Computation of Alignment and Calibration Constants in CMS

被引:0
|
作者
Mussgiller, A. [1 ]
机构
[1] Deutsch Elekt Synchrotron DESY, Hamburg, Germany
关键词
LHC; CMS; alignment; calibration;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The CMS detector is a very complex apparatus with more than 70 million data acquisition channels. The full physics potential of CMS and the recorded data can only be exploited with precise calibration and alignment constants that have to be produced in an efficient way. The CMS Collaboration has set up an infrastructure for alignment and calibration based on dedicated skimmed data streams providing inputs which are specific to the various workftows computing these constants. A prompt calibration concept allows for the determination of the most time-dependent constants almost immediately after the data are recorded, thus following as fast as possible any change in the running conditions. The paper will introduce the basic concepts of the CMS alignment and calibration infrastructure, and present results from selected workftows.
引用
收藏
页码:1401 / 1403
页数:3
相关论文
共 50 条
  • [41] Development and operational experience of the web based application to collect, manage, and release the alignment and calibration configurations for data processing at CMS
    Md, Hasbuddin
    Kumar, Arun
    Govi, Giacomo
    Franzoni, Giovanni
    Pernie, Luca
    Herland, Sverre
    23RD INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP 2018), 2019, 214
  • [42] Application of the Kalman Alignment Algorithm to the CMS Tracker
    Widl, E.
    Fruehwirth, R.
    17TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP09), 2010, 219
  • [43] Performance test of the CMS link alignment system
    Arce, P
    Calvo, E
    Figueroa, CF
    García, N
    Rodrigo, T
    Vila, I
    Virto, AL
    Barcala, JM
    Fernández, MG
    Ferrando, A
    Josa, MI
    Molinero, A
    Oller, JC
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 492 (03): : 365 - 375
  • [44] Alignment and detection efficiency of CMS Preshower detector
    Tzeng, Yeng-Ming
    35TH INTERNATIONAL CONFERENCE OF HIGH ENERGY PHYSICS (ICHEP 2010), 2010,
  • [45] First test of tiltmeters for the alignment system of CMS
    Berdugo, J
    Burgos, C
    Fernández, MG
    Ferrando, A
    Josa, MI
    Molinero, A
    Oller, JC
    Salicio, JM
    Arce, P
    Calvo, E
    Figueroa, CF
    García, N
    Rodrigo, T
    Vila, I
    Virto, AL
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 431 (03): : 437 - 445
  • [46] CMS Tracker performance and alignment with cosmic muons
    Bonato, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 9 - 13
  • [47] First Alignment of the Complete CMS Silicon Tracker
    Kaschube, Kolja
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1189 - 1193
  • [48] Calibration of the barrel muon drift tubes of CMS
    Mila, Giorgia
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 617 (1-3): : 177 - 179
  • [49] Calibration of the CMS hadron calorimeter in Run 2
    Chadeeva, M.
    Lychkovskaya, N.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [50] DIRECT COMPUTATION OF MADELUNG CONSTANTS
    MIRNIK, M
    CROATICA CHEMICA ACTA, 1986, 59 (02) : 423 - 428