Label-free dynamic light scattering assay for C-reactive protein detection using magnetic nanoparticles

被引:7
|
作者
Antonio, Maria [1 ]
Lima, Tania [2 ,3 ,4 ]
Vitorino, Rui [2 ,5 ,6 ]
Daniel-da-Silva, Ana L. [1 ]
机构
[1] Univ Aveiro, Dept Chem, CICECO Aveiro Inst Mat, P-3810193 Aveiro, Portugal
[2] Univ Aveiro, Dept Med Sci, IBiMED Inst Biomed, P-3810193 Aveiro, Portugal
[3] Portuguese Oncol Inst Porto GEBC CI IPOP, Res Ctr, Canc Biol & Epigenet Grp, P-4200072 Porto, Portugal
[4] Porto Comprehens Canc Ctr PCCC, P-4200072 Porto, Portugal
[5] Univ Porto, Fac Med, Cardiovasc R&D Ctr, Dept Surg & Physiol,UnIC RISE, P-4200319 Porto, Portugal
[6] Univ Aveiro, Chem Dept, LAQV REQUIMTE, Aveiro, Portugal
关键词
Dynamic light scattering; Magnetic nanoparticles; C-reactive protein; Saliva; Detection; IMMUNOASSAY; SALIVARY; MARKERS; RISK;
D O I
10.1016/j.aca.2022.340169
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, we present a simple method for label-free detection of C-reactive protein (CRP) in diluted saliva samples without the use of specific molecules against CRP. We use the dynamic light scattering (DLS) technique and silica-coated Fe3O4 nanoparticles (similar to 50 nm in diameter) functionalized with amino carboxylate moieties (Fe3O4@SiO2/COOH) as probes. After contact with the sample, the particles could be easily separated with a handy magnet and redispersed for DLS analysis simply by vortex shaking. The variation of the hydrodynamic diameter of the nanoparticles (Z-average size) could be correlated with the concentration of CRP up to concentrations of 10 mg L-1. The detection limit (LOD) in diluted saliva samples that were spiked with CRP was 0.205 mg L-1, which is below salivary levels of CRP detected in unhealthy individuals. The coefficient of variation was found to be less than 1.5% in the entire detection range. The variation of Z-average size of nonfunctionalized silica coated nanoparticles (Fe3O4@SiO2) also correlated well with CRP concentration. Nevertheless, the Fe3O4@SiO2/COOH nanoparticles were less susceptible to interference from other biomolecules present in saliva and adsorbed more CRP, indicating higher selectivity toward CRP than nonfunctionalized nanoparticles. This higher affinity was attributed to the chelating interaction between the aminocarboxylate groups of the organosilane N-[3-(trimethoxysilyl)propyl]ethylenediaminetriacetic acid trisodium salt (EDTA-TMS) grafted onto the surface of the Fe3O4@SiO2/COOH nanoparticles and the Ca2+ ions of CRP. LC-MS/MS analyses allowed identification of the proteins adsorbed on the nanoparticles and confirmation of the presence of CRP, which is involved in several biological processes, including immune response, response to stress and transport.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Label-Free Cell Migration Assay Using Magnetic Exclusion
    Gupta, Tamaghna
    Gupta, Rohit
    Dabaghi, Mohammadhossein
    Sahu, Rakesh P.
    Hirota, Jeremy A.
    Puri, Ishwar K.
    ADVANCED MATERIALS TECHNOLOGIES, 2022, 7 (06)
  • [42] A Simple Label-Free Aptamer-Based Electrochemical Biosensor for the Sensitive Detection of C-Reactive Proteins
    Gao, Huilin
    Bai, Yongchang
    He, Baixun
    Tan, Cherie S.
    BIOSENSORS-BASEL, 2022, 12 (12):
  • [43] Functionalized Gold Nanoparticles for the Detection of C-Reactive Protein
    Antonio, Maria
    Nogueira, Joao
    Vitorino, Rui
    Daniel-da-Silva, Ana L.
    NANOMATERIALS, 2018, 8 (04)
  • [44] A simple aptamer-based colorimetric assay for rapid detection of C-reactive protein using gold nanoparticles
    Antonio, Maria
    Ferreira, Rita
    Vitorino, Rui
    Daniel-da-Silva, Ana L.
    TALANTA, 2020, 214
  • [45] Demonstration of a Label-Free and Low-Cost Optical Cavity-Based Biosensor Using Streptavidin and C-Reactive Protein
    Rho, Donggee
    Kim, Seunghyun
    BIOSENSORS-BASEL, 2021, 11 (01):
  • [46] Label-free optical detection of C-reactive protein by nanoimprint lithography-based 2D-photonic crystal film
    Endo, Tatsuro
    Kajita, Hiroshi
    Kawaguchi, Yukio
    Kosaka, Terumasa
    Himi, Toshiyuki
    BIOTECHNOLOGY JOURNAL, 2016, 11 (06) : 831 - 837
  • [47] Label free novel electrical detection using micromachined PZT monolithic thin film cantilever for the detection of C-reactive protein
    Lee, JH
    Yoon, KH
    Hwang, KS
    Park, J
    Ahn, S
    Kim, TS
    BIOSENSORS & BIOELECTRONICS, 2004, 20 (02): : 269 - 275
  • [48] Residual nanoparticle label immunosensor for wash-free C-reactive protein detection in blood
    Huttunen, Roope J.
    Nareoja, Tuomas
    Mariani, Laura
    Harma, Harri
    BIOSENSORS & BIOELECTRONICS, 2016, 83 : 54 - 59
  • [49] Discovering the Unknown: Detection of Emerging Pathogens Using a Label-Free Light-Scattering System
    Rajwa, Bartek
    Dundar, M. Murat
    Akova, Ferit
    Bettasso, Amanda
    Patsekin, Valery
    Hirleman, E. Dan
    Bhunia, Arun K.
    Robinson, J. Paul
    CYTOMETRY PART A, 2010, 77A (12) : 1103 - 1112
  • [50] Use of Magnetic Nanoparticles and a Microplate Reader with Fluorescence Detection to Detect C-reactive Protein
    Yang, Jian-Ying
    Lin, Yi-Jyun
    Su, Mei-Yu
    Li, Wen-Jie
    Liu, Mine-Yine
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2014, 61 (02) : 221 - 226