A Fluorescence Kinetic-Based Aptasensor Employing Stilbene Isomerization for Detection of Thrombin

被引:6
|
作者
Zeng, Xinling [1 ,2 ]
Zhou, Qing [1 ,2 ]
Wang, Liyan [2 ]
Zhu, Xiaoxian [2 ]
Cui, Kuiyan [2 ]
Peng, Xinsheng [2 ,3 ]
Steele, Terry W. J. [4 ]
Chen, Huizhi [2 ,3 ]
Xu, Hui [1 ]
Zhou, Yubin [2 ,3 ]
机构
[1] Guangzhou Univ Chinese Med, Key Lab Chinese Med Resource Lingnan, Minist Educ, Guangzhou 510006, Peoples R China
[2] Guangdong Med Univ, Sch Pharm, Dongguan 523808, Peoples R China
[3] Guangdong Zhanjiang Marine Biomed Res Inst, Marine Med Res Inst Guangdong Zhanjiang, Zhanjiang 524023, Peoples R China
[4] Nanyang Technol Univ, Coll Engn, Sch Mat Sci & Engn, 50 Nanyang Ave, Singapore 639798, Singapore
关键词
thrombin; aptamer; biosensors; photoisomerization; fluorescence; kinetic mode; TRANS-STILBENES; ADAPTIVE BINDING; APTAMER; DNA; QUADRUPLEX; CIS; SEPARATION; BIOSENSOR; GRAPHENE; PLATFORM;
D O I
10.3390/ma14226927
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
It is important to detect thrombin due to its physiological and pathological roles, where rapid and simple analytical approaches are needed. In this study, an aptasensor based on fluorescence attenuation kinetics for the detection of thrombin is presented, which incorporates the features of stilbene and aptamer. We designed and synthesized an aptasensor by one-step coupling of stilbene compound and aptamer, which employed the adaptive binding of the aptamer with thrombin to cause a change in stilbene fluorescence attenuation kinetics. The sensor realized detection of thrombin by monitoring the variation in apparent fluorescence attenuation rate constant (k(app)), which could be further used for probing of enzyme-aptamer binding. In comprehensive studies, the developed aptasensor presented satisfactory performance on repeatability, specificity, and regeneration capacity, which realized rapid sensing (10 s) with a limit of detection (LOD) of 0.205 mu M. The strategy was successful across seven variants of thrombin aptasensors, with tunable k(app) depending on the SITS (4-Acetamido-4 & PRIME;-isothiocyanato-2,2 & PRIME;-stilbenedisulfonic acid disodium salt hydrate) grafting site. Analyte detection mode was demonstrated in diluted serum, requiring no separation or washing steps. The new sensing mode for thrombin detection paves a way for high-throughput kinetic-based sensors for exploiting aptamers targeted at clinically relevant proteins.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] A label-free electrochemical aptasensor based on the catalysis of manganese porphyrins for detection of thrombin
    Zheng, Yingning
    Yuan, Yali
    Chai, Yaqin
    Yuan, Ruo
    BIOSENSORS & BIOELECTRONICS, 2015, 66 : 585 - 589
  • [32] Electrochemical aptasensor based on conductive supramolecular polymer hydrogels for thrombin detection with high selectivity
    Wang, Xinyan
    Gao, Fengxian
    Gong, Yiyu
    Liu, Guotao
    Zhang, Yu
    Ding, Caifeng
    TALANTA, 2019, 205
  • [33] An Evaluation of Three Kinematic Methods for Gait Event Detection Compared to the Kinetic-Based 'Gold Standard'
    Zahradka, Nicole
    Verma, Khushboo
    Behboodi, Ahad
    Bodt, Barry
    Wright, Henry
    Lee, Samuel C. K.
    SENSORS, 2020, 20 (18) : 1 - 15
  • [34] Ultrasensitive and universal fluorescent aptasensor for the detection of biomolecules (ATP, adenosine and thrombin) based on DNA/Ag nanoclusters fluorescence light-up system
    Zhu, Ying
    Hu, Xiao-chun
    Shi, Shuo
    Gao, Ru-ru
    Huang, Hai-liang
    Zhu, Yan-yan
    Lv, Xiao-yan
    Yao, Tian-ming
    BIOSENSORS & BIOELECTRONICS, 2016, 79 : 205 - 212
  • [35] Highly Sensitive Fluorescent Aptasensor for Thrombin Detection Based on Competition Triggered Rolling Circle Amplification
    Zhang Song-Bai
    Zheng Li-Ying
    Hu Xia
    Shen Guang-Yu
    Liu Xue-Wen
    Shen Guo-Li
    Yu Ru-Qin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (11) : 1688 - 1693
  • [36] Label-free electrochemical aptasensor for thrombin detection based on the nafion@graphene as platform
    Sun, Tao
    Wang, Li
    Li, Na
    Gan, Xianxue
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2011, 34 (09) : 1081 - 1085
  • [37] Fluorescence aptasensor based on competitive-binding for human neutrophil elastase detection
    He, Jing-Lin
    Wu, Zai-Sheng
    Zhang, Song-Bai
    Shen, Guo-Li
    Yu, Ru-Qin
    TALANTA, 2010, 80 (03) : 1264 - 1268
  • [38] Enzyme-free fluorescence aptasensor for amplification detection of human thrombin via target-catalyzed hairpin assembly
    Zheng, Ai-Xian
    Wang, Jin-Ru
    Li, Juan
    Song, Xiao-Rong
    Chen, Guo-Nan
    Yang, Huang-Hao
    BIOSENSORS & BIOELECTRONICS, 2012, 36 (01): : 217 - 221
  • [39] Sensitive Electrochemical Aptasensor for Thrombin Detection Based on Graphene Served as Platform and Graphene Oxide as Enhancer
    He, Chun
    Xu, Zenghong
    Sun, Tao
    Wang, Li
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2014, 172 (02) : 1018 - 1026
  • [40] Label-free electrochemical aptasensor for thrombin detection based on the nafion@graphene as platform
    Tao Sun
    Li Wang
    Na Li
    Xianxue Gan
    Bioprocess and Biosystems Engineering, 2011, 34 : 1081 - 1085