Transient Flow Boiling and Maldistribution Characteristics in Heated Parallel Channels Induced by Flow Regime Oscillations

被引:2
|
作者
Kingston, Todd A. [1 ]
Olson, Brian D. [2 ]
Weibel, Justin A. [3 ]
Garimella, Suresh, V [4 ]
机构
[1] Iowa State Univ, Ctr Multiphase Flow Res & Educ, Dept Mech Engn, Ames, IA 50011 USA
[2] Naval Surface Warfare Ctr Crane Div, Crane, IN 47522 USA
[3] Purdue Univ, Cooling Technol Res Ctr, Sch Mech Engn, W Lafayette, IN 47907 USA
[4] Univ Vermont, Burlington, VT 05405 USA
关键词
Flow boiling; flow instability; flow maldistribution; flow regime; parallel microchannels; transient heating; twophase flow; THERMAL-FLUIDIC CHARACTERIZATION; PRESSURE-DROP; INSTABILITY; MICROCHANNELS; FLUX;
D O I
10.1109/TCPMT.2021.3106226
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Flow boiling provides an effective means of heat removal but can suffer from thermal and hydrodynamic transients that compromise heat transfer performance and trigger device failure. In this study, the transient flow boiling characteristics in two thermally isolated, hydrodynamically coupled parallel microchannels are investigated experimentally. High-speed flow visualization is synchronized to high-frequency heat flux, wall temperature, pressure drop, and mass flux measurements to provide time-resolved characterization. Two constant and two transient heating conditions are presented. For a constant heat flux of 63 kW/m(2) into each channel, boiling occurs continuously in both channels and the parallel channel instability is observed to occur at 15 Hz. Time-periodic oscillations in the pressure drop and average mass flux are observed, but corresponding oscillations in the wall temperatures are virtually nonexistent at this condition. At a slightly lower constant heat flux of 60 kW/m(2), boiling remains continuous in one of the channels, but the other channel experiences time-periodic flow regime oscillations between single-phase and two-phase flow. At this condition, extreme time-periodic wall temperature oscillations are observed in both channels with a long period (similar to 7 s) due to oscillations in the severity of the flow maldistribution. For the transient heating conditions, square-wave heating profiles oscillating between different heat flux levels are applied to the channels. Because of their relatively high frequency, the heating transients are attenuated by the microchannel walls, resulting in effectively constant heating conditions and flow boiling characteristics like that of the aforementioned constant heating conditions. This study illustrates the susceptibility of parallel two-phase heat sinks to flow maldistribution, particularly when undergoing transient flow regime oscillations.
引用
收藏
页码:1615 / 1624
页数:10
相关论文
共 50 条
  • [31] Liquid blockage and flow maldistribution of two-phase flow in two parallel thin micro-channels
    Wu, Jingtian
    Wang, Yun
    APPLIED THERMAL ENGINEERING, 2021, 182
  • [32] Transient thermal characteristics of silicon microchannel flow boiling
    Ren, Congcong
    Han, Jingwei
    Chang, Wei
    Li, Chen
    Li, Wenming
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2025, 211
  • [33] Vibration characteristic of heated rod induced by subcooled flow boiling
    Nematollahi, MR
    Toda, S
    Hashizume, H
    Yuki, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1999, 36 (07) : 575 - 583
  • [34] Stability analysis and maldistribution control of two-phase flow in parallel evaporating channels
    Zhang, TieJun
    Wen, John T.
    Julius, Agung
    Peles, Yoav
    Jensen, Michael K.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (25-26) : 5298 - 5305
  • [35] Multidimensional Heat Transfer and Flow Boiling Curve Measurements in Single-Side-Heated Flow Channels
    Boyd, R. D.
    May, A. M.
    Cofie, P.
    Martin, R.
    FUSION SCIENCE AND TECHNOLOGY, 2016, 70 (03) : 448 - 460
  • [36] Characteristics of flow boiling oscillations in silicon microchannel heat sinks
    Muwanga, R.
    Hassan, I.
    MacDonald, R.
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2007, 129 (10): : 1341 - 1351
  • [37] Experimental Investigation of the Characteristics of Flow Boiling Oscillations in a Vertical Minichannel
    Li, Chong
    Chen, Deqi
    Lu, Qi
    He, Xueqiang
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (15) : 5401 - 5412
  • [38] An experimental investigation of the effect of thermal coupling between parallel microchannels undergoing boiling on the Ledinegg instability-induced flow maldistribution
    Miglani, Ankur
    Weibel, Justin A.
    Garimella, Suresh, V
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2021, 139
  • [39] FLOW BOILING IN TRANSPARENT HEATED MICROTUBE
    Kawanami, Osamu
    Huang, Shih-Che
    Kawakami, Kazunari
    Honda, Itsuro
    Kawashima, Yousuke
    Ohta, Haruhiko
    PROCEEDINGS OF THE 6TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS, AND MINICHANNELS, PTS A AND B, 2008, : 685 - 691
  • [40] FLOW OF BOILING WATER IN HEATED PIPES
    SHOTKIN, LM
    NUCLEAR SCIENCE AND ENGINEERING, 1966, 26 (03) : 293 - &