Discussion of Design Method and Optimization on Airflow Distribution in a Large-Space Building with Stratified Air-Conditioning System

被引:0
|
作者
Huang, C. [1 ]
Wang, X. [1 ]
机构
[1] Shanghai Univ Sci & Technol, Coll Urban Construct & Environm Engn, Shanghai 201800, Peoples R China
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Indoor air distribution is a major concern in designing indoor thermal environment of a large space, which is different from normal buildings. Today, stratified air conditioning is a common choice for large-space buildings. Indoor air distribution with the stratified air conditioning is affected by many design parameters. These parameters have direct effects on thermal comfort, environment noise and energy consumption. Selection of these parameters thus becomes the key problem in design of indoor thermal environment in a large space. In this paper: a large-space building is taken as the study object. It was found that the cooling load varies linearly with the stratified height. The calculations of the air distributions were performed under the conditions of different stratified height, diameter and quantity of the blast nozzles. Based on calculated results, the alignment charts were plotted in an effort to determine the design parameters such as the height, the diameter and the number of blast nozzles and their selection range for a large-space building. According to the charts, the relationship of design parameters and their optimized selection are analyzed. It is clear that the lower the height, the less the energy consumption demand is, however; the noise level would be higher Based on above results, an optimized and practical methodology is formulated for the design of the air distribution in a large space.
引用
收藏
页码:345 / 349
页数:5
相关论文
共 50 条
  • [21] Thermal stratification level of low sidewall air supply with air-conditioning system in large space
    黄晨
    蔡宁
    高雪垒
    Journal of Central South University, 2009, 16 (S1) : 166 - 170
  • [23] Bi-level Optimization Method of Air-conditioning System Based on Office Building Energy Storage Characteristics
    Wang, Qingze
    Chen, Xingying
    Ji, Li
    Liao, Yingchen
    Yu, Kun
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [24] Thermal stratification level of low sidewall air supply with air-conditioning system in large space
    Huang Chen
    Cai Ning
    Gao Xue-lei
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 166 - 170
  • [25] Numerical simulation of air-conditioning temperature field in semi-opening large space building
    Gong, GC
    Luo, QH
    Tang, GF
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 277 - 285
  • [26] Energy Performance Evaluation of an Air-Conditioning System in a Large Scale Office Building by Commissioning
    Zhang, Weijie
    Liu, Jiuling
    Jia, Jieqing
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 351 - 358
  • [27] A Study on the Optimization of Control Strategy of a Thermal Energy Storage System for Building Air-Conditioning
    Khushairi, M. M.
    Abdullah, H.
    Hazran, H.
    2ND INTERNATIONAL BUILDING CONTROL CONFERENCE, 2011, 20
  • [28] Comprehensive clustering method to determine coincident design day for air-conditioning system design
    Fang, Zhengcheng
    Chen, Youming
    Ai, Zhengtao
    Li, Hongqiang
    BUILDING AND ENVIRONMENT, 2022, 216
  • [29] A Preliminary Research on Load Calculation Method of Stratified Air Conditioning System with Low-sidewall Air Inlets and Middle-height Air Outlets in Large Space Building
    Huang, Chen
    Yue, Jing
    Bai, Tianyu
    Lv, Liugen
    Zhang, Qianru
    Chen, Jianchang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2561 - 2568
  • [30] Study on a new optimum design method for the air-conditioning chilled water system
    Yin, P
    Jiang, CX
    PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 1547 - 1554