Harmonics and powers of doubly fed induction generators at balanced sinusoidal voltages

被引:0
|
作者
Schostan, Steffen [1 ]
Dettmann, Klaus-Dieter [1 ]
Purellku, Ilir [1 ]
Schulz, Detlef [1 ]
机构
[1] Univ Fed Armed Forces Hamburg, Helmut Schmidt Univ, D-22043 Hamburg, Germany
来源
PRZEGLAD ELEKTROTECHNICZNY | 2011年 / 87卷 / 01期
关键词
asymmetries; balanced sinusoidal voltage; DFIG; harmonics; wind turbine; power components;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurements at a test-bench of a wind energy converter performed with an ideal balanced and sinusoidal voltage source instead of a grid are necessary for the identification of the harmonics or subharmonics caused by the generator and converter. The produced significant frequencies as well as their interaction with the voltage source are analyzed. The stator side collective power components are calculated and their effect on the time variable asymmetry of the stator current of the three-phase system is investigated.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 50 条
  • [31] The Study on Grid Stability of Doubly Fed Induction Generators with Supercapacitors
    Guo, Chiyue
    Liu, Yili
    Ge, Junchen
    2024 4TH POWER SYSTEM AND GREEN ENERGY CONFERENCE, PSGEC 2024, 2024, : 127 - 131
  • [32] Reduction of stator current harmonics in doubly-fed induction machines
    Grune, R.
    Saniter, C.
    Wood, A. R.
    Hanitsch, R.
    2006 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION, VOLS 1-3, 2006, : 22 - +
  • [33] Stator current harmonics analysis of doubly-fed induction generator
    Wang, Zhong
    Sun, Yuanzhang
    Li, Guojie
    Li, Zhiguo
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2010, 30 (06): : 1 - 5
  • [34] Field tests and modelling of a wind form with doubly fed induction generators
    Meisingset, M
    Ohnstad, RM
    Uhlen, K
    Strand, LR
    WIND ENERGY, 2005, 8 (03) : 333 - 344
  • [35] MRAS observer for sensorless control of standalone doubly fed induction generators
    Cárdenas, R
    Peña, R
    Proboste, J
    Asher, G
    Clare, J
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (04) : 710 - 718
  • [36] Accurate assessment of the output energy from the doubly fed induction generators
    El-Kharashi, Eyhab
    Farid, Azmy Wadie
    ENERGY, 2015, 93 : 406 - 415
  • [37] A criterion for the Hopf bifurcation and the pathway to chaos of doubly fed induction generators
    Chen, Wei
    Li, Qiangqiang
    Wei, Zhanhong
    Li, Jiangtao
    Wang, Kun
    ELECTRICAL ENGINEERING, 2023, 105 (5) : 2595 - 2605
  • [38] Control Strategies of Doubly Fed Induction Generators to Support Grid Voltage
    Salles, M. B. C.
    Cardoso, J. R.
    Grilo, A. P.
    Rahmann, C.
    Hameyer, K.
    2009 IEEE INTERNATIONAL ELECTRIC MACHINES & DRIVES CONFERENCE, VOLS 1-3, 2009, : 1551 - 1551
  • [39] Doubly fed induction generators for wind turbines - modeling the steady state
    Ofner, G.
    Handgruber, P.
    Seebacher, R.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2011, 128 (05): : 174 - 180
  • [40] Design and Analysis of Rotary Transformer for Brushless Doubly Fed Induction Generators
    Zhong, Hui
    Wu, Chao
    Wang, Yingjie
    PROCEEDINGS OF THE 2018 13TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2018), 2018, : 1416 - 1419