A technique for 3D in vivo quantification of proton density and magnetization transfer coefficients of knee joint cartilage

被引:31
|
作者
Hohe, J
Faber, S
Stammberger, T
Reiser, M
Englmeier, KH
Eckstein, F
机构
[1] Univ Munich, Inst Anat, Musculoskeletal Res Grp, D-80336 Munich, Germany
[2] GSF Forschungszentrum Umwelt & Gesundheit GMBH, Inst Med Informat & Syst Forsch, D-85764 Oberschleissheim, Germany
[3] Klinikum LMU Munchen Grosshadern, Inst Klin Radiol, D-81377 Munich, Germany
关键词
articular cartilage; proton density; magnetization transfer; magnetic resonance imaging;
D O I
10.1053/joca.1999.0318
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To develop an MR-based method for the in vivo evaluation of the structural composition of articular cartilage. Design: Five sagittal magnetic resonance imaging (MRI) protocols were acquired throughout the knee joint of 15 healthy volunteers and the boundaries of the cartilage segmented from a previously validated sequence with high contrast between cartilage and surrounding tissue. The other sequences were matched to these data, using a 3D least squares fit algorithm to exclude motion artefacts. In this way secondary images were computed that included information about the proton density (interstitial water content) and the magnetization transfer coefficient (macromolecules, collagen). The average signal intensities of the 3D cartilage plates were extracted from these data sets and related to a phantom. Results: The signal intensity data showed a high interindividual variability for the proton density (patella 31%, lateral tibia 36%, medial tibia 29%); the patella displaying higher values than the tibia (P<0.001). There were high correlations between the three plates. The magnetization transfer coefficient also showed high variability (patella 25%, lateral tibia 32%, medial tibia 30%) with the lowest values in the medial tibia (P<0.01) and lower correlations between the plates. The slice-to-slice variation (medial to lateral) ranged from 9% to 24%. Conclusion: An MR-based method has been developed for evaluating the proton density and magnetization transfer of articular cartilage in vivo and observing systematic differences between knee joint cartilage plates. The technique has the potential to supply information about the water content and collagen of articular cartilage, in particular at the early state of osteoarthritic degeneration. (C) 2000 OsteoArthritis Research Society International.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
  • [41] Comparison of Magnetization Transfer Imaging and CPMG for 3D Polymer Gel Dosimetry
    Kubo, H.
    Watanabe, Y.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [42] Diagnostic performance of 3D SPACE for comprehensive knee joint assessment at 3 T
    Pieter Van Dyck
    Jan L. Gielen
    Filip M. Vanhoenacker
    Eline De Smet
    Kristien Wouters
    Lieven Dossche
    Paul M. Parizel
    Insights into Imaging, 2012, 3 (6) : 603 - 610
  • [43] Diagnostic performance of 3D SPACE for comprehensive knee joint assessment at 3 T
    Van Dyck, Pieter
    Gielen, Jan L.
    Vanhoenacker, Filip M.
    De Smet, Eline
    Wouters, Kristien
    Dossche, Lieven
    Parizel, Paul M.
    INSIGHTS INTO IMAGING, 2012, 3 (06): : 603 - 610
  • [44] Magnetization transfer-based 3D visualization of foot peripheral nerves
    Mekle, Ralf
    Mortamet, Benedicte
    Granziera, Cristina
    Krueger, Gunnar
    Chevrey, Nicolas
    Theumann, Nicolas
    Gambarota, Guilio
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 37 (05) : 1234 - 1237
  • [45] 3D magnetization transfer (MT) for the visualization of cardiac free-running Purkinje fibers: an ex vivo proof of concept
    Magat, Julie
    Fouillet, Arnaud
    Constantin, Marion
    Haliot, Kylian
    Naulin, Jerome
    El Hamrani, Dounia
    Benoist, David
    Charron, Sabine
    Walton, Richard
    Bernus, Olivier
    Quesson, Bruno
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2021, 34 (04) : 605 - 618
  • [46] 3D magnetization transfer (MT) for the visualization of cardiac free-running Purkinje fibers: an ex vivo proof of concept
    Julie Magat
    Arnaud Fouillet
    Marion Constantin
    Kylian Haliot
    Jérôme Naulin
    Dounia El Hamrani
    David Benoist
    Sabine Charron
    Richard Walton
    Olivier Bernus
    Bruno Quesson
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2021, 34 : 605 - 618
  • [47] Prospective comparison of 3D FIESTA versus fat-suppressed 3D SPGR MRI in evaluating knee cartilage lesions
    Li, X.
    Yu, C.
    Wu, H.
    Daniel, K.
    Hu, D.
    Xia, L.
    Pan, C.
    Xu, A.
    Hu, J.
    Wang, L.
    Peng, W.
    Li, F.
    CLINICAL RADIOLOGY, 2009, 64 (10) : 1000 - 1008
  • [48] 3D Proton Transfer Augments Bio-Photocurrent Generation
    Rao, Siyuan
    Guo, Zhibin
    Liang, Dawei
    Chen, Deliang
    Li, Yuan
    Xiang, Yan
    ADVANCED MATERIALS, 2015, 27 (16) : 2668 - 2673
  • [49] Study on 3D Model Reconstruction of Human Knee Joint Based on MRI
    Han, Yuemei
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 934 - 937
  • [50] Gesture standardization increases the reproducibility of 3D kinematic measurements of the knee joint
    Lavoie, Frederic
    Laplante, Martin
    Parent, Gerald
    Duval, Nicolas
    Dore, Sylvie
    de Guise, Jacques A.
    CLINICAL BIOMECHANICS, 2006, 21 (05) : 502 - 507