Neurological Complications and Outcomes in the Berlin Heart EXCOR® Pediatric Investigational Device Exemption Trial

被引:71
|
作者
Jordan, Lori C. [1 ]
Ichord, Rebecca N. [3 ]
Reinhartz, Olaf [4 ]
Humpl, Tilman [5 ]
Pruthi, Sumit [2 ]
Tjossem, Christine [6 ]
Rosenthal, David N. [7 ]
机构
[1] Vanderbilt Univ, Sch Med, Div Pediat Neurol, Dept Pediat, Nashville, TN 37212 USA
[2] Vanderbilt Univ, Sch Med, Dept Radiol, Nashville, TN 37212 USA
[3] Univ Penn, Childrens Hosp Philadelphia, Perelman Sch Med, Dept Neurol, Philadelphia, PA 19104 USA
[4] Stanford Univ, Dept Cardiac Surg, Palo Alto, CA 94304 USA
[5] Hosp Sick Children, Dept Crit Care Med, Toronto, ON M5G 1X8, Canada
[6] Berlin Heart Inc, The Woodlands, TX USA
[7] Stanford Univ, Dept Pediat, Palo Alto, CA 94304 USA
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2015年 / 4卷 / 01期
关键词
heart failure; cardiomyopathy; stroke; pediatrics; VENTRICULAR ASSIST DEVICE; ARTERIAL ISCHEMIC-STROKE; INTERMACS ANNUAL-REPORT; CONTINUOUS-FLOW; CHILDREN; TRANSPLANTATION; SUPPORT; DISEASE;
D O I
10.1161/JAHA.114.001429
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The Berlin Heart EXCOR (R) ventricular assist device has been approved for use in the United States as a bridge to heart transplantation in children. We sought to characterize neurological events in children supported with the Berlin Heart EXCOR (R) device. Methods and Results-The multicenter prospective cohort consisted of all 204 children implanted with the Berlin Heart EXCOR (R) device at 47 centers in North America between May 2007 and December 2010. There were 73 neurological events in 59 patients, with 29% of the cohort experiencing >= 1 neurological event. Events included 52 strokes in 43 patients (21% of the cohort). The neurological event rate was 0.51 events per 100 patient-days. Many of the neurological events occurred early in the course of support, with 30 events recorded during the first 14 days of support. The mortality rate in participants with at least 1 neurological event was 42% (25 of 59), significantly higher than the 18% mortality rate (26 of 145) for those who did not have a neurological event (P=0.0006). Risk-factor analysis did not identify significant preimplantation predictors of neurological injury. Conclusions-Of children treated with the Berlin Heart EXCOR (R) device as a bridge to transplant, 29% experienced at least 1 neurological event. The majority of neurological events were ischemic strokes, and many of those occurred early in the course of support. Neurological injury was the leading cause of death after implantation of the Berlin Heart EXCOR (R) device. Risk stratification for stroke or neurological injury is not possible based on baseline preimplantation characteristics.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] The Berlin Heart EXCOR Pediatric ventricular assist device: history, North American experience, and future directions
    Fraser, Charles D., Jr.
    Jaquiss, Robert D. B.
    PHARMACEUTICAL SCIENCE TO IMPROVE THE HUMAN CONDITION: PRIX GALIEN USA 2012, 2013, 1291 : 96 - 105
  • [32] Anesthesia for noncardiac procedures for children with a Berlin Heart EXCOR® Pediatric Ventricular Assist Device: a case series
    Cave, Dominic A.
    Fry, Kathryn M.
    Buchholz, Holger
    PEDIATRIC ANESTHESIA, 2010, 20 (07) : 647 - 659
  • [33] Upsizing of a Berlin Heart EXCOR pediatric left ventricular assist device to achieve adequate flow requirement
    Orr, Yishay
    Jeewa, Aamir
    McGarry, Mary Claire
    McKenzie, E. Dean
    Adachi, Iki
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (08): : 845 - 846
  • [34] Modified Implantation Technique for the Berlin Heart EXCOR Assist Device in Adults
    Bigdeli, Amir Khosrow
    Michel, Sebastian
    Kaczmarek, Ingo
    Juchem, Gerd
    Ueberfuhr, Peter
    Schmitz, Christoph
    Sodian, Ralf
    ARTIFICIAL ORGANS, 2012, 36 (03) : E48 - E52
  • [35] Infections in patients after Berlin Heart® EXCOR assist device implantation
    Munoz, Patricia
    Valerio, Maricela
    Vasquez, Victor
    Velasquez-Rodriguez, Jesus
    Sousa, Iago
    Zatarain, Eduardo
    Maria Barrio, Jose
    Ruiz, Manuel
    Cuerpo, Gregorio
    Rodriguez-Abella, Hugo
    Hortal, Javier
    Bouza, Emilio
    TRANSPLANT INFECTIOUS DISEASE, 2018, 20 (05)
  • [36] Biventricular Berlin Heart EXCOR Pediatric Use Across the United States
    Zafar, Farhan
    Jefferies, John L.
    Tjossem, Christine J.
    Bryant, Roosevelt, III
    Jaquiss, Robert D. B.
    Wearden, Peter D.
    Rosenthal, David N.
    Cabrera, Antonio G.
    Rossano, Joseph W.
    Humpl, Tilman
    Morales, David L. S.
    ANNALS OF THORACIC SURGERY, 2015, 99 (04): : 1328 - 1334
  • [37] Prospective US investigational device exemption trial of a sutureless aortic bioprosthesis: One-year outcomes
    Suri, Rakesh M.
    Javadikasgari, Hoda
    Heimansohn, David A.
    Weissman, Neil J.
    Ailawadi, Gorav
    Ad, Niv
    Aldea, Gabriel S.
    Thourani, Vinod H.
    Szeto, Wilson Y.
    Michler, Robert E.
    Michelena, Hector I.
    Dabir, Reza
    Fontana, Gregory P.
    Kessler, William F.
    Moront, Michael G.
    Brunsting, Louis A., III
    Griffith, Bartley P.
    Montoya, Alvaro
    Subramanian, Sreekumar
    Mostovych, Mark A.
    Roselli, Eric E.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (05): : 1773 - +
  • [38] Letter by Singh Regarding Article, "Berlin Heart EXCOR Pediatric Ventricular Assist Device for Bridge to Heart Transplantation in US Children"
    Singh, Tajinder P.
    CIRCULATION, 2013, 128 (20) : E405 - E405
  • [39] Modified Technique for the Implantation of Berlin Heart Excor Ventricular Assist Device in Children
    Botha, Phil
    Hasan, Asif
    Perri, Gianluigi
    Filippelli, Sergio
    Griselli, Massimo
    WORLD JOURNAL FOR PEDIATRIC AND CONGENITAL HEART SURGERY, 2012, 3 (03) : 373 - 376
  • [40] Berlin Heart EXCOR Paediatric Ventricular Assist Device: Does Weight Matter?
    Fouilloux, Virginie
    El Louali, Fedoua
    Gran, Celia
    Henaine, Roland
    Roubertie, Francois
    Chenu, Caroline
    Fiorini, Marion
    Le Bel, Stephane
    Mauriat, Philippe
    Neidecker, Jean
    Mace, Loic
    Kreitmann, Bernard
    Ovaert, Caroline
    HEART LUNG AND CIRCULATION, 2021, 30 (04): : 585 - 591