Comparing the Speech Perception of Cochlear Implant Users with Three Different Finnish Speech Intelligibility Tests in Noise

被引:6
|
作者
Willberg, Tytti [1 ,2 ]
Sivonen, Ville [3 ,4 ]
Linder, Pia [5 ]
Dietz, Aarno [5 ]
机构
[1] Turku Univ Hosp, Dept Otorhinolaryngol, Turku 20521, Finland
[2] Univ Eastern Finland, Inst Clin Med, Kuopio 70211, Finland
[3] Helsinki Univ Hosp, Head & Neck Ctr, Dept Otorhinolaryngol Head & Neck Surg, Helsinki 00029, Finland
[4] Univ Helsinki, Helsinki 00029, Finland
[5] Kuopio Univ Hosp, Dept Otorhinolaryngol, Kuopio 70029, Finland
基金
芬兰科学院;
关键词
speech perception; speech perception in noise; cochlear implant; matrix sentence test; digit triplet test; outcomes; adult; hearing loss; audiology; MATRIX SENTENCE TEST; RECOGNITION ABILITIES; NORMAL-HEARING; BKB-SIN; VALIDATION; DIGITS; AGE; RELIABILITY; THRESHOLD; LISTENERS;
D O I
10.3390/jcm10163666
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: A large number of different speech-in-noise (SIN) tests are available for testing cochlear implant (CI) recipients, but few studies have compared the different tests in the same patient population to assess how well their results correlate. Methods: A clinically representative group of 80 CI users conducted the Finnish versions of the matrix sentence test, the simplified matrix sentence test, and the digit triplet test. The results were analyzed for correlations between the different tests and for differences among the participants, including age and device modality. Results: Strong and statistically significant correlations were observed between all of the tests. No floor or ceiling effects were observed with any of the tests when using the adaptive test procedure. Age or the length of device use showed no correlation to SIN perception, but bilateral CI users showed slightly better results in comparison to unilateral or bimodal users. Conclusions: Three SIN tests that differ in length and complexity of the test material provided comparable results in a diverse CI user group.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Cochlear Blood Flow and Speech Perception Ability in Cochlear Implant Users
    Nakashima, Tsutomu
    Hattori, Taku
    Sone, Michihiko
    Asahi, Kiyomitsu
    Matsuda, Naoko
    Teranishi, Masaaki
    Yoshida, Tadao
    Kato, Ken
    Sato, Eisuke
    OTOLOGY & NEUROTOLOGY, 2012, 33 (02) : 165 - 168
  • [32] Comparing Binaural Pre-processing Strategies II: Speech Intelligibility of Bilateral Cochlear Implant Users
    Baumgaertel, Regina M.
    Hu, Hongmei
    Krawczyk-Becker, Martin
    Marquardt, Daniel
    Herzke, Tobias
    Coleman, Graham
    Adiloglu, Kamil
    Bomke, Katrin
    Plotz, Karsten
    Gerkmann, Timo
    Doclo, Simon
    Kollmeier, Birger
    Hohmann, Volker
    Dietz, Mathias
    TRENDS IN HEARING, 2015, 19
  • [33] Effects of a transient noise reduction algorithm on speech intelligibility in noise, noise tolerance and perceived annoyance in cochlear implant users
    Dingemanse, J. Gertjan
    Vroegop, Jantien L.
    Goedegebure, Andre
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2018, 57 (05) : 360 - 369
  • [34] Event-related potentials for better speech perception in noise by cochlear implant users
    Soshi, Takahiro
    Hisanaga, Satoko
    Kodama, Narihiro
    Kanekama, Yori
    Samejima, Yasuhiro
    Yumoto, Eiji
    Sekiyama, Kaoru
    HEARING RESEARCH, 2014, 316 : 110 - 121
  • [35] Are Speech Perception Scores in Cochlear Implant Recipients Consistent Across Different Tests?
    Andresen, Nicholas S.
    Vohra, Varun
    Galaiya, Deepa J.
    Carver, Courtney L.
    Marsiglia, Dawn D.
    Yeagle, Jennifer D.
    Creighton, Francis X.
    Wang, Nae-Yuh
    Bowditch, Stephen P.
    Della Santina, Charles C.
    Sun, Daniel Q.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (07) : E720 - E725
  • [36] The combined effects of reverberation and noise on speech intelligibility by cochlear implant listeners
    Hazrati, Oldooz
    Loizou, Philipos C.
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2012, 51 (06) : 437 - 443
  • [37] Pupillometry and perceived listening effort for cochlear implant users-a comparison of three speech-in-noise tests
    Stronks, Hendrik Christiaan
    Jansen, Paula Louisa
    van Deurzen, Robin
    Briaire, Jeroen Johannes
    Frijns, Johan Hubertus Maria
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2025,
  • [38] Speech Intelligibility for Cochlear Implant Users with the MMSE Noise-Reduction Time-Frequency Mask
    Mourao, Gustavo Leao
    Costa, Marcio Holsbach
    Paul, Stephan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 60 (60)
  • [39] Digisonic® cochlear implant signal processing for speech intelligibility improvement in noise
    Wable, J
    Gallego, S
    Chouard, CH
    Meyer, B
    COCHLEAR IMPLANTS - AN UPDATE, 2002, : 159 - 164
  • [40] PREDICTING THE EFFECT OF AGC ON SPEECH INTELLIGIBILITY OF COCHLEAR IMPLANT RECIPIENTS IN NOISE
    Khing, Phyu P.
    Ambikairajah, Eliathamby
    Swanson, Brett A.
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 8061 - 8065