Evaluation of CT-MR image registration methodologies for 3D preoperative planning of forearm surgeries

被引:4
|
作者
Gerber, Nicolas [1 ]
Carrillo, Fabio [2 ]
Abegg, Daniel [2 ]
Sutter, Reto [3 ]
Zheng, Guoyan [4 ]
Fuernstahl, Philipp [2 ]
机构
[1] Univ Bern, Sitem Ctr Translat Med & Biomed Entrepreneurship, Bern, Switzerland
[2] Balgrist Univ Hosp, Res Orthoped Comp Sci, Zurich, Switzerland
[3] Balgrist Univ Hosp, Dept Radiol, Zurich, Switzerland
[4] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai, Peoples R China
关键词
forearm; image-to-image registration; mutual information; surgical planning; DISTAL RADIOULNAR JOINT; CORRECTIVE OSTEOTOMY; RECONSTRUCTION; OPTIMIZATION; ACCURACY; FUSION;
D O I
10.1002/jor.24641
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Computerized surgical planning for forearm procedures that considers both soft and bony tissue, requires alignment of preoperatively acquired computed tomography (CT) and magnetic resonance (MR) images by image registration. Normalized mutual information (NMI) registration techniques have been researched to improve efficiency and to eliminate the user dependency associated with manual alignment. While successfully applied in various medical fields, the application of NMI registration to images of the forearm, for which the relative pose of the radius and ulna likely differs between CT and MR acquisitions, is yet to be described. To enable the alignment of CT and MR forearm data, we propose an NMI-based registration pipeline, which allows manual steering of the registration algorithm to the desired image subregion and is, thus, applicable to the forearm. Successive automated registration is proposed to enable planning incorporating multiple target anatomical structures such as the radius and ulna. With respect to gold-standard manual registration, the proposed registration methodology achieved mean accuracies of 0.08 +/- 0.09 mm (0.01-0.41 mm range) in comparison with 0.28 +/- 0.23 mm (0.03-0.99 mm range) associated with a landmark-based registration when tested on 40 patient data sets. Application of the proposed registration pipeline required less than 10 minutes on average compared with 20 minutes required by the landmark-based registration. The clinical feasibility and relevance of the method were tested on two different clinical applications, a forearm tumor resection and radioulnar joint instability analysis, obtaining accurate and robust CT-MR image alignment for both cases.
引用
收藏
页码:1920 / 1930
页数:11
相关论文
共 50 条
  • [21] Automated Registration of 3D Ultrasound and CT/MR Images for Liver
    Haque, Hasnine
    Omi, Yasuo
    Rusko, Laszlo
    Annangi, Pavan
    Kazuyuki, Ohmura
    2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [22] Dynamic 3D ultrasound and MR image registration of the beating heart
    Huang, XS
    Hill, NA
    Ren, J
    Guiraudon, G
    Boughner, D
    Peters, TM
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2005, PT 2, 2005, 3750 : 171 - 178
  • [23] Accuracy of Pelvic CT-MR Deformable Image Registration: Comparison of Open-Source and Commercial Software
    Ishida, T.
    Kadoya, N.
    Tanabe, S.
    Ohashi, H.
    Nemoto, H.
    Dobashi, S.
    Takeda, K.
    Jingu, K.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [24] How does CT image noise affect 3D deformable image registration for image-guided radiotherapy planning?
    Murphy, Martin J.
    Wei, Zhouping
    Fatyga, Mirek
    Williamson, Jeffrey
    Anscher, Mitchell
    Wallace, Timothy
    Weiss, Elizabeth
    MEDICAL PHYSICS, 2008, 35 (03) : 1145 - 1153
  • [25] Evaluation of Multi-Modality (CT/MR/PET) Image Registration Accuracy in Radiotherapy Planning
    Sethi, A.
    Rusu, I.
    Surucu, M.
    Halama, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3674 - 3675
  • [26] Image-Guided Radiation Therapy: The Accuracy of CT-MR Fusion for Prostate Treatment Planning
    Xue, J.
    Liu, H.
    Chen, X.
    Lin, M.
    Dong, Z.
    Wang, L.
    Chen, L.
    Ma, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [27] Influence of CT-MR image fusion on target volume in irradiation planning for cranial base cancers
    Liesenfeld, S
    Hacker, I
    Wiezorek, T
    Wendt, T
    STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 38 - 38
  • [28] Evaluation of 3D image registration as applied to MR-guided thermal treatment of liver cancer
    Wilson, DL
    Carrillo, A
    Zheng, L
    Genc, A
    Duerk, JL
    Lewin, JS
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01): : 77 - 84
  • [29] Automatic 3D MR Image Registration and Its Evaluation for Precise Monitoring of Knee Joint Disease
    Cheng, Yuanzhi
    Jin, Quan
    Tanaka, Hisashi
    Guo, Changyong
    Ding, Xiaohua
    Tamura, Shinichi
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2011, E94D (03) : 698 - 706
  • [30] Rigid 2D/3D registration of intraoperative digital X-ray images and preoperative CT and MR images
    Tomazevic, D
    Likar, B
    Pernus, F
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 507 - 517