also sensitive to neutrons, the spectral fluence distribution of these neutrons has to be known in detail. On the other hand, a mixed photon/neutron field is very useful for the calibration of tissue-equivalent proportional counters (TEPC), if this field combines a high-linear energy transfer (LET) component produced by low-energy neutrons and a low-LET component resulting from photons with about the same ambient dose equivalent and energies up to 7 MeV. Such a mixed field was produced at the PTB accelerator facility using a thin CaF2 + C-nat target and a 5.7 MeV proton beam.
引用
收藏
页码:404 / 407
页数:4
相关论文
共 50 条
  • [31] Spectrum of two quasiequal-energy electrons ejected by a high-energy photon
    Kornberg, MA
    Miraglia, JE
    EUROPEAN PHYSICAL JOURNAL D, 2000, 12 (01): : 45 - 51
  • [32] High-energy neutron spectrometry
    V. I. Yurevich
    Physics of Particles and Nuclei, 2012, 43 : 367 - 418
  • [33] High-energy neutron spectrometry
    Yurevich, V. I.
    PHYSICS OF PARTICLES AND NUCLEI, 2012, 43 (03) : 367 - 418
  • [34] HOW SHOULD THE INDIVIDUAL DOSE EQUIVALENT BE MEASURED IN HIGH-ENERGY PHOTON FIELDS
    GULDBAKKE, S
    SCHAFFLER, D
    KRAMER, HM
    RADIATION PROTECTION DOSIMETRY, 1989, 28 (1-2) : 127 - 129
  • [35] A new procedure for dose measurements in mixed high-energy electron and photon fields
    Gargioni, E
    Büermann, L
    Kramer, HM
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 455 - 456
  • [36] Cross section of high-energy photon splitting in the electric fields of heavy atoms
    Lee, RN
    Milstein, AI
    Strakhovenko, VM
    PHYSICAL REVIEW A, 1998, 58 (03): : 1757 - 1764
  • [37] Energy calibration at high-energy photon colliders
    Telnov, V. I.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [38] High-energy two-electron capture with emission of a single photon
    Drukarev, E. G.
    Mikhailov, A. I.
    Mikhailov, I. A.
    Scheid, W.
    PHYSICAL REVIEW A, 2007, 76 (06):
  • [39] CLINICAL COMPARISONS OF TWO-DIMENSIONAL AND 3-DIMENSIONAL ISODOSE DISTRIBUTIONS FOR NEUTRON AND HIGH-ENERGY PHOTON RADIOTHERAPY
    SONTAG, MR
    ALTSCHULER, MD
    BLOCH, P
    CURLEY, RF
    MEDICAL PHYSICS, 1983, 10 (05) : 738 - 738
  • [40] Photonuclear and Two-Photon Interactions at High-Energy Nuclear Colliders
    Klein, Spencer R.
    Steinberg, Peter
    ANNUAL REVIEW OF NUCLEAR AND PARTICLE SCIENCE, VOL 70, 2020, 70 : 323 - 354